Logo Repositorio Institucional

Please use this identifier to cite or link to this item: http://dspace.ucuenca.edu.ec/handle/123456789/39745
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorGarcía Ávila, Fausto Fernando-
dc.contributor.authorPatiño Ullauri, Mateo Roberto-
dc.contributor.authorVallejo Chuchuca, Bryan Alexander-
dc.date.accessioned2022-09-12T17:08:41Z-
dc.date.available2022-09-12T17:08:41Z-
dc.date.issued2022-08-12-
dc.identifier.urihttp://dspace.ucuenca.edu.ec/handle/123456789/39745-
dc.descriptionEl presente trabajo fue realizado en la planta de potabilización de la Junta Administradora de Agua Potable Regional Bayas (JAAPRB), el estudio estuvo orientado a evaluar la dosificación de policloruro de aluminio (PAC) sobre el rendimiento de la coagulación-floculación, para lo cual se realizaron pruebas de jarras con el uso de este coagulante en conjunto a polímero catiónico (PC) durante los meses de agosto y septiembre de 2021 así como febrero y marzo de 2022 abarcando un amplio rango de turbiedad del agua cruda. Con los resultados obtenidos en las pruebas de jarras se elaboró la curva de dosificación de PAC en base a tres criterios analizados, los cuáles correspondieron al análisis del rango completo de turbiedad registrado, rango menor a 500 NTU y rango mayor a 500 NTU, y también se determinó la dosis óptima de PC. Para la evaluación del proceso de coagulación-floculación se determinó un modelo matemático que describa la turbiedad del agua después del proceso de sedimentación en función de los parámetros turbiedad, pH y temperatura del agua cruda que ingresa al proceso de tratamiento, mediante la aplicación de la metodología de superficie de respuesta (MSR). Los resultados obtenidos indicaron que el promedio del porcentaje de remoción de la turbiedad del agua cruda en el desarrollo de las pruebas de jarras fue de 93.73% en un rango de turbiedad de 6.23 a 6030 NTU. Además, se encontró que existe un beneficio económico anual para la JAAPRB de aproximadamente $872.10 asociado a la reducción en la adquisición del producto químico PAC para la potabilización del agua cruda. De manera análoga, la curva de dosificación permite a los operarios establecer la dosis óptima de PAC para un valor de turbiedad específico, lo cual asegura y mejora el sistema de potabilización de agua, al igual que permite cumplir con los requerimientos establecidos en la normativa de calidad del agua INEN 1108.en_US
dc.description.abstractThe present work was carried out at the Bayas Regional Drinking Water Board (JAAPRB) drinking water treatment plant, the study was aimed towards at evaluating the dosage of aluminum polychloride (PAC) on the coagulation-flocculation performance, for which jar tests were conducted with the use of this coagulant in conjunction with cationic polymer (PC) during the months of August and September 2021 and February and March 2022, covering a wide range of raw water turbidity. With the results obtained in the jug tests, the PAC dosage curve was elaborated based on three analyzed criteria, which corresponded to the analysis of the complete range of turbidity recorded, range less than 500 NTU and range greater than 500 NTU, and the optimum PC dosage was also determined. For the evaluation of the coagulation-flocculation process, a mathematical model was determined to describe the turbidity of the water after the sedimentation process as a function of the parameters turbidity, pH and temperature of the raw water entering the treatment process, by applying the response surface methodology (RSM). The results obtained indicated that the average percentage of turbidity removal of the raw water in the development of the jug tests was 93.73% in a turbidity range of 6.23 to 6030 NTU. In addition, it was found that there is an annual economic benefit to the JAAPRB of approximately $872.10 associated with the reduction in the purchase of the PAC chemical for the potabilization of raw water. Similarly, the dosage curve allows operators to establish the optimal PAC dosage for a specific turbidity value, which ensures and improves the water purification system, as well as allows compliance with the requirements established in the INEN 1108 water quality standard.en_US
dc.formatapplication/pdfen_US
dc.format.extent136 páginasen_US
dc.language.isospaen_US
dc.publisherUniversidad de Cuencaen_US
dc.relation.ispartofseriesTIA;214-
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectIngeniería Ambientalen_US
dc.subjectFloculaciónen_US
dc.subjectSedimentaciónen_US
dc.subjectAgua potableen_US
dc.subjectCantón Azoguesen_US
dc.subject.otherPotabilización del aguaen_US
dc.titleEvaluación de la dosificación de policloruro de aluminio sobre el rendimiento de la coagulación – floculación en la planta potabilizadora de la Junta Administradora de Agua Potable Regional Bayasen_US
dc.typebachelorThesisen_US
dc.description.degreeIngeniero Ambientalen_US
dc.description.cityCuencaen_US
dc.ucuenca.id0301454617en_US
dc.ucuenca.idautor0105812812en_US
dc.ucuenca.idautor0106423064en_US
dc.ucuenca.versionsubmittedVersionen_US
dc.ucuenca.areaconocimientounescoamplio25 Ciencias de la Tierra y del Espacioen_US
dc.ucuenca.correspondenciamateop9911@gmail.comen_US
dc.ucuenca.correspondenciabryanvallejo44@gmail.comen_US
dc.ucuenca.areaconocimientounescoespecifico2508 Hidrologíaen_US
dc.ucuenca.areaconocimientounescodetallado2508.11 Calidad de las Aguasen_US
dc.rights.accessRightsopenAccessen_US
dc.ucuenca.responsablerecepcionNaula Morocho María de Lourdesen_US
Appears in Collections:Tesis de Pregrado

Files in This Item:
File Description SizeFormat 
Trabajo-de-Titulación.pdfVersión presentada (texto completo)8.42 MBAdobe PDFThumbnail
View/Open


This item is protected by original copyright



This item is licensed under a Creative Commons License Creative Commons

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00