Logo Repositorio Institucional

Por favor, use este identificador para citar o enlazar este ítem: http://dspace.ucuenca.edu.ec/handle/123456789/42586
Título : Fracture Resistance Analysis of CAD/CAM Interim Fixed Prosthodontic Materials: PMMA, Graphene, Acetal Resin and Polysulfone
Autor: Abad Coronel, Cristian Gustavo
Calle Cabrera, Viviana Carolina
Abril Orellana, Gabriela Alexandra
Paltán Zhingre, César Antonio
Fajardo Seminario, Jorge Isaac
Correspondencia: Abad Coronel, Cristian Gustavo, cristian.abad@ucuenca.edu.ec
Palabras clave : Interim restorations
PMMA
Graphene
Polysulfphone
Acetalic resin
Mechanical properties
CAD CAM materials
Área de conocimiento FRASCATI amplio: 3. Ciencias Médicas y de la Salud
Área de conocimiento FRASCATI detallado: 3.2.15 Odontología
Área de conocimiento FRASCATI específico: 3.2 Medicina Clínica
Área de conocimiento UNESCO amplio: 09 - Salud y Bienestar
ÁArea de conocimiento UNESCO detallado: 0911 - Estudios Dentales
Área de conocimiento UNESCO específico: 091 - Salud
Fecha de publicación : 2023
Volumen: Volumen 15, número 7
Fuente: Polymers
metadata.dc.identifier.doi: 10.3390/polym15071761
Tipo: ARTÍCULO
Abstract: 
The aim of this study was to evaluate and compare the fracture resistance of temporary restorations made of polymethylmethacrylate (PMMA), graphene-modified PMMA (GRA), acetal resin (AR) and polysulfone (PS) obtained by a subtractive technique (milling) using a computer-aided design and manufacturing (CAD/CAM) system of a three-unit fixed dental prosthesis (FDP). Methods: Four groups of ten samples were fabricated for each material. Each specimen was characterized by a compression test on a universal testing machine, all specimens were loaded to fracture and the value in Newtons (N) was recorded by software connected to the testing machine. The fracture mode was evaluated on all samples using a stereomicroscope. Results: There were statistically significant differences (p value < 0.005) between PMMA and the other three materials (PMMA: 1302.71 N; GRA: 1990.02 N; RA: 1796.20 N; PS: 2234.97). PMMA presented a significantly lower value than the other materials, and PS showed the highest value. GRA and RA presented a similar range of values but they were still higher than those of PMMA. Conclusions: GRA, RA and PS are presented as valid options within the range of interim milled restorative materials and as alternatives to PMMA.
URI : https://www.scopus.com/record/display.uri?eid=2-s2.0-85152858921&origin=resultslist&sort=plf-f&src=s&sid=fd3a0d804d7f3f677f2c0d70125db932&sot=b&sdt=b&s=TITLE-ABS-KEY%28Fracture+Resistance+Analysis+of+CAD%2FCAM+Interim+Fixed+Prosthodontic+Materials%3A+PMMA%2C+Graphene%2C+Acetal+Resin+and+Polysulfone%29&sl=98&sessionSearchId=fd3a0d804d7f3f677f2c0d70125db932
URI Fuente: https://www.mdpi.com/journal/polymers
ISSN : 2073-4360
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Tamaño Formato  
documento.pdf2.92 MBAdobe PDFVisualizar/Abrir


Este ítem está protegido por copyright original



Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00