Title: Hydrodynamic evaluation of five influent distribution systems in a cylindrical UASB reactor using CFD simulations
Authors: Cobos Cobos, Fabiola Estefania
Alvarado Martinez, Andres Omar
Nopens, Ingmar
Cisneros Ramos, Juan Fernando
Rehman, Usman
Pelaez Samaniego, Manuel Raul
metadata.dc.ucuenca.correspondencia: Cisneros Ramos, Juan Fernando, juan.cisneros@ucuenca.edu.ec
Keywords: Wastewater treatment
Computational fluid dynamics
Granulation
Influent distribution system
Opposite radial inflow
UASB
metadata.dc.ucuenca.areaconocimientofrascatiamplio: 2. Ingeniería y Tecnología
metadata.dc.ucuenca.areaconocimientofrascatidetallado: 2.11.2 Otras Ingenierias y Tecnologías
metadata.dc.ucuenca.areaconocimientofrascatiespecifico: 2.11 Otras Ingenierias y Tecnologías
metadata.dc.ucuenca.areaconocimientounescoamplio: 07 - Ingeniería, Industria y Construcción
metadata.dc.ucuenca.areaconocimientounescodetallado: 0712 - Tecnología de Protección del Medio Ambiente
metadata.dc.ucuenca.areaconocimientounescoespecifico: 071 - Ingeniería y Profesiones Afines
Issue Date: 2021
metadata.dc.ucuenca.volumen: Volumen 13, número 21
metadata.dc.source: Water
metadata.dc.identifier.doi: 10.3390/w13213141
metadata.dc.type: ARTÍCULO
Abstract: 
UASB reactors are a promising option for environmentally friendly wastewater treatment due to their reduced carbon footprint and their capacity to treat a variety of wastewater strengths, among other recognized advantages over alternative wastewater treatment systems. The Influent Distribution System (IDS) is a critical structure for generating granules in a UASB reactor since it provides the required flow hydrodynamics for their formation. Thus, the objective of this study was to evaluate and compare the efficiency of five IDS configurations to generate ideal granulation conditions using Computational Fluid Dynamics (CFD) simulations. The IDS configurations were as follows: (C1) single radial inflow, (C2) upward axial inflow, (C3) downward distributed axial inflow, and two novel configurations in the form of (C4) double opposite radial inflow and (C5) downward tangential inflow. The hydrodynamic response of configuration C1 was validated in a physical model with dynamic Froude similitude. The granulation measurement was velocity-based in the reactor reaction zone using steady-state CFD simulations. The novel IDS configuration C4 was the one that resulted in the highest granulation volume, with up to 45.5% of the potential granulation volume of the UASB reactor, in contrast to the IDS C2 that obtained the lowest granulation with only 10.8%. Results confirm that the IDS directly impacts the hydrodynamics of the reactor and that model-based design can be used to ascertain IDS configurations that better promote granulation in UASB reactors
URI: http://dspace.ucuenca.edu.ec/handle/123456789/38272
https://www.scopus.com/record/display.uri?eid=2-s2.0-85118826614&doi=10.3390%2fw13213141&origin=inward&txGid=540d62af369bd744e535da1408fd9465&featureToggles=FEATURE_NEW_DOC_DETAILS_EXPORT:1
metadata.dc.ucuenca.urifuente: https://www.mdpi.com/2073-4441/13/21
ISSN: 2073-4441
Appears in Collections:Artículos

Files in This Item:
File Description SizeFormat 
documento.pdfdocument10.69 MBAdobe PDFThumbnail
View/Open


This item is protected by original copyright



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00