Logo Repositorio Institucional

Por favor, use este identificador para citar o enlazar este ítem: http://dspace.ucuenca.edu.ec/handle/123456789/39468
Título : Use of battery energy storage systems to enhance the frequency stability of an islanded microgrid based on hybrid photovoltaic-diesel generation
Autor: Ponce Minaya, Edwin Bernardo
Pazmiño Ordoñez, Ivan Patricio
Pico Mera, Hugo Adrian
Ochoa Correa, Danny Vinicio
Correspondencia: Pazmiño Ordoñez, Ivan Patricio, ivan.pazmino.ordonez@gmail.com
Palabras clave : Primary frequency control
Battery energy storage system
Microgrid
Photovoltaic generation
Synchronous generation
Área de conocimiento FRASCATI amplio: 2. Ingeniería y Tecnología
Área de conocimiento FRASCATI detallado: 2.2.1 Ingeniería Eléctrica y Electrónica
Área de conocimiento FRASCATI específico: 2.2 Ingenierias Eléctrica, Electrónica e Información
Área de conocimiento UNESCO amplio: 07 - Ingeniería, Industria y Construcción
ÁArea de conocimiento UNESCO detallado: 0713 - Electricidad y Energia
Área de conocimiento UNESCO específico: 071 - Ingeniería y Profesiones Afines
Fecha de publicación : 2021
Fecha de fin de embargo: 30-dic-2050
Volumen: Volumen 379
Fuente: Lecture Notes in Networks and Systems
metadata.dc.identifier.doi: 10.1007/978-3-030-94262-5_5
Editor: Springer Science and Business Media Deutschland GmbH
Ciudad: 
Ambato
Tipo: ARTÍCULO DE CONFERENCIA
Abstract: 
Primary frequency control in power systems is becoming more difficult as levels of non-synchronous generation grow. This paper explores how implementing a control strategy based on the concept of virtual inertia, supported by the use of battery energy storage systems (BESS), might positively impact frequency stability of the grid. Particularly, this work centers its effort on islanded microgrids based on hybrid generation: photovoltaic and diesel. This paper presents a methodology for representing an islanded-power system equipped with photovoltaic (PV), diesel generators, and BESS, the latter with a virtual frequency control feature devised to improve the resilience of the system in terms of frequency after a contingency occurs. The proposed methodology is designed as an analysis tool to help in the survey and decision making in the planning and operation of systems with these characteristics. This methodology and its implementation are used to test an electrical power system facing a continuous power imbalance caused by the PV-power intermittence to assess how the frequency varies when the virtual inertia control system based on BESS is enabled or not. Matlab-Simulink is used as a simulation environment. The numerical results achieved with the model show the benefits of implementing the virtual inertia control characteristics in the BESS in terms of both reducing frequency fluctuations and reducing the time-derivative of frequency under normal operating conditions.
URI : http://dspace.ucuenca.edu.ec/handle/123456789/39468
http://www.scopus.com/inward/record.url?eid=2-s2.0-85124133935&partnerID=MN8TOARS
URI Fuente: https://www.scopus.com/record/display.uri?eid=2-s2.0-85124133935&origin=inward&txGid=d027ee063f79756aece29098c9b8af73&featureToggles=FEATURE_NEW_DOC_DETAILS_EXPORT:1
ISBN : 978-303094261-8
ISSN : 2367-3370
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
prePostPrint.pdfprePostPrint389.52 kBAdobe PDFVista previa
Visualizar/Abrir
documento.pdf
  Until 2050-12-30
document389.53 kBAdobe PDFVisualizar/Abrir     Solicitar una copia


Este ítem está protegido por copyright original



Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00