Logo Repositorio Institucional

Please use this identifier to cite or link to this item: http://dspace.ucuenca.edu.ec/handle/123456789/39390
Title: MQTT based event detection system for structural health monitoring of buildings
Authors: Placencia León, José Sebastián
Jimenez Pacheco, Juan Carlos
Gonzalez Martinez, Santiago Renan
Muñóz Calle, Milton Rodrigo
Palacios Serrano, Ivan Santiago
Samaniego Galindo, Victor Hugo
metadata.dc.ucuenca.correspondencia: Gonzalez Martinez, Santiago Renan, santiago.gonzalezm@ucuenca.edu.ec
Keywords: WSN
Event detection
Operational Modal Analysis
Structural Health
IoT
MQTT
metadata.dc.ucuenca.areaconocimientofrascatiamplio: 2. Ingeniería y Tecnología
metadata.dc.ucuenca.areaconocimientofrascatidetallado: 2.2.1 Ingeniería Eléctrica y Electrónica
metadata.dc.ucuenca.areaconocimientofrascatiespecifico: 2.2 Ingenierias Eléctrica, Electrónica e Información
metadata.dc.ucuenca.areaconocimientounescoamplio: 07 - Ingeniería, Industria y Construcción
metadata.dc.ucuenca.areaconocimientounescodetallado: 0714 - Electrónica y Automatización
metadata.dc.ucuenca.areaconocimientounescoespecifico: 071 - Ingeniería y Profesiones Afines
Issue Date: 2022
metadata.dc.ucuenca.embargoend: 31-Dec-2050
metadata.dc.ucuenca.volumen: Vol. 405
metadata.dc.source: Lecture Notes in Networks and Systems
metadata.dc.identifier.doi: 10.1007/978-3-030-96043-8_5
Publisher: Springer Science y Business Media Deutschland GmbH
metadata.dc.description.city: 
Quito
metadata.dc.type: ARTÍCULO DE CONFERENCIA
Abstract: 
Structural Health Monitoring (SHM) consists in a fundamental research field which aim to evaluate the current status of an infrastructure with the main purpose to identify damages and prevent catastrophic events. This paper presents an SHM solution that implements an automatic system based on the MQTT protocol and IoT devices for detecting seismic events. In particular, the architecture consists of a set of accelerometer sensors which communicate by means of a decentralized network topology (i.e., an Ad hoc Network configuration). Moreover, the system has the capacity to transmit the information about the events detected in real-time using cloud services. In order to verify the proper operation, the system was deployed on an actual building and the information acquired by the sensors was registered along four months. In this context, a relevant event detected was selected for analyzing the dynamic response of the building during a seism. Results show that the acceleration values increase as a function of the building height. Regarding the seismic event analyzed, the RMS values of acceleration identified on the basement were 0.26, 0.22, and 0.22 cm/s2 and in the case of the eighth floor were 1.18, 1.33, and 0.59 cm/s2 for the longitudinal, transverse, and vertical axes, respectively. Additionally, a first assessment regarding the structural health status of the building was performed through the OMA methodology (Operational Modal Analysis). Specifically, the FDD (Frequency Domain Decomposition) mechanism was used to determine the first four frequencies and its respective vibration modes.
URI: http://dspace.ucuenca.edu.ec/handle/123456789/39390
https://www.scopus.com/record/display.uri?eid=2-s2.0-85125286933&origin=resultslist&sort=plf-f&src=s&st1=MQTT+Based+Event+Detection+System+for+Structural+Health+Monitoring+of+Buildings&sid=a4e3ce8e11456a33baab3880e5795946&sot=b&sdt=b&sl=94&s=TITLE-ABS-KEY%28MQTT+Based+Event+Detection+System+for+Structural+Health+Monitoring+of+Buildings%29&relpos=0&citeCnt=0&searchTerm=&featureToggles=FEATURE_NEW_DOC_DETAILS_EXPORT:1
metadata.dc.ucuenca.urifuente: https://www.springer.com/series/15179
ISBN: 978-303096042-1
ISSN: 2367-3370
Appears in Collections:Artículos

Files in This Item:
File Description SizeFormat 
prePostPrint.pdfprePostPrint1.31 MBAdobe PDFThumbnail
View/Open
documento.pdf
  Until 2050-12-31
document263.52 kBAdobe PDFView/Open Request a copy


This item is protected by original copyright



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00