Sistema de monitoreo remoto IoT de frecuencia cardíaca y saturación de oxígeno para pacientes post COVID-19

dc.contributor.advisorMorocho Zurita, Carlos Villie
dc.contributor.authorNeira Carvallo, David Damián
dc.contributor.authorRíos Cedillo, Esteban Javier
dc.date.accessioned2022-09-22T15:42:08Z
dc.date.available2022-09-22T15:42:08Z
dc.date.issued2022-09-22
dc.descriptionEl presente trabajo de titulaci ́on comprende el desarrollo de un dispositivo IoT de monitoreo remoto de frecuencia card ́ıaca (FC) y saturaci ́on de oxigeno (SpO2), o pulsiox ́ımetro, mediante herramientas de software y hardware libre. Este dispositivo cuenta con conexi ́on inal ́ambrica Wi-Fi para la conexi ́on a una base de datos alojada en un servidor en la nube. El servidor se accede mediante una interfaz creada en HTML con PHP. Para la construcci ́on del dispositivo se utiliz ́o el m ́odulo MAX30102, un sistema en chip especializado en la obtenci ́on de la FC y SpO2. El procesamiento de los par ́ametros medidos se realiz ́o mediante el m ́odulo ESP8266, este m ́odulo adicionalmente permite la conexi ́on inal ́ambrica Wi-Fi para el env ́ıo de los datos. As ́ı mismo, el dispositivo cuenta con una pantalla OLED que muestra los valores de FC y SpO2 en el mismo dispositivo y una bater ́ıa de litio que permite que este sea port ́atil. Todo esto se encuentra contenido en un encapsulado que se dise ̃n ́o en una herramienta de dise ̃no 3D para su impresi ́on. El desarrollo del software se realiz ́o usando herramientas libres. La base de datos se desarroll ́o con MySQL mientras que el servidor utilizado fue Apache. Para la comprobaci ́on del funcionamiento del dispositivo, se realiz ́o dos experimen- tos. El primero consisti ́o en pruebas de laboratorio con personas sanas con el cual se compararon los resultados obtenidos con un pulsiox ́ımetro profesional de uso m ́edico. El segundo experimento realizado se hizo en conjunto con estudiantes de fisioterapia como apoyo en la realizaci ́on de un trabajo de titulaci ́on, en el cual se utiliz ́o el dis- positivo para medici ́on de la FC y SpO2 en personas Post COVID-19. De la misma manera, en este experimento se realiz ́o la comparaci ́on de los valores obtenidos con el mismo pulsiox ́ımetro profesional. A partir de los experimentos realizados se realiz ́o un an ́alisis estad ́ıstico sobre la diferencia entre los valores obtenidos con el pulsiox ́ımetro construido y el pulsiox ́ımetro profesional de referencia.en_US
dc.description.abstractThis final degree work involves the development of an IoT device for remote moni- toring of heart rate (HR) and oxygen saturation (SpO2), also called pulse oximeter, by using free software and hardware tools. One of the main characteristics of this device is that it has a Wi-Fi wireless connection through which it connects to a database that is hosted on a cloud server which is accessed through an interface created in HTML with PHP. For the construction of the device, the MAX30102 module was used, which is a system-on-chip specialized in obtaining HR and SpO2. The processing of the measured parameters was carried out through the ESP8266 module, which allows the Wi-Fi wireless connection to send the data. The device also has an OLED screen that shows the values of HR and SpO2 and a lithium battery that allows it to be portable. All of these previously mentioned tools are contained in a package that was designed in 3D for printing. The development of the software was carried out with the use of free tools. The database was developed by MySQL while the server used was Apache. To test the functionality of the device, two experiments were carried out. The first experiment involved the use of healthy people whose results were compared with a professional pulse oximeter for medical use. The second experiment was done in con- junction with physiotherapy students as support in developing a final degree work. In this experiment, the device was used to measure HR and SpO2 in Post-COVID-19 people. Same as before, the values obtained from this experiment were compared to the values obtained with the same professional pulse. Based on the results from the experiments carried out, a statistical analysis was carried out on the difference between the values obtained with the constructed pulse oximeter and the professional pulse oximeter used as reference.en_US
dc.description.cityCuencaen_US
dc.description.degreeIngeniero en Electrónica y Telecomunicacionesen_US
dc.formatapplication/pdfen_US
dc.format.extent129 páginasen_US
dc.identifier.urihttp://dspace.ucuenca.edu.ec/handle/123456789/39927
dc.language.isospaen_US
dc.publisherUniversidad de Cuencaen_US
dc.relation.ispartofseriesTET;127
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.accessRightsopenAccessen_US
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectElectrónicaen_US
dc.subjectFrecuencia cardíacaen_US
dc.subjectCOVID-19en_US
dc.subjectBases de datosen_US
dc.subject.otherSoftwareen_US
dc.titleSistema de monitoreo remoto IoT de frecuencia cardíaca y saturación de oxígeno para pacientes post COVID-19en_US
dc.typebachelorThesisen_US
dc.ucuenca.areaconocimientounescoamplio33 Ciencias Tecnológicasen_US
dc.ucuenca.areaconocimientounescodetallado3307.99 Otrasen_US
dc.ucuenca.areaconocimientounescoespecifico3307 Tecnología Electrónicaen_US
dc.ucuenca.correspondenciadavidneira97@outlook.comen_US
dc.ucuenca.correspondenciaeriosced@gmail.comen_US
dc.ucuenca.id0300930328en_US
dc.ucuenca.idautor0104167804en_US
dc.ucuenca.idautor0106433816en_US
dc.ucuenca.responsablerecepcionPeñafiel Vázquez Erika Sofíaen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Trabajo-de-titulación.pdf
Size:
7.66 MB
Format:
Adobe Portable Document Format
Description:
Versión presentada (texto completo)

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: