dc.contributor.advisorMogrovejo Carrasco, Daniel Estuardo-
dc.contributor.authorAsmal Peña, Gustavo Andrés-
dc.contributor.authorGonzález Guamán, Pablo Fernando-
dc.date.accessioned2019-10-15T22:29:52Z-
dc.date.available2019-10-15T22:29:52Z-
dc.date.issued2019-10-15-
dc.identifier.urihttp://dspace.ucuenca.edu.ec/handle/123456789/33504-
dc.descriptionEl hormigón a edades tempranas se encuentra expuesto a factores ambientales que provocan la pérdida de humedad y temperatura necesaria para adquirir las propiedades físicas y mecánicas deseadas, lo cual afecta directamente a su resistencia. El objetivo principal del proyecto fue analizar la influencia en la resistencia final del hormigón en tres tipos de elementos: cilindros, vigas y losas, expuestos a diferentes condiciones de curado. Se definió una dosificación patrón de aproximadamente 240 kg/cm2 y se elaboraron 12 muestras de cada elemento de hormigón. El primer proceso de curado se realizó en una piscina de laboratorio siguiendo las especificaciones de la normativa (sumersión); en los otros dos procesos se expuso los elementos a condiciones extremas de viento y temperatura, respectivamente; y finalmente se aplicó el uso de un curador (antisol) como se lo realiza en obra. Se utilizaron ensayos destructivos y no destructivos en los diferentes elementos de hormigón. Los ensayos no destructivos aplicados fueron el ultrasonido y la resistividad eléctrica, los cuales indican parámetros de calidad del hormigón. En los ensayos destructivos se realizaron pruebas de resistencia a la compresión en cilindros, y resistencia a la tracción en vigas y losas. Los especímenes de hormigón fueron ensayados a los 7, 14 y 28 días de curado. Las mayores resistencias a los 28 días de curado en los cilindros se presentaron en los elementos curados en laboratorio, alcanzando resistencias de 257 kg/cm2; en los elementos que se aplicó el uso del curador existió una reducción del 10% en comparación del curado por sumersión. La afección más notoria con respecto a la resistencia final se dio tanto en condiciones de exposición al viento, como en exposiciones a bajas temperaturas-viento, presentándose una reducción del 27% y 31%, respectivamente, esto se debe a la pérdida de humedad que provoca las diferentes condiciones ambientales a la que son expuestas los elementos. En las vigas y losas al igual que en los cilindros la condición más desfavorable se presentó cuando se expuso los elementos a zonas de baja temperatura-viento, la reducción en la resistencia a los 28 días fue de 31% en relación con las curadas en laboratorio. Con los resultados obtenidos se corroboró la relación directa que existe entre la resistencia final del hormigón y el curado del mismo, por lo que es muy importante tomar en cuenta las condiciones ambientales presentadas en el medio para poder realizar un correcto proceso de curado y alcanzar las propiedades deseadas y cumplir con los parámetros de diseño especificados.es_ES
dc.description.abstractConcrete at an early age is exposed to environmental factors that cause the loss of humidity and temperature necessary to acquire the desired physical and mechanical properties, affecting its resistance. The main objective of the project was to analyze the influence on the final resistence of concrete in three types of elements: cylinders, beams and slabs, exposed to different curing conditions. A standard dosage of approximately 240 kg / cm2 was defined and 12 samples of each concrete element were made. The first curing process was carried out in a laboratory pool following the specifications of the regulations (submersion). In the other two processes, the elements were exposed to extreme wind and temperature conditions, respectively. Lastly, the use of a curator (antisol) was applied and done on site. Destructive and non-destructive tests were used on the different elements of concrete. The non-destructive tests applied were ultrasound and electrical resistivity, which indicated concrete quality parameters. In the destructive test, tests of compressive strength in cylinders, tensile strength in beams, and slabs were performed. Concrete specimens were tested at 7, 14 and 28 days of curing. The greatest resistance at 28 days of curing in the cylinders was presented in the elements cured in the laboratory, reaching resistance of 257 kg / cm2. In the elements where the use of the curator was applied, there was a 10% reduction compared to submersion curing. The most noticeable condition, with respect to the final resistance, occurred both in conditions of exposure to wind and in exposures at low temperatures-wind, presenting a reduction of 27% and 31%, respectively. This reduction is due to the loss of moisture that causes different environmental conditions to which the elements are exposed. In the beams and slabs, as well as in the cylinders, the most unfavorable condition was presented when the elements were exposed to low temperature-wind areas. The 28-day resistance reduction was 31% in relation to those cured in the laboratory. With the results obtained, the direct relationship between the final strength of the concrete and the curing of the concrete was corroborated. It is very important to take into account the environmental conditions presented in order to carry out a correct curing process, achieve the desired properties, and meet the specified design parameters.es_ES
dc.formatapplication/pdfes_ES
dc.format.extent83 páginasen_US
dc.language.isospaes_ES
dc.relation.ispartofseriesTI;1183-
dc.subjectIngeniería Civiles_ES
dc.subjectHormigónes_ES
dc.subjectResistencia de materialeses_ES
dc.subjectCuradoes_ES
dc.subjectFactores medioambientaleses_ES
dc.titleInfluencia en la resistencia final de elementos de hormigón de geometría variable sometidos a diferentes condiciones de curadoes_ES
dc.typebachelorThesises_ES
dc.description.degreeIngeniero Civiles_ES
dc.description.cityCuenca, Ecuadores_ES
Appears in Collections:Tesis de Pregrado

Files in This Item:
File Description SizeFormat 
Trabajo-de-Titulación.pdfVersión presentada (texto completo)3.21 MBAdobe PDFView/Open


This item is protected by original copyright



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00