Logo Repositorio Institucional

Please use this identifier to cite or link to this item: http://dspace.ucuenca.edu.ec/handle/123456789/44401
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorHidalgo Cordero, Juan Fernando-
dc.contributor.authorTasambay Paucar, Elizabeth Alexandra-
dc.date.accessioned2024-03-21T13:53:19Z-
dc.date.available2024-03-21T13:53:19Z-
dc.date.issued2024-03-20-
dc.identifier.urihttp://dspace.ucuenca.edu.ec/handle/123456789/44401-
dc.descriptionEn este trabajo se aborda un exhaustivo estudio acerca de las fibras de totora y cabuya, que incluye aspectos que van desde su taxonomía hasta su proceso productivo, sus propiedades aislantes y su aplicabilidad en la arquitectura. A su vez, se proponen tres modelos de tableros aislantes, distribuidos en trece probetas, con el propósito de examinar su comportamiento térmico. Para ello, se llevaron a cabo ensayos de caracterización, como pruebas de conductividad térmica, absorción de humedad y densidad. La determinación del coeficiente de conductividad térmica (k) se llevó a cabo mediante dos metodologías diferentes. En la primera, se empleó un enfoque experimental siguiendo la metodología de los aparatos PASCO TD-8561. En contraste, la segunda se basó en el método para la conducción térmica en paredes compuestas en estado estable, utilizando el aparato HT11C. Ambos procedimientos se sustentan en la ley de Fourier como principio físico fundamental. Los resultados obtenidos revelan que las trece probetas exhiben un promedio de conductividad térmica que oscila entre 0,0371 y 0,078 W/m°K. Es destacable que las muestras 1A, 2A, 3A y 6A registran valores inferiores a 0,050 W/m°K, equiparables a los aislantes comúnmente empleados para mitigar el flujo de calor en construcciones. Este hallazgo sugiere que los materiales derivados de totora y cabuya no solo pueden rivalizar con los productos, sino que también presentan un menor impacto ambiental en términos de emisiones de CO2. De esta manera, la obtención y el proceso de producción contribuyen significativamente a la sostenibilidad medioambiental.en_US
dc.description.abstractIn this work, a comprehensive study of totora and cabuya fibers is undertaken, covering aspects ranging from their taxonomy to their production process, insulating properties, and their applicability in architecture. Additionally, three models of insulating panels are proposed, distributed across thirteen test samples, with the purpose of examining their thermal behavior. Characterization tests were conducted, including thermal conductivity, moisture absorption, and density tests. The determination of the thermal conductivity coefficient (k) was carried out using two different methodologies. In the first one, an experimental approach was employed following the methodology of the PASCO TD-8561 devices. In contrast, the second methodology was based on the method for thermal conduction in composite walls in steady state, using the HT11C device. Both procedures are based on Fourier's law as a fundamental physical principle. The results obtained reveal that the thirteen test samples exhibit an average thermal conductivity ranging between 0.0371 and 0.078 W/m°K. It is noteworthy that samples 1A, 2A, 3A, and 6A recorded values below 0.050 W/m°K, comparable to the insulators commonly used to mitigate heat flow in constructions. This finding suggests that materials derived from totora and cabuya can not only compete with conventional products but also have a lower environmental impact in terms of CO2 emissions. Thus, the extraction and production process significantly contribute to environmental sustainability.en_US
dc.description.uri0000-0002-2334-9569en_US
dc.formatapplication/pdfen_US
dc.format.extent105 páginasen_US
dc.language.isospaen_US
dc.publisherUniversidad de Cuencaen_US
dc.relation.ispartofTA;1327-
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectArquitecturaen_US
dc.subjectConductividad térmicaen_US
dc.subjectFibras vegetalesen_US
dc.subjectAislamiento térmicoen_US
dc.subjectAbsorción de humedaden_US
dc.subject.otherClasificación de la Investigación::Ingeniería Civil::Material de construcciónen_US
dc.titlePropuesta de tablero aislante con fibras naturales de totora y cabuyaen_US
dc.typesubmittedVersionen_US
dcterms.descriptionArquitectoen_US
dcterms.spatialCuenca, Ecuadoren_US
dc.rights.accessRightsopenAccessen_US
Appears in Collections:Tesis de Pregrado

Files in This Item:
File Description SizeFormat 
Trabajo-de-Titulación.pdfVersión presentada (texto completo)79.88 MBAdobe PDFView/Open


This item is protected by original copyright



This item is licensed under a Creative Commons License Creative Commons

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00