Logo Repositorio Institucional

Please use this identifier to cite or link to this item: http://dspace.ucuenca.edu.ec/handle/123456789/39855
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorBravo Calderón, Manuel Estuardo-
dc.contributor.authorBernal Pinos, Marco Vinicio-
dc.date.accessioned2022-09-16T22:41:35Z-
dc.date.available2022-09-16T22:41:35Z-
dc.date.issued2022-09-16-
dc.identifier.urihttp://dspace.ucuenca.edu.ec/handle/123456789/39855-
dc.descriptionobjetivo de este estudio fue describir el borde Wala, mediante la utilización de archivos STL y DICOM para posteriormente contrastar los resultados con los valores dados por los autores Will Andrews y Larry Andrews y de esa manera cuál es el método diagnóstico que más se acerca a la realidad. En este estudio descriptivo observacional se incluyeron 36 participantes, en un rango de edad de 23 a 33 años, estudiantes universitarios, a quienes se les realizó los estudios de tomografías computarizadas CBCT (archivos DICOM) y escaneos intraorales para la obtención de modelos STL. Se usaron 2 software Meshmixer para los STL y 3D Slicer para los CBCT. En ambos métodos diagnósticos, para la medición del borde WALA se determinó: el punto del eje Facial (FA), ubicado en el parte más prominente del centro coronal vestibular en los premolares y en el centro del surco mesiovestibular en los primeros molares; el punto WALA, ubicado perpendicular al plano oclusal en la unión mucogingival. Los datos de las mediciones obtenidas se guardaron en el programa Microsoft office Excel 2019. El promedio de las mediciones obtenidas en Meshmixer así como en 3D Slicer fue obtenido utilizando el software SPSS. Los resultados se exponen en tablas. Los valores obtenidos entre el punto FA y la cresta WALA fueron progresivos en sentido anteroposterior, siendo menor para los premolares y mayor en el primer molar. No se encontraron discrepancias estadísticamente significativas para los valores obtenidos en archivos STL del escáner, pero sí para los modelos DICOM de los CBCT en especial porque estos últimos sólo evalúan tejidos duros. Los valores obtenidos se asemejan en gran medida a los valores descritos por Will Andrews, sin embargo, estos difieren significativamente en relación a la unidad de análisis de archivos DICOM los mismos que carecen de un respaldo científico para ser tomados en cuenta como una medición diagnóstica del borde WALA. Algunas de las diferencias de valores obtenidos para las mediciones del borde WALA entre diferentes poblaciones de estudio pueden deberse a que varios estudios utilizan el método manual o convencional y otros el método digital e incluso el mismo escáner o software empleado en la medición digital de modelos puede hacer que haya discrepancias en las mediciones.en_US
dc.description.abstractThe objective of this study was to describe the WALA edge, using STL and DICOM files, contrasting the results with the values given by the authors Will Andrews and Larry Andrews and thus which diagnostic method is the closest to reality. This descriptive observational study included 36 participants, ranging in age from 23 to 33 years, university students, who underwent CBCT computed tomography studies (DICOM files) and intraoral scans to obtain STL models. Two Meshmixer software were used for the STL and 3D Slicer for the CBCT. In both diagnostic methods, for the measurement of the WALA edge, the following was determined: the point of the facial axis (FA), located in the most prominent part of the vestibular coronal center in premolars and in the center of the mesiovestibular sulcus in first molars; the WALA point, located perpendicular to the occlusal plane at the mucogingival junction. The data of the measurements obtained were saved in the Microsoft office Excel 2019 program. The average of the measurements obtained was analyzed using SPSS software for Meshmixer values as well as in 3D Slicer. The results are presented in tables. Statistically significant discrepancies were found for the values obtained from the STL files compared to the CBCT DICOM files especially because the latter only evaluate hard tissues for WALA edge measurements. The values obtained largely resemble the values described by Will Andrews, however, these differ significantly in relation to the unit of analysis of DICOM files the same that lack scientific support to be taken into account as a diagnostic measurement of the WALA edge. Some of the differences in values obtained for WALA edge measurements between different study populations may be due to the fact that several studies use the manual or conventional method and others the digital method and even the same scanner or software used in the digital measurement of models may cause discrepancies in the measurements.en_US
dc.formatapplication/pdfen_US
dc.format.extent20 páginasen_US
dc.language.isoengen_US
dc.publisherUniversidad de Cuencaen_US
dc.relation.ispartofseriesODONOR;032-
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectOdontologíaen_US
dc.subjectRadiología dentalen_US
dc.subject.otherOrtodonciaen_US
dc.titleDescription of the WALA edge measured in STL and DICOM filesen_US
dc.typebachelorThesisen_US
dc.description.degreeEspecialista en Ortodonciaen_US
dc.description.cityCuencaen_US
dc.ucuenca.id0102137460en_US
dc.ucuenca.idautor0301506069en_US
dc.ucuenca.versionsubmittedVersionen_US
dc.type.senescytProyecto de investigaciónen_US
dc.ucuenca.areaconocimientounescoamplio32 Ciencias Médicasen_US
dc.ucuenca.correspondenciafiftycet@hotmail.comen_US
dc.ucuenca.areaconocimientounescoespecifico3213 Cirugíaen_US
dc.ucuenca.areaconocimientounescodetallado3213.13 Ortodoncia-Estomatologíaen_US
dc.ucuenca.titulouniformeDescription of the WALA edge measured in STL and DICOM filesen_US
dc.rights.accessRightsopenAccessen_US
dc.ucuenca.responsablerecepcionMaza Margoth Elizabethen_US
dc.audience.educationLevelTesis de Especialidad en Ortodonciaen_US
Appears in Collections:Tesis Especializaciones

Files in This Item:
File Description SizeFormat 
Trabajo de Titulacion.pdfVersión presentada (texto completo)901.11 kBAdobe PDFThumbnail
View/Open


This item is protected by original copyright



This item is licensed under a Creative Commons License Creative Commons

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00