Dosis de efectividad de radiación utilizada en estudios de cráneo, cuello, tórax y abdomen con un tomógrafo multicorte de 64 canales en el Hospital José Carrasco Arteaga Cuenca, septiembre del 2014-febrero del 2015

dc.contributor.advisorOrtiz Sagba, Nelson Ramiro
dc.contributor.assessorFreire Argudo, Marco Vinicio
dc.contributor.authorMontenegro Córdova, Andrea Cristina
dc.contributor.authorToalón Idrovo, Henry Paúl
dc.date.accessioned2015-03-31T21:52:04Z
dc.date.available2015-03-31T21:52:04Z
dc.date.issued2015
dc.descriptionLa tomografía computarizada multicorte TCM ha permitiendo grandes avances en el diagnóstico no invasivo de varias enfermedades. En la actualidad la mayor parte de la radiación aplicada surge del uso de la TC, seguido de la medicina nuclear y la fluroscopia. El objetivo de nuestra investigación estuvo en determinar la dosis efectiva en estudios de cráneo, cuello, tórax y abdomen con un Tomógrafo Multicorte de 64 canales en el Hospital ¨José Carrasco Arteaga¨ en el catón Cuenca, durante el período de septiembre-febrero del 2014-2015. Se estudiaron 3129 casos con una media de edad de 48,58 años con el grupo de edad más numeroso en pacientes de 16 años y más con el 90,3%; el sexo más frecuente fue el femenino con el 50,5%.Se estudiaron 4 tipos de procedimientos tomográficos, siendo la de cráneo la más frecuente con el 68,1%, y la de cuello el menos frecuente con el 1%. La dosis efectiva máxima utilizada fue de 21,98mSv en el grupo de 16 años y más y la mínima de 0,38mSv en los estudios de cráneo del mismo grupo. La dosis efectiva en todas las tomografías sin contraste en el grupo de 16 años y más no superó los niveles de referencia. El valor de la dosis efectiva en todas las tomografías con contraste en el grupo de 16 años y más superó los niveles de referencia. Debido a que no se encontraron niveles de referencia de dosis efectiva para los grupos pediátricos, se estudió la DLP encontrándose niveles superiores en los primeros grupos de edad. Los resultados adquiridos en el presente trabajo de investigación se difundirán en la revista de la Facultad de Ciencias Médicas de la Universidad de Cuenca y servirá como base de estudio para futuras comparaciones.es_ES
dc.description.abstractComputed tomography allowing TCM has great advances in noninvasive diagnosis of various diseases. At present most of the applied radiation arises from the use of CT, followed by nuclear medicine and fluoroscopy. The aim of our research was to determine the effective dose in studies of skull, neck, thorax and abdomen with a 64-channel Multislice Tomography in Arteaga's José Carrasco Hospital in Cuenca Cato, during the period from September to February 2014 -2015. 3129 cases with a mean age of 48.58 years with the largest age group in patients 16 years and older with 90.3% were studied; the most common female sex was 50.5%. 4 types of tomographic methods were studied, being the most frequent with 68.1% skull and neck less frequent with 1%. The maximum effective dose used was 21,98mSv in the group of 16 years or more and the minimum 0,38mSv in studies of the skull of the same group. The effective dose in all CT without contrast in the group aged 16 and over did not exceed baseline levels. The value of the effective dose in all CT with contrast in the group aged 16 years and over exceeded baseline levels. Because no reference levels effective dose for pediatric groups found, the DLP was studied found higher levels in the first age group. The results obtained in this research will be disseminated in the Journal of the Faculty of Medicine of the University of Cuenca and study serve as a basis for future comparisons.es_ES
dc.description.cityCuencaes_ES
dc.description.degreeLicenciada y Licenciado en Imagenologíaes_ES
dc.formatapplication/pdfes_ES
dc.identifier.urihttp://dspace.ucuenca.edu.ec/handle/123456789/21562
dc.language.isospaes_ES
dc.relation.ispartofseriesTECI;054
dc.rightsopenAccess
dc.rights.urihttp://creativecommons.org/licenses/by-nc-sa/3.0/ec/
dc.subjectRadiaciones_ES
dc.subjectTomografia Computarizadaes_ES
dc.subjectTomografo Multicortees_ES
dc.subjectProteccion Radiologicaes_ES
dc.titleDosis de efectividad de radiación utilizada en estudios de cráneo, cuello, tórax y abdomen con un tomógrafo multicorte de 64 canales en el Hospital José Carrasco Arteaga Cuenca, septiembre del 2014-febrero del 2015es_ES
dc.typebachelorThesises_ES
dc.ucuenca.id0602727455es_ES
dc.ucuenca.idautor0105680557es_ES
dc.ucuenca.idautor1400477269es_ES
dc.ucuenca.paginacion63 páginases_ES

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Tesis.pdf
Size:
4.45 MB
Format:
Adobe Portable Document Format
Description:

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
19.88 KB
Format:
Item-specific license agreed upon to submission
Description: