| dc.description | La resistencia a la fractura de coronas atornilladas sobre implantes es un factor determinantepara el éxito clínico a largo plazo de las restauraciones dentales. Este estudio, realizado entre 2023 y 2024, tuvo como objetivo evaluar la resistencia a la fractura y el modo de fallo decoronas elaboradas con resina impresa en 3D y zirconio, utilizando pilares de titanio de dosalturas (4 mm y 6 mm). Se fabricaron 40 coronas, distribuidas en cuatro grupos de 10muestras: grupo 1 (resina + pilar de 4 mm), grupo 2 (resina + pilar de 6 mm), grupo 3 (zirconio+ pilar de 4 mm) y grupo 4 (zirconio + pilar de 6 mm). Todas fueron sometidas a pruebas decarga hasta la fractura, y los resultados fueron analizados estadísticamente mediante laprueba t de Student y distribución de Weibull. Se observó que las coronas de zirconiomostraron una resistencia significativamente mayor que las de resina 3D (p < 0,001). El grupo4 presentó la mayor resistencia (media: 940,711 N ± 28,147), mientras que el grupo 1 mostróla menor (media: 282,912 N ± 41,351). Además, el módulo de Weibull más alto correspondióal grupo 4 (m = 30.812), indicando una mayor confiabilidad. En conclusión, ambas opcionesde material superaron los límites de carga fisiológica, pero se recomienda el uso de pilaresmás largos, especialmente para coronas de resina 3D, debido a su mejor comportamientomecánico en combinación con bases de mayor altura. | |
| dc.description.abstract | The fracture resistance of screw-retained implant-supported crowns is critical for the long-term success of dental restorations, and both abutment design and material cansignificantly influence their mechanical performance. This study, conducted during 2023–2024, aimed to evaluate the fracture resistance and failure modes of crowns made from 3D-printed resin and zirconia mounted on titanium abutments of two heights: 4 mm (short) and 6mm (long). Forty crowns were fabricated and divided into four groups: Group 1 (resin on 4 mmabutments), Group 2 (resin on 6 mm abutments), Group 3 (zirconia on 4 mm abutments), andGroup 4 (zirconia on 6 mm abutments). All specimens underwent fracture resistance testing,and results were analyzed using the Student’s t-test. Zirconia crowns showed significantlyhigher fracture resistance than 3D-printed resin crowns (p < 0.001), with Group 4 (zirconia +6 mm abutment) displaying the highest mean fracture strength (940.711 N ± 28.147), whileGroup 1 (resin + 4 mm abutment) had the lowest (282.912 N ± 41.351). F values of 1257.725and 2777.538 for the 4 mm and 6 mm abutments, respectively, confirmed the statisticalsignificance. Additionally, the Weibull analysis indicated greater reliability in zirconia crowns,particularly in Group 4, which showed the highest Weibull modulus (m = 30.812), reflectingsuperior structural stability. In conclusion, both zirconia and 3D-printed resin crowns exceededphysiological load thresholds, confirming their suitability for implant-supported anteriorrestorations. However, longer abutments are especially recommended for resin crowns tooptimize fracture resistance and overall performance. | |
| dc.description.uri | 0000-0003-2347-8464 | |
| dc.format | application/pdf | |
| dc.format.extent | 51 páginas | |
| dc.identifier.uri | https://dspace.ucuenca.edu.ec/handle/123456789/46872 | |
| dc.language.iso | spa | |
| dc.publisher | Universidad de Cuenca | |
| dc.relation.ispartof | TE4-ODONRO; 032 | |
| dc.rights | https://creativecommons.org/licenses/by-nc-sa/4.0 | |
| dc.rights.accessRights | openAccess | |
| dc.subject | Odontología | |
| dc.subject | Resistencia a la fractura | |
| dc.subject | Bases de titanio | |
| dc.subject | Resina impresa 3D | |
| dc.subject | Zirconio | |
| dc.subject.other | Odontología::Rehabilitación oral | |
| dc.title | Resistencia a la fractura y el modo de falla de coronas atornilladas incisivas de resina impresa en 3D y zirconio en bases de titanio largas y cortas en implantes de conexión cónica | |
| dc.title.alternative | RESISTENCIA A LA FRACTURA Y EL MODO DE FALLA DE CORONAS ATORNILLADAS INCISIVAS DE RESINA IMPRESA EN 3D Y ZIRCONIO EN BASES DE TITANIO LARGAS Y CORTAS EN IMPLANTES DE CONEXIÓN CÓNICA | |
| dc.type | masterThesis | |
| dcterms.description | Especialista en Rehabilitación Oral y Prótesis Implanto Asistida | |
| dcterms.spatial | Cuenca, Ecuador |
Files
Original bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- Trabajo-de-Titulación.pdf
- Size:
- 774.12 KB
- Format:
- Adobe Portable Document Format
- Description:
- Acceso restringido (versión presentada)
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.71 KB
- Format:
- Item-specific license agreed upon to submission
- Description: