Título : Assessment model of energy performance in housing of Cuenca, Ecuador
Autor: Guillen Mena, Vanessa Fernanda
Quesada Molina, Juan Felipe
Correspondencia: Guillen Mena, Vanessa Fernanda, vanessa.guillen@ucuenca.edu.ec
Palabras clave : Energy indicators
Sustainable building assessment
Dwellings
Ecuador
Building energy performance
Área de conocimiento FRASCATI amplio: 2. Ingeniería y Tecnología
Área de conocimiento FRASCATI detallado: 2.2.1 Ingeniería Eléctrica y Electrónica
Área de conocimiento FRASCATI específico: 2.2 Ingenierias Eléctrica, Electrónica e Información
Área de conocimiento UNESCO amplio: 07 - Ingeniería, Industria y Construcción
ÁArea de conocimiento UNESCO detallado: 0713 - Electricidad y Energia
Área de conocimiento UNESCO específico: 071 - Ingeniería y Profesiones Afines
Fecha de publicación : 2019
Volumen: Volumen 10, Numero 4
Fuente: Ain Shams Engineering Journal
metadata.dc.identifier.doi: 10.1016/j.asej.2019.03.010
Tipo: ARTÍCULO
Abstract: 
Abstract This study investigates residential energy consumption in Cuenca, Ecuador, to develop a model to assess the energy performance of homes contextualized to the local reality. The research methodology is based on an analysis of international sustainability certification methods, case studies of the locality, and the participation of experts. The results determine an assessment model of energy performance composed of seven requirements with eleven evaluation criteria for multi-family dwellings, and six requirements with nine evaluation criteria for single-family homes. Three levels of compliance were defined for each evaluation criterion: standard, best, and superior practice. To meet the standard practice, for the use of such things as heating, cooling, lighting, equipment, and appliance indicators, energy usage must fall within a range of 30.1 kWh/m 2 per year to 41.6 kWh/m 2 per year; superior practice values must not be>24.3 kWh/m 2 per year.
Resumen : 
This study investigates residential energy consumption in Cuenca, Ecuador, to develop a model to assess the energy performance of homes contextualized to the local reality. The research methodology is based on an analysis of international sustainability certification methods, case studies of the locality, and the participation of experts. The results determine an assessment model of energy performance composed of seven requirements with eleven evaluation criteria for multi-family dwellings, and six requirements with nine evaluation criteria for single-family homes. Three levels of compliance were defined for each evaluation criterion: standard, best, and superior practice. To meet the standard practice, for the use of such things as heating, cooling, lighting, equipment, and appliance indicators, energy usage must fall within a range of 30.1 kWh/m 2 per year to 41.6 kWh/m 2 per year; superior practice values must not be>24.3 kWh/m 2 per year.
URI : http://dspace.ucuenca.edu.ec/handle/123456789/34344
https://www.sciencedirect.com/science/article/pii/S2090447919300644
URI Fuente: https://www.sciencedirect.com/journal/ain-shams-engineering-journal/vol/10/issue/4
ISSN : 2090-4479
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
documento.pdfdocument2.02 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está protegido por copyright original



Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00