Logo Repositorio Institucional

Please use this identifier to cite or link to this item: http://dspace.ucuenca.edu.ec/handle/123456789/27365
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorJiménez Pacheco, Juan Carlos-
dc.contributor.authorRomero Nivelo, Bruno Andrés-
dc.contributor.authorZhindón Sarmiento, Paúl Esteban-
dc.date.accessioned2017-05-10T17:47:58Z-
dc.date.available2017-05-10T17:47:58Z-
dc.date.issued2017-
dc.identifier.urihttp://dspace.ucuenca.edu.ec/handle/123456789/27365-
dc.descriptionUna premisa común de la evaluación sísmica de edificios es la ocurrencia de un modo de falla global gobernado por mecanismos de falla en el plano de las paredes. En el caso de las edificaciones tradicionales de adobe o de ladrillo sin confinar, esta afirmación no es realista: los estudios de daño post-sismo revelan que en estas edificaciones el modo de falla global está regido más bien por mecanismos de falla fuera del plano de las paredes. Esto se debe, fundamentalmente, al bajo grado de ligazón entre paredes y entre paredes y piso. Por ello, el presente trabajo se ocupa de las fallas fuera plano en las paredes, asumiendo como objeto de estudio casas típicas del sector urbano y rural de Cuenca. En primera instancia, a partir de un estudio tipológico de las casas de adobe de Cuenca, se estableció un conjunto de paredes de estudio. Por otra parte, de la revisión del catálogo de fallas propuesto por D’Ayala y Speranza (2003), se determinaron los modos de falla más probables en función de las características geométricas de las paredes. En cuanto a la evaluación sísmica de las paredes, obedeció a una metodología análoga al Método del Espectro de Capacidad (falla global en el plano), consistente en la obtención de un punto de desempeño a partir del cruce entre la curva de capacidad (representada por un período secante efectivo) y la curva de demanda (espectro de diseño). La obtención de la curva de capacidad se basó en un modelo tri-lineal (Doherty et al., 2002), el cual considera las condiciones de borde, el grado de ligazón y la geometría de las paredes, los cuales son englobados en un factor multiplicador de colapso para representar las fallas fuera del plano. La demanda sísmica se definió atendiendo a las recomendaciones de la NEC-15 (2015a) para distintos niveles de aceleración y verificando una reducción por sobre-amortiguamiento debido a la incursión en el rango inelástico. Los resultados finales se presentaron en términos de diagramas de flujo, concebidos para determinar el mecanismo de falla dominante en función de diferentes parámetros geométricos y condiciones de borde de las paredes. Este trabajo se inscribe en el marco de un estudio de vulnerabilidad sísmica del patrimonio edificado de Cuenca que lleva adelante la Red Sísmica del Austro (RSA).es_ES
dc.description.abstractA common premise of the buildings seismic assessment is the occurrence of a global failure mode governed by in-plane failure mechanisms of walls. In the case of the traditional unconfined buildings of adobe or brick, this statement is not realistic, studies of post-seismic damage observation reveal that in these buildings the common failure mode is governed rather by out-of-plane failures mechanisms in walls. Due mainly to low connection degree between walls and between walls and floor. Thus, this work carries out of the out-of-plane failures in walls, assuming as object of study typical dwellings of the urban and rural sector in Cuenca. In the first instance, from a typological studies of adobe dwellings in Cuenca, a set of walls was stablished as study. In the second instance, based on the failure catalog revision proposed by D’Ayala y Speranza (2003), defines the most probable failure modes in function of geometric characteristics of walls. In terms to the seismic assessment of walls followed an analogous methodology (Cattari et al., 2015) to the Capacity Spectrum Method (Global in-plane failure), which consists on obtaining the performance point since the crossing between the capacity curve (represented by an effective secant period) and the demand curve (design spectrum). The obtained capacity curve is based on a tri-linear model (Doherty et al., 2002) which considered boundary conditions, connection degree, geometric parameters and collapse multipliers to represent out-of-plane failures. The seismic demand is obtained according to recommendations of the NEC-15 (2015a) for different levels of acceleration and verifying a reduction by overdamping due to incursion in the inelastic range. The final results, were presented through flow diagrams based on determinate the dominant failure mechanism in function of different geometric parameters and boundary condition of walls. This project took place within the framework of seismic vulnerability study of built heritage in Cuenca, which is conducted by “Red Sismica del Austro” (RSA).es_ES
dc.formatapplication/pdfes_ES
dc.language.isospaes_ES
dc.relation.ispartofseriesTI;1081-
dc.subjectIngenieria Civiles_ES
dc.subjectCasas De Adobees_ES
dc.subjectTipologias Constructivases_ES
dc.subjectFallases_ES
dc.subjectCurva De Capacidades_ES
dc.subjectEvaluacion Sismicaes_ES
dc.subjectFallo Fuera De Planoes_ES
dc.subjectParedeses_ES
dc.titleEvaluación sísmica de casas de mampostería de tierra vulnerables a modos de falla fuera del planoes_ES
dc.typebachelorThesises_ES
dc.ucuenca.paginacion137 páginases_ES
dc.description.degreeIngeniero Civiles_ES
dc.description.cityCuencaes_ES
dc.ucuenca.id0102260965es_ES
dc.ucuenca.idautor0106630023es_ES
dc.ucuenca.idautor1718164039es_ES
Appears in Collections:Tesis de Pregrado

Files in This Item:
File Description SizeFormat 
Trabajo de Titulación.pdftexto completo5.43 MBAdobe PDFThumbnail
View/Open


This item is protected by original copyright



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00