Determinación preanestésica del volumen gástrico por ecografía en apendicectomías. Hospital José Carrasco Arteaga. Cuenca, 2020 – 2021

dc.audience.educationLevelTesis de Especialista en Anestesiologíaen_US
dc.contributor.advisorPalacios Reinoso, Carlos Santiago
dc.contributor.authorBenavides Calle, Daniela Fernanda
dc.date.accessioned2022-03-14T17:59:55Z
dc.date.available2022-03-14T17:59:55Z
dc.date.issued2022-03-14
dc.descriptionAntecedentes: la broncoaspiración de contenido gástrico es una grave complicación que puede ocurrir durante la anestesia general; sobre todo en cirugías de emergencia, como es el caso de las apendicectomías, donde el ayuno preoperatorio no siempre es confiable y se considera estómago lleno. El ultrasonido es una herramienta útil para medir el volumen gástrico, predecir el riesgo de broncoaspiración y optar por un manejo anestésico adecuado. Objetivo: determinar el volumen gástrico preanestésico por ecografía en pacientes que van a ser sometidos a apendicectomía en el Hospital José Carrasco Arteaga. Métodos: estudio observacional descriptivo. La población estuvo conformada por pacientes adultos sometidos a apendicectomías, en el Hospital José Carrasco. La muestra se calculó de acuerdo a un universo desconocido, obteniendo 174 participantes. Los resultados fueron procesados en SPSS V27, y expresados en medidas de frecuencia, tendencia central y dispersión de acuerdo al tipo de variable. Se empleó un histograma para una visualización general del comportamiento del volumen gástrico. Resultados: la mayoría de pacientes fueron hombres, entre 30 y 39 años, con sobrepeso y ASA 1. La media del tiempo de ayuno fue 9,5 horas. El 42,5% ingirieron por última vez líquidos claros. El volumen gástrico promedio fue de 41,88 ± 23,92 ml. El 21,3% presentaron estómago de riesgo y el 1,7% tienen alto riesgo de broncoaspiración. Conclusiones: el volumen gástrico medido por ecografía fue muy variable, la mayoría de pacientes presentaron bajo riesgo de aspiración y no se encontró asociación con ningún factor farmacológico ni patológico que alteren el vaciamiento gástrico.en_US
dc.description.abstractBackground: Breathing of gastric contents into the airways is a serious complication that can occur during local anesthesia; especially in emergency surgeries, such as appendectomies, where preoperative fasting is not always reliable and it is considerade full stomach. Ultrasound is a useful tool to measure gastric volume, predicting the risk of breathing into the airways, and to choose accurate anesthetic management. Objective: To determine the preanesthetic gastric volume by ultrasound in patients who are going to undergo appendectomy at the José Carrasco Arteaga Hospital. Methods: A descriptive observational study. The population consisted of adult patients undergoing appendectomy at the José Carrasco Hospital. The sample was calculated according to an unknown universe, obtaining 174 participants. The results were processed in SPSS V27, and expressed in measures of frequency, central tendency and dispersion according to the type of variable. A histogram was used for a general visualization of the behavior of the gastric volume. Results: the majority of patients were men, between 30 and 39 years old, overweight and ASA 1. The mean gastric volume was 41.88 ± 23.92 ml The average fasting time was 9.5 hours, 42.5% took clear liquids for the last time. 21.3% are considered to have “at risk stomach” condition and 1.7% have high risk of breathing into the airways. There was a change in anesthetic induction in 4.6%. Conclusions: the gastric volume measured by ultrasound was highly variable, the majority of patients had a low risk of aspiration and no association was found with any pharmacological or pathological factors that alter gastric emptying.en_US
dc.description.cityCuencaen_US
dc.description.degreeEspecialista en Anestesiologíaen_US
dc.formatapplication/pdfen_US
dc.format.extent50 páginasen_US
dc.identifier.urihttp://dspace.ucuenca.edu.ec/handle/123456789/38558
dc.language.isospaen_US
dc.publisherUniversidad de Cuencaen_US
dc.relation.ispartofseriesMEDA;108
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.accessRightsopenAccessen_US
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectMedicinaen_US
dc.subjectBroncoaspiraciónen_US
dc.subject.otherAnestesiologíaen_US
dc.titleDeterminación preanestésica del volumen gástrico por ecografía en apendicectomías. Hospital José Carrasco Arteaga. Cuenca, 2020 – 2021en_US
dc.typemasterThesisen_US
dc.ucuenca.areaconocimientounescoamplio32 Ciencias Médicasen_US
dc.ucuenca.areaconocimientounescodetallado3213.03 Anestesiologíaen_US
dc.ucuenca.areaconocimientounescoespecifico3213 Cirugíaen_US
dc.ucuenca.correspondenciadani.f2293@hotmail.comen_US
dc.ucuenca.id0102430766en_US
dc.ucuenca.idautor0302436548en_US
dc.ucuenca.responsablerecepcionMaza Margoth Elizabethen_US
dc.ucuenca.titulouniformeDETERMINACION PREANESTESICA DEL VOLUMEN GASTRICO POR ECOGRAFIA EN APENDICECTOMIAS. HOSPITAL JOSE CARRASCO ARTEAGA. CUENCA, 2020 – 2021en_US
dc.ucuenca.versionsubmittedVersionen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Trabajo de titulacion.pdf
Size:
701.61 KB
Format:
Adobe Portable Document Format
Description:
Versión presentada (texto completo)

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: