Logo Repositorio Institucional

Please use this identifier to cite or link to this item: http://dspace.ucuenca.edu.ec/handle/123456789/44280
Title: Security constrained AC dynamic transmission expansion planning considering reactive power requirements
Authors: Morquecho Salto, Edgar Gonzalo
Astudillo Salinas, Darwin Fabian
Torres Contreras, Santiago Patricio
metadata.dc.ucuenca.correspondencia: Torres Contreras, Santiago Patricio, santiago.torres@ucuenca.edu.ec
Keywords: Non convex optimization
Renewable energy
Reactive power planning
Metaheuristics
Dynamic transmission expansion planning
metadata.dc.ucuenca.areaconocimientofrascatiamplio: 2. Ingeniería y Tecnología
metadata.dc.ucuenca.areaconocimientofrascatidetallado: 2.2.1 Ingeniería Eléctrica y Electrónica
metadata.dc.ucuenca.areaconocimientofrascatiespecifico: 2.2 Ingenierias Eléctrica, Electrónica e Información
metadata.dc.ucuenca.areaconocimientounescoamplio: 07 - Ingeniería, Industria y Construcción
metadata.dc.ucuenca.areaconocimientounescodetallado: 0713 - Electricidad y Energia
metadata.dc.ucuenca.areaconocimientounescoespecifico: 071 - Ingeniería y Profesiones Afines
Issue Date: 2023
metadata.dc.ucuenca.volumen: Volumen 221
metadata.dc.source: Electric Power Systems Research
metadata.dc.identifier.doi: 10.1016/j.epsr.2023.109419
metadata.dc.type: ARTÍCULO
Abstract: 
The Transmission Network Expansion Planning problem (TNEP) can be modeled either as a static, a pseudo-dynamic, or a dynamic problem. Most of the existing formulations do not include reactive power planning within the TNEP problem, leading to sub-optimal designs leading to higher system costs in reality. This paper proposes a dynamic (multi-stage) non-convex formulation that optimizes the addition of transmission circuits and reactive power compensation devices, accounting for operational costs including losses. The planning is done considering security constraints using an AC model. As there are no similar research works to benchmark the outcomes, the results were compared with those obtained from the static and pseudo-dynamic approaches, showing that the proposed approach provides more economical solutions. It is also shown that better solutions are obtained when Reactive Power Planning (RPP) is considered in the problem formulation. An improved Differential Evolution (DE) and Continuous Population Based Incremental Learning (PBILc) hybrid solution method (IDE-PBILc) is proposed which drastically improves calculation time and robustness. Comparisons with two different state-of-the-art metaheuristics are performed for validation. The results were obtained for the Garver 6-bus, IEEE 24-bus, and the IEEE 118-bus systems. Even though in this work uncertainties are not considered, the proposed approach could be of particular use when studying systems with high renewable energy penetration scenarios, due to its computational efficiency.
URI: http://dspace.ucuenca.edu.ec/handle/123456789/44280
https://www.scopus.com/record/display.uri?eid=2-s2.0-85153681225&origin=resultslist&sort=plf-f&src=s&sid=66151562ece612043caa0282c9b68d75&sot=b&sdt=b&s=TITLE-ABS-KEY%28Security+constrained+AC+dynamic+transmission+expansion+planning+considering+reactive+power+requirements%29&sl=79&sessionSearchId=66151562ece612043caa0282c9b68d75&relpos=0
metadata.dc.ucuenca.urifuente: https://www.sciencedirect.com/journal/electric-power-systems-research/vol/221/suppl/C
ISSN: 0378-7796
Appears in Collections:Artículos

Files in This Item:
File SizeFormat 
documento.pdf410.87 kBAdobe PDFView/Open


This item is protected by original copyright



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00