Logo Repositorio Institucional

Por favor, use este identificador para citar o enlazar este ítem: http://dspace.ucuenca.edu.ec/handle/123456789/44144
Título : Housing Development through the BIM Methodology to Reach the Powerhouse Standard by Applying Rammed-Earth Techniques and Solar Energy
Autor: Astudillo Gomezcoello, Joan Alejandra
Zalamea Leon, Esteban Felipe
Orellana Castro, Daniel Alejandro
Correspondencia: Zalamea Leon, Esteban Felipe, esteban.zalamea@ucuenca.edu.ec
Palabras clave : Vernacular architecture
Photovoltaics
Powerhouse
Net-zero energy building
Área de conocimiento FRASCATI amplio: 2. Ingeniería y Tecnología
Área de conocimiento FRASCATI detallado: 2.1.2 Ingeniería Arquitectónica
Área de conocimiento FRASCATI específico: 2.1 Ingeniería Civil
Área de conocimiento UNESCO amplio: 07 - Ingeniería, Industria y Construcción
ÁArea de conocimiento UNESCO detallado: 0732 - Construcción e Ingeniería Civil
Área de conocimiento UNESCO específico: 073 - Arquitectura y Construcción
Fecha de publicación : 2024
Fecha de fin de embargo: 30-dic-2050
Volumen: Volumen 30, número 1
Fuente: Journal of Architectural Engineering
metadata.dc.identifier.doi: 10.1061/JAEIED.AEENG-1647
Tipo: ARTÍCULO
Abstract: 
As cities and economies grow, energy demands also grow, especially in developing countries, given the material production, construction, and operational processes of buildings and cities. Since the recent Powerhouse standard assumes that a building can generate as much energy as it will require during its lifespan, the present study aimed to implement this building standard in the Andean equatorial climate. For this purpose, a building energy model (BEM) integrated into a building information modeling (BIM) process design method was proposed, developing a prototype with vernacular technology, high solar potential, and local or regional data on embodied energy in accordance with a life cycle assessment (LCA) from cradle to grave. Solar potential estimations were complemented by system advisor model (SAM) tool projections. Because of the low energy content of the vernacular architecture proposal and prototype development with a high generation capacity, this standard can be met six times faster in the Andean equatorial climate than in extreme seasonal climates (8.53 years versus 60.0 years). The main goal of our research was to propose a methodological approach that integrates the BEM tool with vernacular concepts and materials and architectural formal criteria for high solar exploitation that, with background data from the literature, makes it possible to decipher the capability of the proposed energy standard.
URI : http://dspace.ucuenca.edu.ec/handle/123456789/44144
https://www.scopus.com/record/display.uri?eid=2-s2.0-85182608991&doi=10.1061%2fJAEIED.AEENG-1647&origin=inward&txGid=58f2f42ee01fd8d398e8bde0e283003e
URI Fuente: https://ascelibrary.org/journal/jaeied
ISSN : 1076-0431
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Tamaño Formato  
documento.pdf
  Until 2050-12-30
951.56 kBAdobe PDFVisualizar/Abrir     Solicitar una copia


Este ítem está protegido por copyright original



Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00