Refractive and Topographic Parameters of the Belin/Ambrósio Module in Patients with Refractive Defects in Cuenca, Ecuador

dc.contributor.authorRojas Alvarez, Eduardo
dc.contributor.authorAlvarez Guachichulca, Javier Santiago
dc.contributor.authorChavez Espinoza, David Sebastian
dc.date.accessioned2023-04-10T13:05:35Z
dc.date.available2023-04-10T13:05:35Z
dc.date.issued2023
dc.description.abstractObjective: This study aimed to describe the refractive and topographic parameters of the Belin/Ambrósio module in patients with refractive defects at the Latino clinic in Cuenca, Ecuador, between 2017 to 2021. Methods: A descriptive, cross-sectional study was carried out. A database included anonymous cases of patients with refractive defects treated at the ophthalmological consultation of a Latino clinic from January, 2017 to June, 2021 was searched. Data was collected using a form containing study variables. Microsoft Excel and SPSS were used for data collection and analysis using frequencies, percentages, and measures of central tendency. Results: The sample consisted of 120 patients; 61.7% were women, and 38.3% were men. Moreover, 70.8% of patients were young adults. The pachymetry mean of the center of the pupil, apex, and position of lowest pachymetry was 521 µm, 520 µm, and 513 µm, respectively. The means of the flattest keratometry, curviest keratometry, and maximum keratometry were 43.30 D, 46.32 D, and 48.01 D, respectively. Conclusion: Cases distribution according to anterior and posterior elevation showed pathological values ​​in more than 50% of the studied corneas. According to the average progression index, pathological elevation was found in 18.8% of the cases, and according to the average deviations, 25.4% presented corneal ectasia in different stages.
dc.identifier.doi10.2174/18743641-v17-230223-2022-52
dc.identifier.issn1874-3641
dc.identifier.urihttps://www.scopus.com/record/display.uri?eid=2-s2.0-85150170168&origin=resultslist&sort=plf-f&src=s&st1=1874-3641&sid=9b642a030a9a42fbc15224c690b5468c&sot=b&sdt=b&sl=15&s=ISSN%281874-3641%29&relpos=0&citeCnt=0&searchTerm=
dc.language.isoes_ES
dc.sourceThe Open Ophthalmology Journal
dc.subjectKeratoconus
dc.subjectBelin Ambrósio
dc.subjectCorneal ectasia
dc.subjectRefractive defects
dc.subjectPatients
dc.subjectCorneas
dc.titleRefractive and Topographic Parameters of the Belin/Ambrósio Module in Patients with Refractive Defects in Cuenca, Ecuador
dc.title.alternativeParámetros topográficos y refractivos del Módulo de Belin Ambrosio en pacientes con defectos refractivos
dc.typeARTÍCULO
dc.ucuenca.afiliacionRojas, E., Universidad de Cuenca, Facultad de Ciencias Médicas, Cuenca, Ecuador
dc.ucuenca.afiliacionAlvarez, J., Universidad de Cuenca, Facultad de Ciencias Médicas, Cuenca, Ecuador
dc.ucuenca.afiliacionChavez, D., Universidad de Cuenca, Facultad de Ciencias Médicas, Cuenca, Ecuador
dc.ucuenca.areaconocimientofrascatiamplio3. Ciencias Médicas y de la Salud
dc.ucuenca.areaconocimientofrascatidetallado3.2.24 Oftalmología
dc.ucuenca.areaconocimientofrascatiespecifico3.2 Medicina Clínica
dc.ucuenca.areaconocimientounescoamplio09 - Salud y Bienestar
dc.ucuenca.areaconocimientounescodetallado0912 - Medicina
dc.ucuenca.areaconocimientounescoespecifico091 - Salud
dc.ucuenca.correspondenciaRojas Alvarez, Eduardo , drerojasalvarez@gmail.com
dc.ucuenca.cuartilQ3
dc.ucuenca.factorimpacto0.4
dc.ucuenca.idautor0151403243
dc.ucuenca.idautor0105249445
dc.ucuenca.idautor0104591789
dc.ucuenca.indicebibliograficoSCOPUS
dc.ucuenca.numerocitaciones0
dc.ucuenca.urifuentehttps://openophthalmologyjournal.com/
dc.ucuenca.versionVersión publicada
dc.ucuenca.volumenVolumen 17, número 0

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
documento.pdf
Size:
237.11 KB
Format:
Adobe Portable Document Format
Description:
document

Collections