Title: Assessment model of energy performance in housing of Cuenca, Ecuador
Authors: Guillen Mena, Vanessa Fernanda
Quesada Molina, Juan Felipe
metadata.dc.ucuenca.correspondencia: Guillen Mena, Vanessa Fernanda, vanessa.guillen@ucuenca.edu.ec
Keywords: Energy indicators
Sustainable building assessment
Dwellings
Ecuador
Building energy performance
metadata.dc.ucuenca.areaconocimientofrascatiamplio: 2. Ingeniería y Tecnología
metadata.dc.ucuenca.areaconocimientofrascatidetallado: 2.2.1 Ingeniería Eléctrica y Electrónica
metadata.dc.ucuenca.areaconocimientofrascatiespecifico: 2.2 Ingenierias Eléctrica, Electrónica e Información
metadata.dc.ucuenca.areaconocimientounescoamplio: 07 - Ingeniería, Industria y Construcción
metadata.dc.ucuenca.areaconocimientounescodetallado: 0713 - Electricidad y Energia
metadata.dc.ucuenca.areaconocimientounescoespecifico: 071 - Ingeniería y Profesiones Afines
Issue Date: 2019
metadata.dc.ucuenca.volumen: Volumen 10, Numero 4
metadata.dc.source: Ain Shams Engineering Journal
metadata.dc.identifier.doi: 10.1016/j.asej.2019.03.010
metadata.dc.type: ARTÍCULO
Abstract: 
Abstract This study investigates residential energy consumption in Cuenca, Ecuador, to develop a model to assess the energy performance of homes contextualized to the local reality. The research methodology is based on an analysis of international sustainability certification methods, case studies of the locality, and the participation of experts. The results determine an assessment model of energy performance composed of seven requirements with eleven evaluation criteria for multi-family dwellings, and six requirements with nine evaluation criteria for single-family homes. Three levels of compliance were defined for each evaluation criterion: standard, best, and superior practice. To meet the standard practice, for the use of such things as heating, cooling, lighting, equipment, and appliance indicators, energy usage must fall within a range of 30.1 kWh/m 2 per year to 41.6 kWh/m 2 per year; superior practice values must not be>24.3 kWh/m 2 per year.
Description: 
This study investigates residential energy consumption in Cuenca, Ecuador, to develop a model to assess the energy performance of homes contextualized to the local reality. The research methodology is based on an analysis of international sustainability certification methods, case studies of the locality, and the participation of experts. The results determine an assessment model of energy performance composed of seven requirements with eleven evaluation criteria for multi-family dwellings, and six requirements with nine evaluation criteria for single-family homes. Three levels of compliance were defined for each evaluation criterion: standard, best, and superior practice. To meet the standard practice, for the use of such things as heating, cooling, lighting, equipment, and appliance indicators, energy usage must fall within a range of 30.1 kWh/m 2 per year to 41.6 kWh/m 2 per year; superior practice values must not be>24.3 kWh/m 2 per year.
URI: http://dspace.ucuenca.edu.ec/handle/123456789/34344
https://www.sciencedirect.com/science/article/pii/S2090447919300644
metadata.dc.ucuenca.urifuente: https://www.sciencedirect.com/journal/ain-shams-engineering-journal/vol/10/issue/4
ISSN: 2090-4479
Appears in Collections:Artículos

Files in This Item:
File Description SizeFormat 
documento.pdfdocument2.02 MBAdobe PDFThumbnail
View/Open


This item is protected by original copyright



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00