Logo Repositorio Institucional

Por favor, use este identificador para citar o enlazar este ítem: http://dspace.ucuenca.edu.ec/handle/123456789/38195
Título : Seismic performance of steel moment frames considering the effects of column-base hysteretic behavior and gravity framing system
Autor: Pozo Ocampo, Paul Sebastian
Torres Rodas, Pablo
Astudillo Carpio, Bryam Xavier
Flores Solano, Francisco Xavier
Correspondencia: Torres Rodas, Pablo, patorresr@usfq.edu.ec
Palabras clave : Hysteretic behavior
Moment frames
Column base
Seismic performance
Steel moment frames
Área de conocimiento FRASCATI amplio: 2. Ingeniería y Tecnología
Área de conocimiento FRASCATI detallado: 2.1.3 Ingeniería en Construcción
Área de conocimiento FRASCATI específico: 2.1 Ingeniería Civil
Área de conocimiento UNESCO amplio: 07 - Ingeniería, Industria y Construcción
ÁArea de conocimiento UNESCO detallado: 0732 - Construcción e Ingeniería Civil
Área de conocimiento UNESCO específico: 073 - Arquitectura y Construcción
Fecha de publicación : 2021
Volumen: Volumen 144
Fuente: Soil Dynamics and Earthquake Engineering
metadata.dc.identifier.doi: 10.1016/j.soildyn.2021.106654
Tipo: ARTÍCULO
Abstract: 
This paper presents a parametric study conducted on five Steel Moment Frames (SMFs) varying in height (2-, 4-, 8-, 12-, and 20- story) to assess the interactive effect of the column base hysteretic behavior, continuous gravity columns and partially restrained gravity beam-column connections in their seismic performance. The frame response is examined through sophisticated Nonlinear Time History (NTH) and Nonlinear Static Pushover (NSP) analyses conducted as per FEMAp695 methodology. For each SMF, a range of base connection strengths (and their corresponding rotational stiffnesses) accompanied by different levels of gravity columns rigidity and gravity connection strengths are assigned, resulting in a total of 80 model simulations. Two collapse/failure limit states are formulated for the assessment 1) sidesway collapse defined as per FEMAp695; and 2) column-base connection failure, defined as base rotations exceeding a 0.05 rad threshold. Results from the simulations indicate that the gravity framing system profoundly affects the behavior of the SMFs analyzed by reducing their probability of collapse. In this manner, the seismic demands for the design of column-base connections can be reduced safely, incorporating their high deformation capacity as part of the energy dissipative mechanisms. Potential design implications are discussed, and limitations, as well as lines for future research, are outlined
URI : http://dspace.ucuenca.edu.ec/handle/123456789/38195
https://www.scopus.com/record/display.uri?eid=2-s2.0-85101659279&doi=10.1016%2fj.soildyn.2021.106654&origin=inward&txGid=aa99cf56a9503db220af31d701fdc37f&featureToggles=FEATURE_NEW_DOC_DETAILS_EXPORT:1#indexed-keywords
URI Fuente: https://www.sciencedirect.com/journal/soil-dynamics-and-earthquake-engineering/vol/144/suppl/C
ISSN : 0267-7261
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
documento.pdfdocument15.05 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está protegido por copyright original



Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00