Prevalencia y factores asociados al abandono del implante subdérmico de Etonogestrel, Distrito 03D01, Azogues, 2014-2017

dc.contributor.advisorHerrera Calvo, Roberto Javier
dc.contributor.assessorVintimilla Maldonado, Jaime Rosendo
dc.contributor.authorCordero Calle, María Cristina
dc.date.accessioned2019-02-05T22:14:03Z
dc.date.available2019-02-05T22:14:03Z
dc.date.issued2019
dc.descriptionAntecedentes. El abandono precoz del implante subdérmico de Etonogestrel constituye un problema de salud pública. Objetivo. Determinar la prevalencia y factores asociados al abandono del implante subdérmico de Etonogestrel en pacientes atendidas en el Distrito de salud 03D01 de Azogues, durante el 2014-2017. Metodología. La muestra incluyó 234 pacientes, constituyendo la población de estudio, seleccionada al azar, dentro del diseño descriptivo. La muestra se calculó con el 95 % de confianza, 4 % de error de inferencia. Los datos se obtuvieron y se analizaron con el Software SPSS, versión 2015. La asociación significativa fue considerada con valor de p < 0,005 Resultados. La edad fluctuó entre 13 y 46 años, el 58,5 % eran casadas, el 49,1 % residían en el área urbana. La prevalencia de retiro precoz del implante fue del 33,3 % (IC 95 % 26,98 - 39,02), y estuvo asociado a alteraciones del sangrado menstrual que altera la calidad de vida (RP 3,9; IC 95 % 3,1 - 5,0; p < 0,001), incremento de peso > 10 Kg (RP 3,5; IC 95 % 2,8 - 4,0; p < 0,001), cefalea intensa ( RP 3,7; IC 95 % 3,0 - 5,0; p < 0,001), dolor en el sitio de inserción (RP 3,1; IC 95 % 2,6 - 4.0; p 0,004) y planificación de embarazo (RP 3,3; IC 95 % 2,7 - 4,0; p < 0,001). Conclusión. La prevalencia de abandono precoz del implante subdérmico de Etonogestrel y factores asociados son similares a lo reportado en la bibliografía.es_ES
dc.description.abstractBackground. The early abandonment of the subdermal Etonogestrel implant constitutes a public health problem Objective. To determine the prevalence and factors associated with the abandonment of the subdermal implant of Etonogestrel in patients seen in Health District 03D01 of Azogues, during 2014-2017. Methodology. The sample included 234 patients, constituting the study population, selected at random, within the descriptive design. The sample was calculated with 95 % confidence, 4 % inference error. The data were obtained and analyzed with the SPSS Software, version 2015. The significant association was considered with a value of p < 0,005 Results. The age fluctuated between 13 and 46 years, 58.5 % were married, 49.1 % resided in the urban area. The prevalence of early removal of the implant was 33.3 % (95 % CI 26,98 - 39.02), and it was associated with alterations in menstrual bleeding that affected the quality of life (PR 3.9, 95 % CI 3 ,1 - 5,0, p < 0,001), weight increase> 10 kg (RP 3,5, 95 % CI 2,8 - 4,0, p < 0,001), severe headache (RP 3,7, 95 % CI 3,0 - 5,0, p < 0,001), pain at the insertion site (RP 3,1, 95 % CI 2,6 - 4,0, p 0,004) and pregnancy planning (RP 3,3, 95 % CI 2,7 - 4,0, p < 0,001). Conclusion. The prevalence of early discontinuation of the subdermal Etonogestrel implant and associated factors are similar to that reported in the literature.es_ES
dc.description.cityCuencaes_ES
dc.description.degreeEspecialista en Ginecología y Obstetriciaes_ES
dc.formatapplication/pdfes_ES
dc.identifier.urihttp://dspace.ucuenca.edu.ec/handle/123456789/31923
dc.language.isospaes_ES
dc.relation.ispartofseriesMEDGO;75
dc.subjectAnticoncepciónes_ES
dc.subjectImplante Subdérmicoes_ES
dc.subjectSalud Reproductivaes_ES
dc.subjectEfecto Secundarioes_ES
dc.subjectEspecialización En Ginecología Y Obstetriciaes_ES
dc.titlePrevalencia y factores asociados al abandono del implante subdérmico de Etonogestrel, Distrito 03D01, Azogues, 2014-2017es_ES
dc.typemasterThesises_ES
dc.ucuenca.id0300761921es_ES
dc.ucuenca.idautor0302397872es_ES
dc.ucuenca.paginacion65 páginases_ES

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
TESIS.pdf
Size:
1.95 MB
Format:
Adobe Portable Document Format
Description:
texto completo

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
19.88 KB
Format:
Item-specific license agreed upon to submission
Description: