Caracterización morfológica del periodo gestacional de cobayas in vivo y post mortem mediante ultrasonografía

dc.contributor.advisorGaray Peña, Gabriela Sofía
dc.contributor.authorGañán Cornejo, Gissela Eugenia
dc.contributor.authorMunzón Guallpa, Fernanda Estefanía
dc.date.accessioned2025-02-07T13:58:40Z
dc.date.available2025-02-07T13:58:40Z
dc.date.issued2025-02-06
dc.descriptionEl estudio evaluó in vivo y post mortem el desarrollo morfoestructural del feto y la placenta durante el periodo gestacional. Se utilizaron 35 cobayas hembras y 12 machos de línea peruana que fueron obtenidas de una sola granja comercial ubicada en Santa Ana, Cuenca, Ecuador. En primera instancia se usó la ultrasonografía (US) en animales gestantes in vivo y post mortem. En un segundo momento a través de un calibrador se tomaron las mismas variables post mortem. Se determinó mediante US in vivo el diámetro biparietal “DBP”; diámetro de abdomen “DA”; diámetro de tórax “DT”; longitud cráneo caudal “LCC”; frecuencia cardiaca “FC”; diámetro de placenta “DP”; diámetro del saco gestacional “DSG”, en los días 15, 20, 25, 30, 35, 40, 45, 50, 55 y 60 de gestación. En la valoración de los días 15, 20, 25, 30 y 35 luego de la US las cobayas fueron eutanasiadas y se procedió a valorar post mortem mediante US las mismas variables. A continuación, se tomaron mediadas de esas variables mediante un calibrador; además, se determinó la concentración de progesterona (P4). Mediante la administración de P4 oral se logró que un 83% de cobayas entraran en celo. Se determinó que la US realizada in vivo permite obtener medidas similares del DP y del DSG a las determinadas post mortem mediante el uso del calibrador. El DBP es la variable que mayor uniformidad proporcionó al usar las tres formas de medida. El DA, el DT y la LCC obtenido mediante US in vivo mostraron variaciones estadísticas (P<0,05) frente a las valoraciones con US post mortem y con los valores obtenidos con el calibrador por lo que no se considera una medida confiable. La FC se mostró estable y similar (P>0,05) durante los diferentes monitoreos realizados. La P4 mostró un valor elevado en el día 15, luego disminuyó al día 20 y estos valores se mantuvieron hasta el día 25; sin embargo, a partir del día 30 se volvió a ver un incremento llegando a duplicar los valores de P4 en el día 35 de gestación. Se concluye que el diagnóstico con US tiene alta confiabilidad al visualizar la placenta y el saco gestacional y que el DBP se constituye en la mejor medida para relacionar la edad gestacional en la cobaya.
dc.description.abstractThe research was conducted at a commercial farm in Santa Ana, Cuenca, Ecuador, involving 35 female guinea pigs and 12 males of the Peruvian line. The study aimed to evaluate the morpho-structural development of the fetus and placenta during the gestational period, both in vivo and post mortem. In the first phase, ultrasonography (US) was used to measure variables in pregnant animals both in vivo and post-mortem. Subsequently, the same variables were evaluated post-mortem using a caliper. In vivo US measurements included biparietal diameter (BPD), abdominal diameter (AD), thoracic diameter (TD), caudal skull length (CCL), heart rate (HR), placental diameter (PD), and gestational sac diameter (GSD), assessed on days 15, 20, 25, 30, 35, 40, 45, 50, 55, and 60 of gestation. On days 15, 20, 25, 30, and 35, after in vivo US evaluation, the guinea pigs were euthanized to analyze the same variables post-mortem using both US and the caliper. Additionally, progesterone (P4) levels were measured. Through oral P4 administration, estrus was successfully induced in 83% of the guinea pigs. The results showed that in vivo US provided reliable measurements of PD and GSD, comparable to those obtained post-mortem using the caliper. Furthermore, BPD was identified as the most consistent variable when comparing the three measurement methods. However, AD, TD, and CCL showed statistically significant variations (P<0.05) between in vivo and post-mortem measurements, limiting their reliability. HR remained stable and showed no significant differences (P>0.05) during the monitoring periods. Regarding P4 levels, an increase was observed on day 15, followed by a decrease by on day 20. These levels remained steady until day 25, increasing again from day 30 and doubling by day 35 of gestation. It is concluded that in vivo ultrasonography is a highly reliable tool for visualizing the placenta and gestational sac, with BPD being the best measure to estimate gestational age in guinea pigs.
dc.description.uri0000-0002-9519-5554
dc.formatapplication/pdf
dc.format.extent91 páginas
dc.identifier.urihttps://dspace.ucuenca.edu.ec/handle/123456789/45965
dc.language.isospa
dc.publisherUniversidad de Cuenca
dc.relation.ispartofTV; 544
dc.rightshttps://creativecommons.org/licenses/by-nd/4.0
dc.rights.accessRightsopenAccess
dc.subjectMedicina Veterinaria
dc.subjectCobayas
dc.subjectReproducción animal
dc.subjectFecundación
dc.subject.otherVETERINARY MEDICINE
dc.titleCaracterización morfológica del periodo gestacional de cobayas in vivo y post mortem mediante ultrasonografía
dc.typesubmittedVersion
dcterms.descriptionMédico Veterinario
dcterms.spatialCuenca, Ecuador

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Trabajo-de-Titulación.pdf
Size:
2.4 MB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: