Logo Repositorio Institucional

Please use this identifier to cite or link to this item: http://dspace.ucuenca.edu.ec/handle/123456789/34344
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGuillen Mena, Vanessa Fernanda-
dc.contributor.authorQuesada Molina, Juan Felipe-
dc.date.accessioned2020-05-19T22:39:43Z-
dc.date.available2020-05-19T22:39:43Z-
dc.date.issued2019-
dc.identifier.issn2090-4479-
dc.identifier.urihttp://dspace.ucuenca.edu.ec/handle/123456789/34344-
dc.identifier.urihttps://www.sciencedirect.com/science/article/pii/S2090447919300644-
dc.descriptionThis study investigates residential energy consumption in Cuenca, Ecuador, to develop a model to assess the energy performance of homes contextualized to the local reality. The research methodology is based on an analysis of international sustainability certification methods, case studies of the locality, and the participation of experts. The results determine an assessment model of energy performance composed of seven requirements with eleven evaluation criteria for multi-family dwellings, and six requirements with nine evaluation criteria for single-family homes. Three levels of compliance were defined for each evaluation criterion: standard, best, and superior practice. To meet the standard practice, for the use of such things as heating, cooling, lighting, equipment, and appliance indicators, energy usage must fall within a range of 30.1 kWh/m 2 per year to 41.6 kWh/m 2 per year; superior practice values must not be>24.3 kWh/m 2 per year.-
dc.description.abstractAbstract This study investigates residential energy consumption in Cuenca, Ecuador, to develop a model to assess the energy performance of homes contextualized to the local reality. The research methodology is based on an analysis of international sustainability certification methods, case studies of the locality, and the participation of experts. The results determine an assessment model of energy performance composed of seven requirements with eleven evaluation criteria for multi-family dwellings, and six requirements with nine evaluation criteria for single-family homes. Three levels of compliance were defined for each evaluation criterion: standard, best, and superior practice. To meet the standard practice, for the use of such things as heating, cooling, lighting, equipment, and appliance indicators, energy usage must fall within a range of 30.1 kWh/m 2 per year to 41.6 kWh/m 2 per year; superior practice values must not be>24.3 kWh/m 2 per year.-
dc.language.isoes_ES-
dc.sourceAin Shams Engineering Journal-
dc.subjectEnergy indicators-
dc.subjectSustainable building assessment-
dc.subjectDwellings-
dc.subjectEcuador-
dc.subjectBuilding energy performance-
dc.titleAssessment model of energy performance in housing of Cuenca, Ecuador-
dc.typeARTÍCULO-
dc.ucuenca.idautor0102260148-
dc.ucuenca.idautor0104436357-
dc.identifier.doi10.1016/j.asej.2019.03.010-
dc.ucuenca.versionVersión publicada-
dc.ucuenca.areaconocimientounescoamplio07 - Ingeniería, Industria y Construcción-
dc.ucuenca.afiliacionGuillen, V., Universidad de Cuenca, Facultad de Arquitectura y Urbanismo, Cuenca, Ecuador-
dc.ucuenca.afiliacionQuesada, J., Universidad de Cuenca, Facultad de Arquitectura y Urbanismo, Cuenca, Ecuador-
dc.ucuenca.correspondenciaGuillen Mena, Vanessa Fernanda, vanessa.guillen@ucuenca.edu.ec-
dc.ucuenca.volumenVolumen 10, Numero 4-
dc.ucuenca.indicebibliograficoSCOPUS-
dc.ucuenca.factorimpacto0.47-
dc.ucuenca.cuartilQ1-
dc.ucuenca.numerocitaciones0-
dc.ucuenca.areaconocimientofrascatiamplio2. Ingeniería y Tecnología-
dc.ucuenca.areaconocimientofrascatiespecifico2.2 Ingenierias Eléctrica, Electrónica e Información-
dc.ucuenca.areaconocimientofrascatidetallado2.2.1 Ingeniería Eléctrica y Electrónica-
dc.ucuenca.areaconocimientounescoespecifico071 - Ingeniería y Profesiones Afines-
dc.ucuenca.areaconocimientounescodetallado0713 - Electricidad y Energia-
dc.ucuenca.urifuentehttps://www.sciencedirect.com/journal/ain-shams-engineering-journal/vol/10/issue/4-
Appears in Collections:Artículos

Files in This Item:
File Description SizeFormat 
documento.pdfdocument2.02 MBAdobe PDFThumbnail
View/Open


This item is protected by original copyright



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00