Title: Analysis of Passive Strategies in Traditional Vernacular Architecture
Authors: Quesada Molina, Juan Felipe
Moscoso Martinez, Jose Francisco
metadata.dc.ucuenca.correspondencia: Moscoso Martinez, Jose Francisco, pericomoscoso@ucacue.edu.ec
Quesada Molina, Juan Felipe, felipe.quesada@ucuenca.edu.ec
Keywords: Passive design strategies
Dynamic thermal simulations
Building energy performance
Indoor thermal environment
Vernacular housing
metadata.dc.ucuenca.areaconocimientofrascatiamplio: 2. Ingeniería y Tecnología
metadata.dc.ucuenca.areaconocimientofrascatidetallado: 2.1.2 Ingeniería Arquitectónica
metadata.dc.ucuenca.areaconocimientofrascatiespecifico: 2.1 Ingeniería Civil
metadata.dc.ucuenca.areaconocimientounescoamplio: 07 - Ingeniería, Industria y Construcción
metadata.dc.ucuenca.areaconocimientounescodetallado: 0731 - Arquitectura y Urbanismo
metadata.dc.ucuenca.areaconocimientounescoespecifico: 073 - Arquitectura y Construcción
Issue Date: 2023
metadata.dc.ucuenca.volumen: Volumen 13, número 8
metadata.dc.source: Buildings
metadata.dc.identifier.doi: 10.3390/buildings13081984
metadata.dc.type: ARTÍCULO
Abstract: 
Vernacular architecture constitutes a rich source of information and ancestral knowledge and could become a key resource for sustainable development. Its passive design strategies effectively respond to local climatic and weather conditions, using locally sourced materials for the construction of its supporting structures and enveloping elements, as well as spatial organization and the incor- poration of a buffer area (courtyard) that optimize the use of renewable resources. This qualitative study analyzes a traditional housing typology with a central courtyard located in the Historic Center of Azogues, Ecuador. In situ monitoring was conducted to evaluate the case study’s interior thermal comfort in different building spaces. Using the open-source software Open Studio and EnergyPlus, a simulation model was built to assess the annual thermal performance of the house. Field records were used to verify the effectiveness of the strategies that responded to the location’s climatic conditions. The analysis of the passive strategies used in the selected house included natural ventilation, solar protection, and thermal insulation, which depended on various aspects of the building, such as its location, the internal space’s arrangement, and the design of openings (doors and windows), among others. The thermal simulations revealed that the traditional house located in the Historic Center of Azogues was well adapted to the local climate, although the interior thermal comfort was not entirely satisfactory.
URI: http://dspace.ucuenca.edu.ec/handle/123456789/42610
https://www.mdpi.com/2075-5309/13/8/1984
metadata.dc.ucuenca.urifuente: https://www.mdpi.com/journal/buildings
ISSN: 2075-5309
Appears in Collections:Artículos

Files in This Item:
File SizeFormat 
documento.pdf7.46 MBAdobe PDFView/Open


This item is protected by original copyright



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00