Eficacia antibacteriana de tres cementos selladores endodónticos frente al enterococcus faecalis

dc.contributor.advisorAbad Coronel, Dunia Elizabeth
dc.contributor.authorHeredia Veloz, David Marcelo
dc.date.accessioned2016-10-14T20:19:52Z
dc.date.available2016-10-14T20:19:52Z
dc.date.issued2016
dc.descriptionOBJETIVO: Este estudio tiene como objetivo la comparación de la eficacia antibacteriana sobre el Enterococcus faecalis, de tres cementos selladores de obturación utilizados en la terapia endodóntica, determinada mediante la medición del tamaño del halo inhibitorio. MATERIALES Y MÉTODOS: se realizó un estudio comparativo in vitro, en el cual se utilizó el método de difusión en el agar de Müller- Hinton. Se calculó una muestra de 10 replicaciones por cemento haciendo un total de 30 unidades de estudio (mediante el programa G Power 3.1). Los datos del halo inhibitorio fueron medidos en milímetros después de 24 horas de incubación, a una temperatura de 37°C, los resultados obtenidos se anotaron en una ficha elaborada por el autor, para posteriormente procesarlos mediante el análisis estadístico de Shapiro-Wilk, Kruskal-Wallis y U de Mann Withney. RESULTADOS: el sellador a base de resina epóxica (TOPSEAL) presentó un halo de inhibición de 7,7 mm, el sellador a base de hidróxido de calcio (SEALAPEX) provocó un halo inhibitorio de 6,0 mm y el sellador a base de óxido de zinc y eugenol (GROSSFAR) presentó un halo de inhibición de 8,4 mm, siendo el de mayor eficacia de los tres selladores utilizados en este estudio. CONCLUSIÓN: este estudio llegó a la conclusión que los selladores estudiados no son iguales respecto a eficacia antibacteriana contra el Enterococcus faecalises_ES
dc.description.abstractOBJETIVE: the aim of this study was the comparison of antibacterial efficacy of three endodontic sealers, used in endodontic therapy. The antibacterial efficacy of sealers was determinate by measuring the inhibitory halo against Enterococcus faecalis. MATERIALS AND METHODS: a comparative in vitro study was done; the method of agar diffusion of Müller- Hinton was used. A sample of 10 replications for each sealer was estimated with the help the program (G Power 3.1) the total of sample was the 30 units of study. The data of inhibitory halo was measured in millimeters after 24 hours, incubated a temperature of 37°C, the results was registered in a format developed by the author, later the results were processed by statistical analysis Shapiro-Wilk, Kruskal-Wallis and U de Mann Withney. RESULTS: the resin- based sealer (TOPSEAL) showed an inhibitory halo of 7.7 mm; the hydroxide of calcium – based sealer (SEALAPEX) was of 6 mm whereas the oxide of zinc and eugenol – based sealer showed an inhibitory halo of 8.4 mm, this inhibitory halo was the biggest in this study. CONCLUSION: this study concluded that the sealers used in this study are not equal in their antibacterial efficacy against Enterococcus faecalis.es_ES
dc.description.cityCuencaes_ES
dc.description.degreeODONTÓLOGOes_ES
dc.formatapplication/pdfes_ES
dc.identifier.urihttp://dspace.ucuenca.edu.ec/handle/123456789/25681
dc.language.isospaes_ES
dc.relation.ispartofseriesODON;593
dc.subjectEnterococcus Faecalises_ES
dc.subjectSelladores Endodonticoses_ES
dc.subjectEficacia Antibacterianaes_ES
dc.subjectHalo Inhibitorioes_ES
dc.titleEficacia antibacteriana de tres cementos selladores endodónticos frente al enterococcus faecalises_ES
dc.typebachelorThesises_ES
dc.ucuenca.id0102085297es_ES
dc.ucuenca.idautor0105539894es_ES
dc.ucuenca.paginacion79 páginases_ES

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
TESIS.pdf
Size:
2.38 MB
Format:
Adobe Portable Document Format
Description:
Texto Completo

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
19.88 KB
Format:
Item-specific license agreed upon to submission
Description: