Logo Repositorio Institucional

Por favor, use este identificador para citar o enlazar este ítem: http://dspace.ucuenca.edu.ec/handle/123456789/38272
Título : Hydrodynamic evaluation of five influent distribution systems in a cylindrical UASB reactor using CFD simulations
Autor: Cobos Cobos, Fabiola Estefania
Alvarado Martinez, Andres Omar
Nopens, Ingmar
Cisneros Ramos, Juan Fernando
Rehman, Usman
Pelaez Samaniego, Manuel Raul
Correspondencia: Cisneros Ramos, Juan Fernando, juan.cisneros@ucuenca.edu.ec
Palabras clave : Wastewater treatment
Computational fluid dynamics
Granulation
Influent distribution system
Opposite radial inflow
UASB
Área de conocimiento FRASCATI amplio: 2. Ingeniería y Tecnología
Área de conocimiento FRASCATI detallado: 2.11.2 Otras Ingenierias y Tecnologías
Área de conocimiento FRASCATI específico: 2.11 Otras Ingenierias y Tecnologías
Área de conocimiento UNESCO amplio: 07 - Ingeniería, Industria y Construcción
ÁArea de conocimiento UNESCO detallado: 0712 - Tecnología de Protección del Medio Ambiente
Área de conocimiento UNESCO específico: 071 - Ingeniería y Profesiones Afines
Fecha de publicación : 2021
Volumen: Volumen 13, número 21
Fuente: Water
metadata.dc.identifier.doi: 10.3390/w13213141
Tipo: ARTÍCULO
Abstract: 
UASB reactors are a promising option for environmentally friendly wastewater treatment due to their reduced carbon footprint and their capacity to treat a variety of wastewater strengths, among other recognized advantages over alternative wastewater treatment systems. The Influent Distribution System (IDS) is a critical structure for generating granules in a UASB reactor since it provides the required flow hydrodynamics for their formation. Thus, the objective of this study was to evaluate and compare the efficiency of five IDS configurations to generate ideal granulation conditions using Computational Fluid Dynamics (CFD) simulations. The IDS configurations were as follows: (C1) single radial inflow, (C2) upward axial inflow, (C3) downward distributed axial inflow, and two novel configurations in the form of (C4) double opposite radial inflow and (C5) downward tangential inflow. The hydrodynamic response of configuration C1 was validated in a physical model with dynamic Froude similitude. The granulation measurement was velocity-based in the reactor reaction zone using steady-state CFD simulations. The novel IDS configuration C4 was the one that resulted in the highest granulation volume, with up to 45.5% of the potential granulation volume of the UASB reactor, in contrast to the IDS C2 that obtained the lowest granulation with only 10.8%. Results confirm that the IDS directly impacts the hydrodynamics of the reactor and that model-based design can be used to ascertain IDS configurations that better promote granulation in UASB reactors
URI : http://dspace.ucuenca.edu.ec/handle/123456789/38272
https://www.scopus.com/record/display.uri?eid=2-s2.0-85118826614&doi=10.3390%2fw13213141&origin=inward&txGid=540d62af369bd744e535da1408fd9465&featureToggles=FEATURE_NEW_DOC_DETAILS_EXPORT:1
URI Fuente: https://www.mdpi.com/2073-4441/13/21
ISSN : 2073-4441
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
documento.pdfdocument10.69 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está protegido por copyright original



Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00