dc.contributor.advisorGonzález Morales, Luis Gerardo-
dc.contributor.authorGuerra Chávez, Joseph David-
dc.date.accessioned2019-12-17T18:01:26Z-
dc.date.available2019-12-17T18:01:26Z-
dc.date.issued2019-12-17-
dc.identifier.urihttp://dspace.ucuenca.edu.ec/handle/123456789/33747-
dc.descriptionSe evalúo la calidad de energía eléctrica del laboratorio de automatización de la Facultad de Informática y Electrónica de la ESPOCH, ubicado en la ciudad de Riobamba. El análisis considera la variación de la frecuencia, amplitud, forma de onda y simetría según las normativas de la ARCONEL 005/18 y 004/18, EN50160, IEC 61000-4-15 y IEEE 519-2014. El estudio se justifica debido a continuos incidentes en el equipamiento de alto costo disponible en el laboratorio. Del análisis realizado en el tablero principal, con el equipo Fluke 435 aplicando una tasa de muestreo de 10min durante 7 días según normativa del ARCONEL. Se destaco el flicker de Plt, en las fases C con 7,24% y en B con 6,05%. Se obtuvo un promedio de la distorsión armónica de corriente total en las fases A, B, C y neutro de 44,61%, 65,24%, 55,27% y 231,94% respectivamente. Los armónicos de orden 3, 5, 7, 9 y 11 con mayor distorsión de corriente individual se presentan en la fase B con 46,22%, 34,52%, 22,15%, 15,26% y 9,14%, respectivamente. El factor de potencia total calculado fue 0,83p.u. y el mínimo 0,79p.u. en la fase B, valores que incumplen la normativa. Como solución se propone instalar un filtro activo en paralelo de 30A, del tipo AFQm-4WF-030M-400 de CIRCUTOR o el SINAFM440030W de LIFASA, verificar las conexiones eléctricas y evitar posibles modificaciones o expansiones de las mismas sin un estudio previo. Esto garantizará la calidad de energía eléctrica del edificio y el buen funcionamiento de los equipos existente.es_ES
dc.description.abstractThe electrical power quality of the automation laboratory of the Faculty of Informatics and Electronics of ESPOCH, located in the city of Riobamba, was evaluated. The analysis considers the variation of frequency, amplitude, waveform and symmetry according to the standards of ARCONEL 005/18 and 004/18, EN50160, IEC 61000-4-15 and IEEE 519-2014. The study is justified due to continuous incidents in the high-cost equipment available in the laboratory. From the analysis carried out on the main board, with the Fluke 435 equipment applying a sampling rate of 10min during 7 days according to ARCONEL regulations. The flicker of Plt was highlighted, in phases C with 7.24% and in B with 6.05%. The average harmonic distortion of total current in phases A, B, C and neutral was 44.61%, 65.24%, 55.27% and 231.94% respectively. The harmonics of order 3, 5, 7, 9 and 11 with the highest individual current distortion are presented in phase B with 46.22%, 34.52%, 22.15%, 15.26% and 9.14%, respectively. The total power factor calculated was 0.83p.u. and the minimum 0.79p.u. in phase B, values that do not comply with regulations. As a solution it is proposed to install an active filter in parallel of 30A, of the type AFQm-4WF-030M-400 of CIRCUTOR or the SINAFM440030W of LIFASA, to verify the electrical connections and to avoid possible modifications or expansions of the same ones without a previous study. This will guarantee the electrical power quality of the building and the proper functioning of the existing equipment.es_ES
dc.formatapplication/pdfes_ES
dc.language.isospaes_ES
dc.publisherUniversidad de Cuencaes_ES
dc.relation.ispartofseriesTE;467-
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectIngeniería Eléctricaes_ES
dc.subjectEnergía eléctricaes_ES
dc.subjectCalidad energéticaes_ES
dc.subjectPotencia energéticaes_ES
dc.titleEvaluación de la calidad de energía eléctrica del laboratorio de automatización de la facultad de Informática y Electrónica - ESPOCHes_ES
dc.typebachelorThesises_ES
dc.ucuenca.paginacion139 páginases_ES
dc.description.degreeIngeniero Eléctricoes_ES
dc.description.cityCuenca, Ecuadores_ES
dc.ucuenca.id1729711059es_ES
dc.ucuenca.idautor0604239152es_ES
dc.ucuenca.versionsubmittedVersiones_ES
dc.ucuenca.correspondenciajoseph.guerra@ucuenca.edu.eces_ES
Appears in Collections:Tesis de Pregrado

Files in This Item:
File Description SizeFormat 
Trabajo-de-Titulación.pdfVersión presentada (texto completo)10.43 MBAdobe PDFView/Open


This item is protected by original copyright



This item is licensed under a Creative Commons License Creative Commons

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00