Logo Repositorio Institucional

Por favor, use este identificador para citar o enlazar este ítem: http://dspace.ucuenca.edu.ec/handle/123456789/40974
Título : Modeling an isolated hybrid wind-diesel power system for performing frequency control studies. A case of study: San Cristobal Island, Galapagos–Ecuador
Autor: Martínez González, Sergio
Ochoa Correa, Danny Vinicio
Correspondencia: Ochoa Correa, Danny Vinicio, danny.ochoac@alumnos.upm.es
Palabras clave : Wind power integration
Load frequency control
Power system modeling
Wind-diesel power system
Área de conocimiento FRASCATI amplio: 2. Ingeniería y Tecnología
Área de conocimiento FRASCATI detallado: 2.2.1 Ingeniería Eléctrica y Electrónica
Área de conocimiento FRASCATI específico: 2.2 Ingenierias Eléctrica, Electrónica e Información
Área de conocimiento UNESCO amplio: 07 - Ingeniería, Industria y Construcción
ÁArea de conocimiento UNESCO detallado: 0713 - Electricidad y Energia
Área de conocimiento UNESCO específico: 071 - Ingeniería y Profesiones Afines
Fecha de publicación : 2019
Volumen: Volumen 17, número 5
Fuente: IEEE Latin America Transactions
metadata.dc.identifier.doi: 10.1109/TLA.2019.8891946
Tipo: ARTÍCULO
Abstract: 
From a technical and ecological point of view, standalone wind-diesel power generation has been proven to be one of the most effective solutions in electrification in remote populated locations. However, some technical aspects that characterize those systems such as the small size of conventional power generators, high share of wind energy, low consumption levels, and the lack of energy storage equipment, might make the operation and control tasks difficult due to the low stability margin. A real case that supports the previous statement is the San Cristobal wind-diesel power system (Galapagos Islands-Ecuador), whose undoubted environmental and economic benefits are notoriously contrasted by certain technical challenges that grid operators have to deal with. During the windiest season of 2015, many blackouts were reported on the island. These were originated by the trip of frequency relays of generation units whose causes are still unknown. In order to provide an analysis tool that allows to study the dynamics of most relevant variables of systems with these characteristics during a power contingency and to identify the possible causes that lead to a certain frequency event, this paper proposes a modeling procedure based on the load frequency control scheme, within the primary frequency regulation time-frame, along with its implementation in MATLAB/Simulink®. The complete model is validated by using real data measured in field tests in the island power system as well as technical information provided by the grid-operators.
URI : http://dspace.ucuenca.edu.ec/handle/123456789/40974
https://www.scopus.com/record/display.uri?eid=2-s2.0-85075032128&origin=resultslist&sort=plf-f&src=s&st1=Modeling+an+Isolated+Hybrid+Wind-Diesel+Power+System+for+Performing+Frequency+Control+Studies.+A+Case+of+Study%3a+San+Cristobal+Island%2cGalapagos%e2%80%93Ecuador&sid=48850818408dc1d996ba222ba6925066&sot=b&sdt=b&sl=166&s=TITLE-ABS-KEY%28Modeling+an+Isolated+Hybrid+Wind-Diesel+Power+System+for+Performing+Frequency+Control+Studies.+A+Case+of+Study%3a+San+Cristobal+Island%2c+Galapagos%e2%80%93Ecuador%29&relpos=0&citeCnt=4&searchTerm=
URI Fuente: https://ieeexplore.ieee.org/xpl/RecentIssue.jsp?punumber=9907
ISSN : 1548-0992
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Tamaño Formato  
documento.pdf805.41 kBAdobe PDFVisualizar/Abrir


Este ítem está protegido por copyright original



Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00