Light intensity of the light-curing units in private clinics in the city of Cuenca, Ecuador

dc.contributor.advisorPalacios Astudillo, Iván Andrés
dc.contributor.authorAjila Bohórquez, Ana Mischell
dc.contributor.authorLalangui Matamoros, Joe Javier
dc.date.accessioned2022-04-19T19:23:56Z
dc.date.available2022-04-19T19:23:56Z
dc.date.issued2021-01-20
dc.description.abstractIntroduction: Light intensity emitted by the curing lamps represents an essential factor in the activation of photosensitive materials. The adequate supply of intensity, as well as the correct functioning of the device, it ensures a correct dental treatment. Objective: To know the light intensity, type, and fiber state of the curing lamps used in private dental offices in the city of Cuenca - Ecuador. Materials and methods: The cross-sectional descriptive study assessed the light intensity of 366 light-curing lamps from private clinics with the use of a Bluephase Meter II radiometer, besides the Likert-scale based evaluation of its type and condition. Data analysis was done with the software R v.3.2 and its interface R-Studio v.1.2. Results: Inadequate light intensities were observed in 18% of the total analyzed units. Inadequate light intensities corresponded at 46% of Halogen lamps, and 12% of LED units. Likewise, 17% of units presented fiber fracture, while 52% showed residues of biomaterials on it. The predominant diameter in the units was 8mm, representing 65% of the total of light-curing lamps analyzed. Conclusions: LED lamps presented adequate light intensities in higher proportion in comparison to halogen lamps. It was shown that the presence of fractures and residues decrease the intensity of the photocuring units. Furthermore, we indicate that a periodic control of the lightcuring units is necessary to prevent future problems in oral treatments.en_US
dc.description.cityCuencaen_US
dc.description.degreeOdontólogoen_US
dc.formatapplication/pdfen_US
dc.format.extent17 páginasen_US
dc.identifier.urihttp://dspace.ucuenca.edu.ec/handle/123456789/38810
dc.language.isospaen_US
dc.publisherUniversidad de Cuencaen_US
dc.relation.ispartofseriesODON;656
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.accessRightsopenAccessen_US
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectOdontologíaen_US
dc.subjectFotopolimerizaciónen_US
dc.subjectFibra ópticaen_US
dc.subjectRadiómetro dentalen_US
dc.subject.otherFotometríaen_US
dc.titleLight intensity of the light-curing units in private clinics in the city of Cuenca, Ecuadoren_US
dc.typeArticleen_US
dc.ucuenca.areaconocimientounescoamplio32 Ciencias Médicasen_US
dc.ucuenca.areaconocimientounescodetallado3311.03 Instrumentos para Odontologíaen_US
dc.ucuenca.areaconocimientounescoespecifico3213 Cirugíaen_US
dc.ucuenca.correspondenciaanita.ajilabohórquez@gmail.comen_US
dc.ucuenca.correspondenciajoejavierlm@gmail.comen_US
dc.ucuenca.id0104052386en_US
dc.ucuenca.idautor0704801976en_US
dc.ucuenca.idautor0704464981en_US
dc.ucuenca.responsablerecepcionArtiles Banguela Denisse Ceciliaen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Trabajo de titulación.pdf
Size:
318.58 KB
Format:
Adobe Portable Document Format
Description:
Versión presentada (texto completo)

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: