Logo Repositorio Institucional

Please use this identifier to cite or link to this item: http://dspace.ucuenca.edu.ec/handle/123456789/40425
Title: Analysis of the mesh resolution of an .STL exported from an intraoral scanner file
Authors: Atria, Pablo J
Abad Coronel, Cristian Gustavo
Blatz, Markus
Pendola, Martin
Mena Cordova, Nancy Cecilia
Cornejo, Julián
Romero Muñoz, Carla Estefania
metadata.dc.ucuenca.correspondencia: Atria, Pablo J, atria.pablo@gmail.com
Keywords: Dental materials
CAD CAM
Digital dentistry
metadata.dc.ucuenca.areaconocimientofrascatiamplio: 3. Ciencias Médicas y de la Salud
metadata.dc.ucuenca.areaconocimientofrascatidetallado: 3.2.15 Odontología
metadata.dc.ucuenca.areaconocimientofrascatiespecifico: 3.2 Medicina Clínica
metadata.dc.ucuenca.areaconocimientounescoamplio: 09 - Salud y Bienestar
metadata.dc.ucuenca.areaconocimientounescodetallado: 0911 - Estudios Dentales
metadata.dc.ucuenca.areaconocimientounescoespecifico: 091 - Salud
Issue Date: 2022
metadata.dc.ucuenca.embargoend: 27-Dec-2050
metadata.dc.ucuenca.volumen: volumen 4, número 5
metadata.dc.source: Journal of Esthetic and Restorative Dentistry
metadata.dc.identifier.doi: 10.1111/jerd.12889
metadata.dc.type: ARTÍCULO
Abstract: 
Objectives: This study aimed to provide information on the accuracy of exported digital files with the different resolutions available in the CEREC 4.6.2 software obtained by means of an intraoral scanner (IOS), in addition to establishing differences between materialized models with different exported resolutions, and how these different exported files can influence finite element analysis (FEA) simulations. Materials and Methods: The upper complete arch of 10 patients was scanned through an IOS (CEREC Omnicam 1.0/Dentsply Sirona). Files of three resolution meshes digitalized by a CAD software (Cerec SW, 4.6.2) high, medium and low (IOSH, IOSM, and IOSL) were exported. Each file was evaluated by a software (NETFABB) about the number of triangles obtained and compared with the number announced by the manufacturer. Also, with a superimposition with a specialized software (GEOMAGIC X), the digital models were compared. The files of each resolution were printed (Sprintray 3D Printer), and the printed models were scanned with IOS (Omnicam 1.0) and compared with the control group (intraoral scanned high-resolution file, IOSH). FEA simulations were imported into COMSOL and analyzed under different loading conditions. Results: The number of exported triangles coincided with that reported by the manufacturer. The digital models from files of different resolution did not show significant differences (less than 1.5 um) between each other. Models printed (H, M, L) from files of the same resolution mesh (H, M, L) did not show significant differences between them either in partial measures of the arch and neither in the complete arch. FEA showed significant differences in stress concentration between different exported models. Clinical Significance: Digital models can be exported and printed in three resolutions of the mesh, without differences clinically significative. On the other hand, for future FEA applications further research should be performed in order to determine the optimal number of triangles.
URI: http://dspace.ucuenca.edu.ec/handle/123456789/40425
https://www.scopus.com/inward/record.uri?eid=2-s2.0-85125571393&doi=10.1111%2fjerd.12889&partnerID=40&md5=25fe91e996e13b626e50ba364764fd40
metadata.dc.ucuenca.urifuente: https://onlinelibrary.wiley.com/journal/17088240
ISSN: 1708-8240
Appears in Collections:Artículos

Files in This Item:
File Description SizeFormat 
prePostPrint.pdfprePostPrint3.27 MBAdobe PDFView/Open
documento.pdf
  Until 2050-12-27
document3.27 MBAdobe PDFView/Open Request a copy


This item is protected by original copyright



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00