Título : Enhancing Energy Power Quality in Low-Voltage Networks Integrating Renewable Energy Generation: A Case Study in a Microgrid Laboratory
Otros títulos : Enhancing Energy Power Quality in Low-Voltage Networks Integrating Renewable Energy Generation: A Case Study in a Microgrid Laboratory
Autor: Iñiguez Moran, Vinicio Estuardo
Villa Avila, Edisson Andres
Ochoa Correa, Danny Vinicio
Palabras clave : Moving average
Low-pass filter
Microgrid
Power smoothing
Photovoltaic generation system
Monitoring control
Área de conocimiento FRASCATI amplio: 2. Ingeniería y Tecnología
Área de conocimiento FRASCATI detallado: 2.2.1 Ingeniería Eléctrica y Electrónica
Área de conocimiento FRASCATI específico: 2.2 Ingenierias Eléctrica, Electrónica e Información
Área de conocimiento UNESCO amplio: 07 - Ingeniería, Industria y Construcción
ÁArea de conocimiento UNESCO detallado: 0713 - Electricidad y Energia
Área de conocimiento UNESCO específico: 071 - Ingeniería y Profesiones Afines
Fecha de publicación : 2023
Volumen: Volumen 16, número 14
Fuente: Energies
metadata.dc.identifier.doi: 10.3390/en16145386
Tipo: ARTÍCULO
Abstract: 
Nowadays, energy decarbonization due to integrating renewable energy sources presents important challenges to overcome. The intermittent nature of photovoltaic systems reduces power quality by producing voltage variations and frequency deviations in electrical system networks, es pecially in weak and isolated distribution systems in developing countries. This paper presents a power smoothing method for improving the low-pass filter and moving average for grid-connected photovoltaic systems. This novel method includes state-of-charge monitoring control of the super capacitor’s energy storage system to reduce the fluctuations of photovoltaic power at the point of common coupling. A case study for a microgrid in a high-altitude city in Ecuador is presented with exhaustive laboratory tests using real data. This research aims to improve energy power quality in electrical distribution systems to cope with the growth of renewable penetration. The results demonstrate significant power quality and stability improvements achieved through the proposed method. For instance, the power smoothing method effectively reduced power fluctuations by 16.7% with the low-pass filter, 14.05% with the ramp-rate filter, and 9.7% with the moving average filter.
Resumen : 
URI : http://dspace.ucuenca.edu.ec/handle/123456789/43037
https://www.scopus.com/record/display.uri?eid=2-s2.0-85166196306&origin=resultslist&sort=plf-f&src=s&sid=854d81a042bffec4341423770680cf5d&sot=b&sdt=b&s=TITLE-ABS-KEY%28Enhancing+Energy+Power+Quality+in+Low-Voltage+Networks+Integrating+Renewable+Energy+Generation%3A+A+Case+Study+in+a+Microgrid+Laboratory%29&sl=149&sessionSearchId=854d81a042bffec4341423770680cf5d
URI Fuente: https://www.mdpi.com/1996-1073/16/14/5386
ISSN : 1996-1073
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Tamaño Formato  
documento.pdf10.02 MBAdobe PDFVisualizar/Abrir


Este ítem está protegido por copyright original



Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00