Logo Repositorio Institucional

Please use this identifier to cite or link to this item: https://dspace.ucuenca.edu.ec/handle/123456789/43040
Title: Evaluation of on-Site Sanitation Systems: Efficiency of Baffled Septic Tanks
Authors: Garcia Avila, Fausto Fernando
Aviles Añazco, Alex Manuel
Plaza Leon, Pablo Alejandro
Caraguay Palacios, Cesar Augusto
Keywords: Baffles
Wastewater treatment
Septic tanks
Nutrients
Decentralized treatment
metadata.dc.ucuenca.areaconocimientofrascatiamplio: 2. Ingeniería y Tecnología
metadata.dc.ucuenca.areaconocimientofrascatidetallado: 2.4.2 Ingeniería de Procesos Químicos
metadata.dc.ucuenca.areaconocimientofrascatiespecifico: 2.4 Ingeniería Química
metadata.dc.ucuenca.areaconocimientounescoamplio: 05 - Ciencias Físicas, Ciencias Naturales, Matemáticas y Estadísticas
metadata.dc.ucuenca.areaconocimientounescodetallado: 0521 - Ciencias Ambientales
metadata.dc.ucuenca.areaconocimientounescoespecifico: 052 - Medio Ambiente
Issue Date: 2023
metadata.dc.ucuenca.volumen: Volumen 16, número 3
metadata.dc.source: Journal of Engineering Science and Technology Review
metadata.dc.identifier.doi: 10.25103/jestr.163.15
metadata.dc.type: ARTÍCULO
Abstract: 
Domestic wastewater from homes without sewerage is discharged directly into the ground, rivers or streams, which generates health and pollution problems. Septic tanks are used as an on-site treatment by a significant fraction of the world's population. This study aimed to evaluate the efficiency of domestic wastewater treatment using septic tanks with baffles implemented in rural households. The septic tanks were built and evaluated as part of a research project, focused on decentralized domestic wastewater treatment systems at the rural level. The septic tanks operated with detention times of 4.44; 2.67 and 1.90 days. The data was obtained through five monitoring campaigns with a fortnightly frequency, taking water samples at the entrance and exit of each septic tank. After sample collection, concentration levels of BOD5, COD, total suspended solids (TSS), nitrates, and phosphates were determined according to Standard Methods for the Examination of Water and Wastewater. A BOD5 removal of 31.28±8.69%, COD removal of 30.52±7.89%, TSS removal of 39.39±11.90% was obtained, while there was an increase in nitrates of 41.41±3.85% and an increase in phosphates of 46.89± 36.77%. The removal values were affected by the retention time and the initial concentration of the parameters. The data could be useful in designing and operating on-site septic tanks, characterizing strictly domestic contamination, as well as incorporating them into future research or innovations related to single-family homes. Likewise, these data could be entered into the databases used for the evaluation of septic tanks with baffles.
URI: http://dspace.ucuenca.edu.ec/handle/123456789/43040
https://www.scopus.com/record/display.uri?eid=2-s2.0-85166165646&origin=resultslist&sort=plf-f&src=s&sid=5c773977ff2804a1c253923e924c46ad&sot=b&sdt=b&s=TITLE-ABS-KEY%28Evaluation+of+on-Site+Sanitation+Systems%3A+Efficiency+of+Baffled+Septic+Tanks%29&sl=91&sessionSearchId=5c773977ff2804a1c253923e924c46ad
metadata.dc.ucuenca.urifuente: http://www.jestr.org/
ISSN: 1791-9320
Appears in Collections:Artículos

Files in This Item:
File SizeFormat 
documento.pdf767.84 kBAdobe PDFView/Open


This item is protected by original copyright



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00