dc.description.abstractHeart rate variability (HRV) is a simple, non-invasive measure that can be used to quantify autonomic nervous system modulation. This method has been used to detect alterations of autonomic cardiovascular regulation in diabetes and metabolic syndrome (MetS). MetS is characterized by the clustering of glucose intolerance, central obesity, dyslipidemia, and hypertension. This study analyze the HRV using nonlinear methods, in three study groups: 15 subjects with MetS, 10 subjects for control group (C), 15 subjects athletes (D), belonging to a data base with electrocardiographic signals during the test oral glucose tolerance (OGTT). In order to characterize the study groups, two analyzes were performed, one statistical to find significant differences, and a simple correspondence analysis. In the obtained results, significant differences were observed (p < 0.05-Wilcoxon) between MetS and C groups at the baseline phase in the index average descriptor de Poincaré (SD2) (76.368 ± 26.511ms versus 102.546 ± 35.706ms) and entropy approximate (ApEn) (1.220 ± 0.089 versus 1.307 ± 0.116). The simple correspondence took into account two components representing 59.19% of the total variance, and these components suggests that the descriptor de Poincare (SD1) and correlation dimension (D2) parameters can discriminate between groups. The results suggest that nonlinear parameters SD1, SD2, ApEn and D2, show that the heart rate dynamics and the regularity of the HRV are affected in subjects with MetS.
dc.description.cityBucaramanga
dc.identifier.doi10.1109/STSIVA.2016.7743303
dc.identifier.isbn9781509037971
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85002681884&doi=10.1109%2fSTSIVA.2016.7743303&partnerID=40&md5=0f08c52cbb18ec1592fc1fbd57cb73d4
dc.identifier.urihttp://dspace.ucuenca.edu.ec/handle/123456789/29097
dc.language.isoen_US
dc.publisherINSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS INC.
dc.source2016 21st Symposium on Signal Processing, Images and Artificial Vision, STSIVA 2016
dc.titleNonlinear parameters of heart rate variability during oral glucose tolerance test
dc.typeArticle
dc.ucuenca.afiliacionwong, s., prometeo resercher, deet, university of cuenca, cuenca, ecuador
dc.ucuenca.embargoend2022-01-01 0:00
dc.ucuenca.idautor081929618
dc.ucuenca.indicebibliograficoSCOPUS
dc.ucuenca.nombrerevista21st Symposium on Signal Processing Images and Artificial Vision STSIVA 2016

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
documento.pdf
Size:
168.92 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
19.94 KB
Format:
Plain Text
Description:

Collections