Publication:
Evaluating reliability of ultrashort heart rate variability parameters in metabolic syndrome subjects

dc.contributor.authorAstudillo Salinas, Darwin Fabián
dc.contributor.authorPalacio Baus, Kenneth Samuel
dc.contributor.authorSolano Quinde, Lizandro Damián
dc.contributor.authorWong De Balzan, Sara
dc.date.accessioned2018-01-11T16:47:03Z
dc.date.available2018-01-11T16:47:03Z
dc.date.issued2016-08-30
dc.description.abstractHeart rate variability (HRV) analysis is barely employed in healthcare environments mainly because of the lack of standard values determining the sympathovagal balance and the difficulty to register RR stationary series. Recent studies have proposed the use of shorter HRV series. For this work, we use a public metabolic syndrome subjects database retrieved during oral glucose tolerance test. In order to explore ultra-short HRV measures reliability we employ an autoregressive model using Burg method, such that short RR sequences can be evaluated while maintaining a good frequency resolution. RR, SD, rMSSD, LF, HF, LFn and LF/HF were computed for different RR sequences (10 min, 5 min, 1 min, 30 s, 10 s). To evaluate the reliability we used the intraclass correlation coefficient (ICC). Additionally, we compared the sympathovagal balance parameters (LFn, LF/HF) among the stages (basal and 30 min). Considering 10 min long registers as references, parameters obtained from 5 min long series present ICC values above 0.78 for all cases. One min long registers present ICC values above 0.70 only for temporal parameters in both RR series and rMSSD. By comparing LFn and LF/HF parameters among the basal state and 30 min, we observed a significant increase of the sympathetic tone (p < 0.05). However, these differences are important only for 10 and 5 min series. In general, we observe that temporal parameters exhibit higher reliability than those the spectral ones. Nonetheless, registers duration below one min do not present adequate results for the spectral parameters in this work.
dc.description.cityBucaramanga
dc.identifier.doi10.1109/STSIVA.2016.7743361
dc.identifier.isbn9781509037971
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85002669240&doi=10.1109%2fSTSIVA.2016.7743361&partnerID=40&md5=6d87785fafd0d63a1ac6aea5f0e9970d
dc.identifier.urihttp://dspace.ucuenca.edu.ec/handle/123456789/28985
dc.language.isoen_US
dc.publisherINSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS INC.
dc.source2016 21st Symposium on Signal Processing, Images and Artificial Vision, STSIVA 2016
dc.titleEvaluating reliability of ultrashort heart rate variability parameters in metabolic syndrome subjects
dc.typeArticle
dc.ucuenca.afiliacionastudilllo, d., deet, university of cuenca cuenca, ecuador
dc.ucuenca.afiliacionpalacio-baus, k., deet, university of cuenca cuenca, ecuador
dc.ucuenca.afiliacionsolano-quinde, l., deet, university of cuenca cuenca, ecuador
dc.ucuenca.afiliacionwong, s., deet, university of cuenca cuenca, ecuador
dc.ucuenca.embargoend2022-01-01 0:00
dc.ucuenca.idautor0103907036
dc.ucuenca.idautor0103566360
dc.ucuenca.idautor0102428893
dc.ucuenca.idautor081929618
dc.ucuenca.indicebibliograficoSCOPUS
dc.ucuenca.nombrerevista21st Symposium on Signal Processing Images and Artificial Vision STSIVA 2016
dspace.entity.typePublication
dspace.entity.typePublication
relation.isAuthorOfPublication0ace217e-689c-4f2a-bbbf-0b5171b24110
relation.isAuthorOfPublication2541297e-ad0c-4d25-8354-4d5bce749f5c
relation.isAuthorOfPublicationdb82deb3-5465-4f62-b097-bf4beba1623a
relation.isAuthorOfPublication.latestForDiscovery0ace217e-689c-4f2a-bbbf-0b5171b24110

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
documento.pdf
Size:
168.92 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
19.94 KB
Format:
Plain Text
Description:

Collections