dc.descriptionIntroducción: El propósito de este estudio fue determinar in vitro la microfiltración apical de obturaciones endodónticas empleando dos cementos selladores, uno a base de hidróxido de calcio (Sealapex) y otro a base de agredo de trióxido mineral (Fillapex) en 60 premolares inferiores unirradiculares extraídos. Métodos: Cada pieza dental fue sometida a un proceso de limpieza de tejidos orgánicos, los dientes fueron estandarizados a una longitud de 16mm a partir del ápice mediante discos diamantados, se realizó la preparación biomecánica utilizando la técnica de retroceso, se separó al azar las muestras en tres grupos, dos de 30 piezas cada uno y un grupo de 5 piezas para el control de penetración de tinta. Para la obturación de las 60 piezas se utilizó la técnica de condensación lateral, empleando Sealapex en las primeras 30 y Fillapex en las otras 30. Las piezas fueron sumergidas en frascos individuales con tinta china durante 7 días y fueron sometidas a un proceso de diafanización. Cada pieza se evaluó con microscopia digital (Microcapture) con un objetivo de 20x registrando la longitud de filtración apical en milímetros. Resultados: No hubo diferencia estadísticamente significativa en cuanto a la microfiltración apical entre el agregado de trióxido mineral (Fillapex) e hidróxido de calcio (Sealapex)es_ES
dc.description.abstractIntroduction: The purpose of this study was to determine in vitro the apical leakage endodontic sealers using two cement sealers, one based on calcium hydroxide (Sealapex) and another based MTA (Fillapex) in 60 extracted single-rooted mandibular premolars. Methods: Each tooth was subjected to a cursory cleaning process organic tissue, the teeth were standardized to a length of 16mm from tip by diamond disks, biomechanics preparation was performed using the technique step back, separated random samples into three groups, two of 30 pieces each and a group of 5 pieces for controlling ink penetration. The lateral condensation technique using Sealapex in the first 30 and MTA Fillapex in the other 30 are used for sealing of 60 pieces. The pieces were submerged in individual dispensers with ink for 7 days and were subjected to a process of diaphanisation. Each piece was evaluated by digital microscopy (MicroCapture) with a 20x objective recording length in millimeters apical leakage. Results: There was no statistically significant difference in the apical leakage between the MTA (Fillapex) and calcium hydroxide (Sealapex)es_ES
dc.description.cityCuencaes_ES
dc.description.degreeOontólogoes_ES
dc.formatapplication/pdfes_ES
dc.identifier.urihttp://dspace.ucuenca.edu.ec/handle/123456789/24057
dc.language.isospaes_ES
dc.relation.ispartofseriesODON;571
dc.subjectMicrofiltraciones_ES
dc.subjectDiafanizaciones_ES
dc.subjectCemento Sellador A Base De Agregado De Trioxido Minerales_ES
dc.subjectCemento Sellador A Base De Hidroxido De Calcioes_ES
dc.subjectPremolares Inferioreses_ES
dc.titleEvaluación in vitro de la microfiltración apical empleando dos cementos selladores a base de hidróxido de calcio (sealapex) y mta (fillapex) en premolares inferiores unirradiculares extraídoses_ES
dc.typebachelorThesises_ES
dc.ucuenca.id0102851185es_ES
dc.ucuenca.idautor0106289762es_ES
dc.ucuenca.paginacion49 páginases_ES

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Tesis.pdf
Size:
1.02 MB
Format:
Adobe Portable Document Format
Description:
texto completo

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
19.88 KB
Format:
Item-specific license agreed upon to submission
Description: