Logo Repositorio Institucional

Please use this identifier to cite or link to this item: http://dspace.ucuenca.edu.ec/handle/123456789/30349
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorJiménez Pacheco, Juan Carlos-
dc.contributor.authorQuinde Viñansaca, John Alejandro-
dc.contributor.authorRea Orellana, William Fernando-
dc.date.accessioned2018-05-09T21:33:36Z-
dc.date.available2018-05-09T21:33:36Z-
dc.date.issued2018-
dc.identifier.urihttp://dspace.ucuenca.edu.ec/handle/123456789/30349-
dc.descriptionLas edificaciones construidas en la década de los 80’s en Cuenca, con deficiencias de diseño debido a falta de fiscalización, son susceptibles a falla por cortante en sus elementos durante un sismo, siendo un problema crítico cuando esta se produce en columnas. Debido al número importante de estas edificaciones en la ciudad, en el presente trabajo se determina su capacidad y evalúa su desempeño sísmico mediante métodos actuales de análisis sísmico estático no lineal. Para esto se considera un edificio aporticado de hormigón armado representativo de la ciudad, de 4 pisos, con detallado del refuerzo en vigas y columnas de acuerdo a las tendencias y criterios constructivos de la época. El desempeño se determina mediante el Método del Espectro de Capacidad propuesto por el manual FEMA 440, el cual parte de la curva de capacidad de la estructura obtenida mediante un análisis estático no lineal que incluye la modelización del cortante, y del espectro de respuesta de la zona de estudio. Los resultados obtenidos son: la capacidad y el punto de desempeño sísmico para 3 casos representativos de la época obtenidos de información histórica. Además, se demuestra el aporte del refuerzo transversal correctamente detallado a la ductilidad de la estructura a partir de un análisis paramétrico que considera como variables la separación y el diámetro del refuerzo transversal en vigas y columnas. Finalmente, se realizó una estimación del daño que sufrirá la estructura mediante los umbrales de daño propuestos en el proyecto de la Comisión Europea RISK-UE.es_ES
dc.description.abstractThe buildings constructed in the 80's in Cuenca, with design deficiencies due to lack of control, are susceptible to shear failure in their elements during an earthquake, being a critical problem when it occurs in columns. Due to the important number of these buildings in the city, in the present work their capacity is determined and their seismic performance is evaluated by means of current nonlinear static seismic analysis methods. For this, it is considered a 4-story reinforced concrete building representative of the city, with detailing of reinforcement in beams and columns according to the trends and constructive criteria of the time. The performance is determined by the Capacity Spectrum Method proposed by the FEMA 440 manual, which starts from the capacity curve of the structure obtained by a non-linear static analysis that includes the shear modeling, and the response spectrum of the study zone. The results obtained are: the capacity and the point of seismic performance for 3 representative cases of the epoch obtained from historical information. In addition, the contribution of the transversal reinforcement correctly detailed to the ductility of the structure is demonstrated from a parametric analysis that considers as variables the separation and the diameter of the transversal reinforcement in beams and columns. Finally, an estimate was made of the damage that the structure will suffer through the damage thresholds proposed in the project of the European Commission RISK-EU.es_ES
dc.formatapplication/pdfes_ES
dc.language.isospaes_ES
dc.subjectAnalisis Pushoveres_ES
dc.subjectRuaumokoes_ES
dc.subjectFalla Por Cortantees_ES
dc.subjectMetodo Del Espectro De Capacidades_ES
dc.subjectPunto De Desempeñoes_ES
dc.titleEvaluación sísmica de edificios aporticados de hormigón armado con deficiencias de diseño, mediante el método del espectro de capacidad FEMA 440es_ES
dc.typebachelorThesises_ES
dc.ucuenca.paginacion129 páginases_ES
dc.description.degreeIngeniero Civiles_ES
dc.description.cityCuencaes_ES
dc.ucuenca.id0102260965es_ES
dc.ucuenca.idautor0105344956es_ES
dc.ucuenca.idautor0105742811es_ES
Appears in Collections:Tesis de Pregrado

Files in This Item:
File Description SizeFormat 
Trabajo de titulación.pdftexto completo4.79 MBAdobe PDFThumbnail
View/Open


This item is protected by original copyright



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00