Title: Extended simplified electro-mechanical model of a variable-speed wind turbine for grid Integration studies: emulation and validation on a microgrid Lab
Authors: Arevalo Cordero, Paúl
Ochoa Correa, Danny Vinicio
Martínez González, Sergio
metadata.dc.ucuenca.correspondencia: Martínez González, Sergio, sergio.martinez@upm.es
Keywords: Microgrid lab
Power system analysis
Variable-speed wind turbine
Grid integration studies
Power electronic converter
metadata.dc.ucuenca.areaconocimientofrascatiamplio: 2. Ingeniería y Tecnología
metadata.dc.ucuenca.areaconocimientofrascatidetallado: 2.11.2 Otras Ingenierias y Tecnologías
metadata.dc.ucuenca.areaconocimientofrascatiespecifico: 2.11 Otras Ingenierias y Tecnologías
metadata.dc.ucuenca.areaconocimientounescoamplio: 07 - Ingeniería, Industria y Construcción
metadata.dc.ucuenca.areaconocimientounescodetallado: 0713 - Electricidad y Energia
metadata.dc.ucuenca.areaconocimientounescoespecifico: 071 - Ingeniería y Profesiones Afines
Issue Date: 2022
metadata.dc.ucuenca.volumen: Volumen 11, número 23
metadata.dc.source: Electronics
metadata.dc.identifier.doi: 10.3390/electronics11233945
metadata.dc.type: ARTÍCULO
Abstract: 
The energy transition towards renewable energies is crucial for the sustainable development of a society based on hydrocarbons. The current level of penetration and growth of wind energy in electric power systems is evident and many researchers have presented new methods for simulating and representing the electrical and mechanical characteristics of variable-speed wind turbines. However, complete mathematical models developed and implemented, for example, in MATLAB/Simulink® software, require significant computational efforts that could make grid studies impractical when its scale tends to increase. To contribute to facing this issue, this paper proposes an extended simplified model for a variable-speed wind turbine that considers the dynamic behavior of its mechanical system and includes an approximate representation of the power electronic converter. This approach broadens the scope of studies related to grid frequency control and power quality (fast-frequency response, primary frequency control, and voltage control, among others), considerably reducing the computational burden. Several validations of the proposed simplified model are presented, including comparisons with a doubly fed induction generator-based wind turbine model (phasor type) from the MATLAB/Simulink® library, and laboratory experiments under controlled conditions. The results show a good fit of the proposed simplified model to the MATLAB/Simulink® model, with minimal delays about 3% of the wind turbine inertia constant. Moreover, with the proposal, the computational time is reduced by up to 80% compared to a detailed model. This time reduction is achieved without penalizing the numerical accuracy and the estimation quality of the real behavior of the variable-speed wind turbine.
URI: http://dspace.ucuenca.edu.ec/handle/123456789/40827
https://www.scopus.com/record/display.uri?eid=2-s2.0-85143650686&doi=10.3390%2felectronics11233945&origin=inward&txGid=b51884993df37727b087418f30331f5b
metadata.dc.ucuenca.urifuente: https://www.mdpi.com/
ISSN: 2079-9292
Appears in Collections:Artículos

Files in This Item:
File SizeFormat 
documento.pdf8.69 MBAdobe PDFView/Open


This item is protected by original copyright



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00