Please use this identifier to cite or link to this item:
http://dspace.ucuenca.edu.ec/handle/123456789/41990
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.advisor | Sánchez Cordero, Esteban Remigio | - |
dc.contributor.author | Aguilar Gómez, Frank Eduardo | - |
dc.contributor.author | Tenezaca Chimbaina, Marco Vinicio | - |
dc.date.accessioned | 2023-05-31T22:23:08Z | - |
dc.date.available | 2023-05-31T22:23:08Z | - |
dc.date.issued | 2023-05-31 | - |
dc.identifier.uri | http://dspace.ucuenca.edu.ec/handle/123456789/41990 | - |
dc.description | El propósito de este estudio fue analizar la eficiencia hidráulica de la red de distribución de agua potable de la parroquia Bayas, perteneciente al cantón Azogues, proporcionando un diagnóstico del sistema actual y las propuestas de mejoras haciendo uso de la herramienta computacional Epanet. Se realizó una actualización de los datos geométrico – hidráulicos de la red existente, con la que se pudo evaluar el funcionamiento hidráulico. Se consideró el efecto en las variables hidráulicas de presión y velocidad cuando se incorpora un nuevo tanque de almacenamiento. Según el diagnóstico del sistema sin la incorporación del nuevo tanque, el 47.00 % de los nodos de toda la red superaron el límite de presión máxima establecida mientras que, en las zonas ramificadas de la red predominaron velocidades bajas en un 64.80 % de tuberías; así mismo se determinó que, con la simulación del nuevo tanque, persisten estos dos problemas. Se estudiaron tres propuestas de mejora para la optimización; la primera fue la incorporación de válvulas reductoras de presión en puntos estratégicos de la red, lo que permitió una mejora del 32 % en las presiones del sistema. La segunda fue el desarrollo de un algoritmo para hallar diámetros óptimos en la red, este fue implementado a través de la Toolkit de Epanet, obteniendo una mejora del 34 % y 5 % en las presiones y velocidades, respectivamente. La última propuesta estudiada consistió en la creación de circuitos cerrados, con esto se obtuvo una mejora del 8 % en las velocidades del sistema. | en_US |
dc.description.abstract | The purpose of this study was to analyze the hydraulic efficiency of the drinking water distribution network of the parish of Bayas belonging to the canton Azogues and provide a diagnosis of the current system and proposals for improvements by making use of the computational tool Epanet. An update of the geometric - hydraulic data of the existing network was made, with which the hydraulic performance could be evaluated. The effect of hydraulic variables (pressure and velocity) was considered when a new storage tank was incorporated. According to the diagnosis of the system without the incorporation of the new tank, 47.00% of the nodes of the entire network exceeded the maximum pressure limit established while in the branched areas of the network low speeds predominated in 64.80% of pipes. It was also determined that, with the simulation of the new tank these two problems persist. Three improvement proposals for optimization were considered; the first was the incorporation of pressure reducing valves at strategic points in the network, which allowed a 32% improvement in system pressures. The second was the development of an algorithm to find optimal diameters in the network; it was implemented through the Epanet Toolkit, obtaining an improvement of 34% and 5% in pressures and speeds respectively. The last proposal studied consisted of the creation of closed circuits, which resulted in an 8% improvement in system speeds. | en_US |
dc.description.uri | 0000-0002-8206-386X | en_US |
dc.description.uri | 0000-0002-9274-9769 | en_US |
dc.format | application/pdf | en_US |
dc.format.extent | 190 páginas | en_US |
dc.language.iso | spa | en_US |
dc.publisher | Universdidad de Cuenca | en_US |
dc.relation.ispartof | TI;1288 | - |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.subject | Ingeniería Civil | en_US |
dc.subject | Agua potable | en_US |
dc.subject | Distribución acuática | en_US |
dc.subject.other | CIUC::Ingenierías::Ingeniería Sanitaria::Redes de Suministro de Agua | en_US |
dc.title | Análisis de la eficiencia hidráulica de la red de distribución de agua potable de la parroquia Bayas perteneciente al cantón Azogues - Diagnóstico del sistema actual y propuesta de mejoras | en_US |
dc.contributor.tutor | García Ávila, Fausto Fernando | - |
dcterms.description | Ingeniero Civil | en_US |
dcterms.spatial | Cuenca | en_US |
dc.rights.accessRights | openAccess | en_US |
Appears in Collections: | Tesis de Pregrado |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Trabajo-de-Titulación.pdf | Versión presentada (texto completo) | 7.19 MB | Adobe PDF | View/Open |
This item is protected by original copyright |
This item is licensed under a Creative Commons License
Centro de Documentacion Regional "Juan Bautista Vázquez" | ||||||||||
|