Logo Repositorio Institucional

Please use this identifier to cite or link to this item: http://dspace.ucuenca.edu.ec/handle/123456789/40939
Title: Frequency control issues in power systems: the effect of high share of wind energy
Authors: Ochoa Correa, Danny Vinicio
Martínez González, Sergio
metadata.dc.ucuenca.correspondencia: Ochoa Correa, Danny Vinicio, danny.ochoac@alumnos.upm.es
Keywords: Inertial response
Load frequency control
Wind power integration
metadata.dc.ucuenca.areaconocimientofrascatiamplio: 2. Ingeniería y Tecnología
metadata.dc.ucuenca.areaconocimientofrascatidetallado: 2.2.1 Ingeniería Eléctrica y Electrónica
metadata.dc.ucuenca.areaconocimientofrascatiespecifico: 2.2 Ingenierias Eléctrica, Electrónica e Información
metadata.dc.ucuenca.areaconocimientounescoamplio: 07 - Ingeniería, Industria y Construcción
metadata.dc.ucuenca.areaconocimientounescodetallado: 0713 - Electricidad y Energia
metadata.dc.ucuenca.areaconocimientounescoespecifico: 071 - Ingeniería y Profesiones Afines
Issue Date: 2018
metadata.dc.ucuenca.volumen: Volumen 16, número 7
metadata.dc.source: IEEE Latin America Transactions
metadata.dc.identifier.doi: 10.1109/TLA.2018.8447360
metadata.dc.type: ARTÍCULO
Abstract: 
Technological advances, low production costs, efficiency, emission-free operation, and abundance of supply are some of the factors that have strongly motivated the use of renewable energy sources for electrical energy production in recent years. The economy of scale has placed wind generation well ahead of other renewable technological alternatives, a fact that is reflected in the significant increase in operating units in many power systems. However, the inherent characteristics of wind such as: natural intermittence and non-dispatchability, might negatively impact the power system performance in terms of frequency stability by reducing the inertial resources as well as the regulation capability. This paper presents a comprehensive analysis of power system frequency control issues, its theoretical basis, and time-domain simulations that illustrate each of the electromagnetic and mechanical phenomena involved. Additionally, a methodology for evaluating the minimum amount of inertial resources in a power system, so that the frequency response complies with a given grid code under various wind penetration scenarios, is proposed. Finally, the proposal is assessed by performing time-domain simulations in MATLAB/Simulink® using two approaches for representing the behavior of the power system: the detailed modeling of the components and the load frequency control scheme.
URI: http://dspace.ucuenca.edu.ec/handle/123456789/40939
https://www.scopus.com/record/display.uri?eid=2-s2.0-85052739226&origin=resultslist&sort=plf-f&src=s&st1=Frequency+Control+Issues+in+Power+Systems%3a+the+Effect+of+High+Share+of+Wind+Energy&sid=af3f925c2b48d854468127d05eda3544&sot=b&sdt=b&sl=97&s=TITLE-ABS-KEY%28Frequency+Control+Issues+in+Power+Systems%3a+the+Effect+of+High+Share+of+Wind+Energy%29&relpos=0&citeCnt=4&searchTerm=
metadata.dc.ucuenca.urifuente: https://latamt.ieeer9.org/index.php/transactions/issue/archive
ISSN: 1548-0992
Appears in Collections:Artículos

Files in This Item:
File SizeFormat 
documento.pdf908.43 kBAdobe PDFView/Open


This item is protected by original copyright



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00