Prevalencia y factores de riesgo asociados a hipotensión arterial inducida por anestesia raquídea en la cesárea en los hospitales Vicente Corral Moscoso y José Carrasco Arteaga. Cuenca 2021

dc.audience.educationLevelTesis de Especialista en Anestesiologíaen_US
dc.contributor.advisorPacheco Baculima, Juan Pablo
dc.contributor.authorSiguencia Siguencia, Angélica Gabriela
dc.date.accessioned2023-05-03T22:06:59Z
dc.date.available2023-05-03T22:06:59Z
dc.date.issued2023-05-03
dc.descriptionAntecedentes: La anestesia espinal es la técnica neuroaxial más usada en la cesárea, su efecto adverso frecuente es la hipotensión. Existen factores de riesgo asociados a hipotensión materna como: la no rotura del saco amniótico, bloqueo sensitivo alto, peso alto del producto, el sobrepeso y obesidad, entre otros; que al identificarlos se podría prevenir o tratar oportunamente. Objetivo General: Determinar la prevalencia y factores de riesgo asociados a hipotensión arterial inducida por anestesia raquídea en la cesárea en los Hospitales Vicente Corral Moscoso y José Carrasco Arteaga. Materiales y métodos: Se realizó un estudio trasversal en 338 pacientes embarazadas, a término sometidas a cesárea bajo anestesia raquídea. Las variables estudiadas fueron: hipotensión arterial, edad, estado nutricional, antecedente de hipertensión o hipotensión, frecuencia cardiaca basal, ruptura del saco amniótico, gestación múltiple, peso del recién nacido, nivel sensitivo. Los datos fueron registrados en el formulario y procesados en SPSS versión 15. Se obtuvo la razón de prevalencia con un IC del 95%, x2 con el valor de p. Resultados: La prevalencia de hipotensión arterial inducida por anestesia raquídea en la cesárea fue de 60,40%. La hipotensión arterial tuvo una asociación estadísticamente significativa con la edad >35 años (RP de 1,78 con un IC 95%:1,03-3,12), la no rotura del saco amniótico (RP de 2,48 con un IC 95%:1,09-5,66) y el nivel sensitivo entre T1-T4 (RP de 2.77 con un IC 95% de 1,05-5,84). Conclusiones: la prevalencia de hipotensión materna inducida por anestesia raquídea es alta, similar a la obtenido en otros estudios internacionales.en_US
dc.description.abstractBackground: Spinal anesthesia is the most used neuraxial technique in cesarean section, its frequent adverse effect is hypotension. There are risk factors associated with maternal hypotension such as: non-rupture of the amniotic sac, high sensory blockade, high product weight, overweight and obesity, among others; that by identifying them could be prevented or treated in a timely manner. General Objective: To determine the prevalence and risk factors associated with arterial hypotension induced by spinal anesthesia in cesarean section at the Vicente Corral Moscoso and José Carrasco Arteaga Hospitals. Materials and methods: A cross-sectional study was carried out in 338 pregnant patients at term who underwent cesarean section under spinal anesthesia. The variables studied were: arterial hypotension, age, nutritional status, history of hypertension or hypotension, basal heart rate, amniotic sac rupture, multiple gestation, newborn weight, sensory level. Data were recorded in the form and processed in SPSS version 15. The prevalence ratio was obtained with a 95% CI, x2 with the p value. Results: The prevalence of arterial hypotension induced by spinal anesthesia in cesarean section was 60.40%. Arterial hypotension had a statistically significant association with age >35 years (PR of 1.78 with a CI 95%: 1.03-3.12), non-rupture of the amniotic sac (PR of 2.48 with a CI 95%: 1.09-5.66) and the sensitive level between T1-T4 (PR of 2.77 with a 95% CI of 1.05-5.84). Conclusions: the prevalence of maternal hypotension induced by spinal anesthesia is high, similar to that obtained in other international studies.en_US
dc.description.cityCuencaen_US
dc.description.degreeEspecialista en Anestesiologíaen_US
dc.description.uri0000-0001-7779-0184en_US
dc.formatapplication/pdfen_US
dc.format.extent44 páginasen_US
dc.identifier.urihttp://dspace.ucuenca.edu.ec/handle/123456789/41811
dc.language.isospaen_US
dc.publisherUniversidad de Cuencaen_US
dc.relation.ispartofseriesMEDA;113
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.accessRightsopenAccessen_US
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectMedicinaen_US
dc.subjectAnestesia raquídeaen_US
dc.subjectCesáreaen_US
dc.subjectHipotensiónen_US
dc.subject.otherAnestesiologíaen_US
dc.titlePrevalencia y factores de riesgo asociados a hipotensión arterial inducida por anestesia raquídea en la cesárea en los hospitales Vicente Corral Moscoso y José Carrasco Arteaga. Cuenca 2021en_US
dc.typemasterThesisen_US
dc.ucuenca.areaconocimientounescoamplio32 Ciencias Médicasen_US
dc.ucuenca.areaconocimientounescodetallado2411.02 Anestesiologíaen_US
dc.ucuenca.areaconocimientounescoespecifico3213 Cirugíaen_US
dc.ucuenca.responsablerecepcionCarrión Román Daniel Ramiroen_US
dc.ucuenca.titulouniformePREVALENCIA Y FACTORES DE RIESGO ASOCIADOS A HIPOTENSION ARTERIAL INDUCIDA POR ANESTESIA RAQUIDEA EN LA CESAREA EN LOS HOSPITALES VICENTE CORRAL MOSCOSO Y JOSE CARRASCO ARTEAGA. CUENCA 2021en_US
dc.ucuenca.versionsubmittedVersionen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Trabajo-de-Titulación.pdf
Size:
938.76 KB
Format:
Adobe Portable Document Format
Description:
Versión presentada (texto completo)

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: