Please use this identifier to cite or link to this item:
http://dspace.ucuenca.edu.ec/handle/123456789/41862
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.advisor | Peñafiel Martínez, Nadia Rosalía | - |
dc.contributor.author | Guaillas Gualán, Marcelo de Jesús | - |
dc.date.accessioned | 2023-05-09T21:15:13Z | - |
dc.date.available | 2023-05-09T21:15:13Z | - |
dc.date.issued | 2023-05-09 | - |
dc.identifier.uri | http://dspace.ucuenca.edu.ec/handle/123456789/41862 | - |
dc.description | Antecedentes: La línea de Tuffier es una referencia empleada cotidianamente para guiar la punción lumbar, sin embargo, esta no es confiable pues se puede influenciar por factores como edad, talla, índice de masa corporal, embarazo, entre otros. Objetivos: Determinar mediante ultrasonido la localización de la línea de Tuffier en pacientes sometidas a cesárea con anestesia neuroaxial y relacionar factores asociados. Método: El presente trabajo es un estudio analítico transversal, conformado por 267 pacientes sometidas a cesárea bajo anestesia neuroaxial en el hospital Vicente Corral Moscoso de Cuenca Ecuador, entre enero a diciembre del 2021, se recolectó los datos en un formulario, se usó el programa SPSS versión 22 y para analizar estadística descriptiva e inferencial. Resultados: Al usar ultrasonido, el 94% de la población de estudio tuvo una demarcación de la línea de Tuffier por encima de L4. Se determinó que la talla y el índice de masa corporal son factores que influyen, las mujeres con altura menor de 1,52 metros tuvieron una asociación con la demarcación sobre L3 con el método de palpación (OR 153,14 IC = 20,826 – 1126,099 p <0,001) y el índice de masa corporal mayor a 25 kg/m2 (OR 2,114 IC = 1,180 – 3,787 p = 0,001). Conclusiones: El método de palpación puede no ser confiable en gestantes para la determinación del espacio de aplicación de la anestesia neuroaxial, al determinar por ultrasonografía la localización por sobre L4 se asoció con una menor talla de la gestante. | en_US |
dc.description.abstract | Background: The Tuffier line is a reference used daily to guide lumbar puncture, however, it is not entirely reliable as it can be influenced by factors such as age, height, body mass index, pregnancy, among other factors. Objectives: Determine the location of the Tuffier line in patients undergoing cesarean section with neuraxial anesthesia and relate associated factors using ultrasound. Method: The present work is a cross-sectional analytical study, made up of 267 patients undergoing cesarean section under neuraxial anesthesia at the Vicente Corral Moscoso hospital in Cuenca Ecuador, between January and December 2021, the data was collected in a form, the program was used. SPSS version 22 and to analyze descriptive and inferential statistics. Results: Using ultrasound, 94% of the study population had a demarcation of Tuffier's line above L4. It was determined that height and body mass index are factors that influence, women with a height less than 1.52 meters had an association with the demarcation on L3 with the palpation method (OR 153.14 CI = 20.826 - 1126.099 p <0.001), body mass index greater than 25 kg/m2(OR 2.114 CI = 1.180 – 3.787 p = 0.001). Conclusions: The palpation method may not be reliable in pregnant women to determine the space for the application of neuraxial anesthesia, when determining by ultrasound the location above L4 was associated with a smaller height of the pregnant woman. | en_US |
dc.description.uri | 0000-0002-3898-4784 | en_US |
dc.format | application/pdf | en_US |
dc.format.extent | 43 páginas | en_US |
dc.language.iso | spa | en_US |
dc.publisher | Universidad de Cuenca | en_US |
dc.relation.ispartofseries | MEDA;116 | - |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.subject | Medicina | en_US |
dc.subject | Embarazo | en_US |
dc.subject | Ultrasonografía | en_US |
dc.subject | Cesárea | en_US |
dc.subject.other | Anestesia | en_US |
dc.title | Determinación de la línea de tuffier y sus factores asociados en pacientes programadas para cesárea bajo anestesia neuroaxial guiada por ultrasonografía. Hospital Vicente Corral Moscoso. Cuenca 2021 | en_US |
dc.type | masterThesis | en_US |
dc.description.degree | Especialista en Anestesiología | en_US |
dc.description.city | Cuenca | en_US |
dc.ucuenca.version | submittedVersion | en_US |
dc.ucuenca.areaconocimientounescoamplio | 32 Ciencias Médicas | en_US |
dc.ucuenca.areaconocimientounescoamplio | 32 Ciencias Médicas | en_US |
dc.ucuenca.areaconocimientounescoespecifico | 3213 Cirugía | en_US |
dc.ucuenca.areaconocimientounescoespecifico | 3213 Cirugía | en_US |
dc.ucuenca.areaconocimientounescodetallado | 3213.03 Anestesiología | en_US |
dc.ucuenca.areaconocimientounescodetallado | 3213.03 Anestesiología | en_US |
dc.ucuenca.titulouniforme | DETERMINACION DE LA LINEA DE TUFFIER Y SUS FACTORES ASOCIADOS EN PACIENTES PROGRAMADAS PARA CESAREA BAJO ANESTESIA NEUROAXIAL GUIADA POR ULTRASONOGRAFIA. HOSPITAL VICENTE CORRAL MOSCOSO. CUENCA 2021 | en_US |
dc.rights.accessRights | openAccess | en_US |
dc.ucuenca.responsablerecepcion | Carrión Román Daniel Ramiro | en_US |
dc.audience.educationLevel | Tesis de Especialista en Anestesiología | en_US |
Appears in Collections: | Tesis Especializaciones |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Trabajo-de-Titulación.pdf | Versión presentada (texto completo) | 722.8 kB | Adobe PDF | View/Open |
This item is protected by original copyright |
This item is licensed under a Creative Commons License
Centro de Documentacion Regional "Juan Bautista Vázquez" | ||||||||||
|