Residential solar thermal performance considering self-shading incidence between tubes in evacuated tube and flat plate collectors

dc.contributor.authorZalamea León, Esteban Felipe
dc.contributor.authorBarragán Escandón, Edgar Antonio
dc.contributor.authorCalle Sigüencia, John Ignacio
dc.contributor.authorAstudillo Flores, Mateo Ismael
dc.contributor.authorJuela Quintuña, Diego Marcelo
dc.date.accessioned2022-01-27T13:56:24Z
dc.date.available2022-01-27T13:56:24Z
dc.date.issued2021
dc.description.abstractThe performance of solar thermal technology under high-altitude equatorial climatic and solar path conditions has not been determined. Evacuated tube solar collectors are more efficient than flat plate collectors in cold and cloudy regions; however, due to their dependence on orientation, the irradiation incidence between the tubes of these collectors can be blocked. In this study, the performance of these types of collectors was analyzed to determine the implications of their orientation under these specific climate conditions. Four solar thermal systems were installed: two of the systems used evacuated tube collectors, and two used flat plate collectors. Each collector was connected to storage and discharge points to simulate residential consumption when observing the real performance of the four systems in terms of irradiation availability. The evacuated tube collectors were more efficient and reduced the backup energy requirement by up to 20.6% more on average than the flat plate collectors. In addition, the performance of the evacuated tube collectors increased by up to 9.8% when the tubes were arranged parallel to the solar path, compared to when they were arranged perpendicular to the solar path, verifying that the blockage effect is an important parameter to consider for evacuated tube technology. The main novelty of this research is the comparison of these two technologies under different orientations, with perpendicular and parallel dispositions toward the solar path, in a high-altitude equatorial location where solar collectors are not typically oriented in any particular orientation. To the best of our knowledge, this is the first complete analysis of real systems deployed under these conditions
dc.identifier.doi10.3390/su132413870
dc.identifier.issn2071-1050
dc.identifier.urihttps://www.mdpi.com/2071-1050/13/24/13870
dc.language.isoes_ES
dc.sourceSustainability
dc.subjectSolar thermal collectors
dc.subjectFlat plate collectors
dc.subjectEvacuated tube collectors
dc.subjectAndean equatorial climate
dc.subjectDomestic hot water
dc.titleResidential solar thermal performance considering self-shading incidence between tubes in evacuated tube and flat plate collectors
dc.title.alternativeResidential solar thermal performance considering self-shading incidence between tubes in evacuated tube and flat plate collectors
dc.typeARTÍCULO
dc.ucuenca.afiliacionZalamea, E., Universidad de Cuenca, Cuenca, Ecuador
dc.ucuenca.afiliacionBarragán, E., Universidad Politécnica Salesiana, Cuenca, Ecuador
dc.ucuenca.afiliacionCalle, J., Universidad Politécnica Salesiana, Cuenca, Ecuador
dc.ucuenca.afiliacionAstudillo, M., Universidad de Cuenca, Cuenca, Ecuador
dc.ucuenca.afiliacionJuela, D., Universidad de Cuenca, Cuenca, Ecuador
dc.ucuenca.areaconocimientofrascatiamplio2. Ingeniería y Tecnología
dc.ucuenca.areaconocimientofrascatidetallado2.5.1 Ingeniería de Materiales
dc.ucuenca.areaconocimientofrascatiespecifico2.5 Ingeniería de los Materiales
dc.ucuenca.areaconocimientounescoamplio07 - Ingeniería, Industria y Construcción
dc.ucuenca.areaconocimientounescodetallado0712 - Tecnología de Protección del Medio Ambiente
dc.ucuenca.areaconocimientounescoespecifico071 - Ingeniería y Profesiones Afines
dc.ucuenca.cuartilQ1
dc.ucuenca.factorimpacto3,9
dc.ucuenca.idautor0102125952
dc.ucuenca.idautor0102516457
dc.ucuenca.idautor0102118213
dc.ucuenca.idautor0604849265
dc.ucuenca.idautor0302396718
dc.ucuenca.indicebibliograficoSCOPUS
dc.ucuenca.numerocitaciones0
dc.ucuenca.urifuentehttps://www.mdpi.com/journal/sustainability
dc.ucuenca.versionVersión publicada
dc.ucuenca.volumenVolumen 13, número 24

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
documento.pdf
Size:
449.25 KB
Format:
Adobe Portable Document Format
Description:
document

Collections