Determinación de los niveles basales de Co2 espirado mediante capnografía, en pacientes quirúrgicos. Hospital Vicente Corral Moscoso. Cuenca, 2019-2020

dc.audience.educationLevelTesis de Especialista en Anestesiologíaen_US
dc.contributor.advisorCevallos Sacoto, Francisco Antonio
dc.contributor.assessorMorales Sanmartín, Jaime Rodrigo
dc.contributor.authorTigre Cuenca, Daniela Soledad
dc.date.accessioned2021-07-09T18:58:41Z
dc.date.available2021-07-09T18:58:41Z
dc.date.issued2021-07-09
dc.descriptionIntroducción: En Anestesiología y en pacientes críticos es necesario mantener los niveles de dióxido de carbono (CO2) en parámetros normales, cuya alteración influye en la morbimortalidad. Se ha demostrado que los valores de presión de CO2 y de CO2 espirado (ETCO2) varían en dependencia de la presión atmosférica. En la ciudad de Cuenca a 2560 metros sobre el nivel de mar (ms.n.m), aún no existe un estudio que establezca los valores de normalidad. Objetivo: Determinar los niveles basales de CO2 espirado en pacientes quirúrgicos, en el Hospital Vicente Corral Moscoso. Metodología: Estudio observacional, descriptivo, con 534 pacientes sin comorbilidades, que se sometieron a cirugía en el Hospital Vicente Corral Moscoso de Cuenca Ecuador. Para la recolección de datos se usó termómetro, barómetro, sensor de humedad, monitor de signos vitales y capnógrafo; se registraron en un formulario, se analizaron en el software IBM SPSS versión 22 con estadígrafos descriptivos. Resultados: El promedio de ETCO2 espirado fue 28.36 ± 1.81 mmHg, IC 95% (28.277 – 28.434). La presión alveolar fue de 68.116 ± 3.897 IC 95% (28,277 - 28,435). Hubo diferencia significativa (p < 0.05) de las medias de CO2 según frecuencia respiratoria, tensión arterial media y si era cirugía electiva o de emergencia. Conclusiones: Existe concordancia con otros estudios que indican que a mayor altura los niveles de ETCO2 son menores, el rango obtenido podría ser tomado en cuenta como referencia para el adecuado manejo del ETCO2 en los habitantes de esta ciudad.en_US
dc.description.abstractIntroduction: In anesthesiology and in critically ill patients, it is necessary to maintain the levels of carbon dioxide (CO2) in normal parameters, whose alteration influences morbidity and mortality. The pressure values of CO2 and Exhaled CO2 (ETCO2) have been shown to vary depending on atmospheric pressure. In the city of Cuenca at 2560 meters above sea level (masl), there is still no study that establishes normal values. Objective: To determine the basal levels of expired CO2 in surgical patients at the Vicente Corral Moscoso Hospital. Methodology: An observational, descriptive study with 534 patients without comorbidities, who underwent surgery at the Vicente Corral Moscoso Hospital in Cuenca Ecuador. To collect data, a thermometer, barometer, humidity sensor, vital signs monitor and capnograph were used; they were recorded in a form, they were analyzed in the IBM SPSS version 22 software with descriptive statistics. Results: The mean expired ETCO2 was 28.36 ± 1.81 mmHg, 95% CI (28.277 - 28.434). Alveolar pressure was 68,116 ± 3,897 95% CI (28,277 - 28,435). There was a significant difference (p <0.05) in the CO2 means according to respiratory rate, mean arterial pressure and whether it was elective or emergency surgery. Conclusions: There is agreement with other studies that indicate that the higher the ETCO2 levels are lower, the range obtained could be taken into account as a reference for the adequate management of ETCO2 in the inhabitants of this geographical area.en_US
dc.description.cityCuencaen_US
dc.description.degreeEspecialista en Anestesiologíaen_US
dc.formatapplication/pdfen_US
dc.format.extent51 páginasen_US
dc.identifier.urihttp://dspace.ucuenca.edu.ec/handle/123456789/36448
dc.language.isospaen_US
dc.publisherUniversidad de Cuencaen_US
dc.relation.ispartofseriesMEDA;094
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.accessRightsopenAccessen_US
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectMedicinaen_US
dc.subjectPacientesen_US
dc.subjectCapnografía
dc.subjectRespiración artificial
dc.subject.otherAnestesiaen_US
dc.titleDeterminación de los niveles basales de Co2 espirado mediante capnografía, en pacientes quirúrgicos. Hospital Vicente Corral Moscoso. Cuenca, 2019-2020en_US
dc.typemasterThesisen_US
dc.type.senescytTesisen_US
dc.ucuenca.areaconocimientounescoamplio32 Ciencias Médicasen_US
dc.ucuenca.areaconocimientounescodetallado3213.03 Anestesiologíaen_US
dc.ucuenca.areaconocimientounescoespecifico3201 Ciencias Clínicasen_US
dc.ucuenca.correspondenciadtigrecczs5@gmail.comen_US
dc.ucuenca.id0104216973en_US
dc.ucuenca.idautor0104019492en_US
dc.ucuenca.responsablerecepcionArtiles Banguela Denisse Ceciliaen_US
dc.ucuenca.titulouniformeDETERMINACIÓN DE LOS NIVELES BASALES DE CO2 ESPIRADO MEDIANTE CAPNOGRAFÍA, EN PACIENTES QUIRÚRGICOS. HOSPITAL VICENTE CORRAL MOSCOSO. CUENCA, 2019-2020en_US
dc.ucuenca.versionsubmittedVersionen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
TESIS.pdf
Size:
1009.46 KB
Format:
Adobe Portable Document Format
Description:
Versión presentada (texto completo)

License bundle

Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed upon to submission
Description: