Logo Repositorio Institucional

Please use this identifier to cite or link to this item: http://dspace.ucuenca.edu.ec/handle/123456789/40688
Title: Comparative analysis of HESS (battery/supercapacitor) for power smoothing of PV/HKT, simulation and experimental analysis
Authors: Cano Ortega, Antonio
Jurado Melguizo, Francisco
Benavides Padilla, Dario Javier
Arevalo Cordero, Wilian Paul
Keywords: Power smoothing
Battery
Hydrokinetic turbine
Supercapacitor
Photovoltaic
metadata.dc.ucuenca.areaconocimientofrascatiamplio: 2. Ingeniería y Tecnología
metadata.dc.ucuenca.areaconocimientofrascatidetallado: 2.2.1 Ingeniería Eléctrica y Electrónica
metadata.dc.ucuenca.areaconocimientofrascatiespecifico: 2.2 Ingenierias Eléctrica, Electrónica e Información
metadata.dc.ucuenca.areaconocimientounescoamplio: 07 - Ingeniería, Industria y Construcción
metadata.dc.ucuenca.areaconocimientounescodetallado: 0713 - Electricidad y Energia
metadata.dc.ucuenca.areaconocimientounescoespecifico: 071 - Ingeniería y Profesiones Afines
Issue Date: 2022
metadata.dc.ucuenca.volumen: Volumen 549
metadata.dc.source: Journal of Power Sources
metadata.dc.identifier.doi: 10.1016/j.jpowsour.2022.232137
metadata.dc.type: ARTÍCULO
Abstract: 
Photovoltaic and hydrokinetic systems are increasing their penetration in electrical distribution systems. This leads to problems of power fluctuations due to the intermittence of renewable sources that could compromise the stability and quality of the power grid. To address this issue, this paper presents a feasibility study of three power smoothing methods for a photovoltaic-hydrokinetic system using laboratory equipment to optimally replicate the real behavior of this type of hybrid system. The proposed algorithms are based on a hybrid storage system with supercapacitors and lithium-ion batteries, several analyzes are presented based on technical and economic parameters. The results demonstrate the feasibility of power smoothing methods for real systems, the comparison between the algorithms highlights the characteristics of the Enhanced Linear Exponential Smoothing Method, reducing the energy cost and regulating the point of common coupling voltage. Moreover, the sensitivity studies show that the energy exchange with the utility grid is affected according to the variations in the capacity of the batteries and the response to power smoothing can decrease or improve depending on the size of the supercapacitors.
URI: http://dspace.ucuenca.edu.ec/handle/123456789/40688
https://www.scopus.com/record/display.uri?eid=2-s2.0-85138825443&doi=10.1016%2fj.jpowsour.2022.232137&origin=inward&txGid=c5c3fc8bc94bd960b8c1432a038f3665
metadata.dc.ucuenca.urifuente: https://www.sciencedirect.com/journal/journal-of-power-sources/vol/549/suppl/C
ISSN: 378-7753
Appears in Collections:Artículos

Files in This Item:
File SizeFormat 
documento.pdf12.89 MBAdobe PDFView/Open


This item is protected by original copyright



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00