Logo Repositorio Institucional

Please use this identifier to cite or link to this item: http://dspace.ucuenca.edu.ec/handle/123456789/37953
Full metadata record
DC FieldValueLanguage
dc.contributor.advisorZalamea León, Esteban Felipe-
dc.contributor.authorMontalvo Parrales, Daniela Elizabeth-
dc.contributor.authorCalle Loza, Jhonatan Patricio-
dc.date.accessioned2022-02-04T13:59:54Z-
dc.date.available2022-02-04T13:59:54Z-
dc.date.issued2022-02-04-
dc.identifier.urihttp://dspace.ucuenca.edu.ec/handle/123456789/37953-
dc.descriptionLa presente investigación parte de la alta demanda energética constante que requiere una vivienda unifamiliar emplazada en clima tropical ecuatorial para sustentar los consumos eléctricos habituales y alcanzar el confort térmico en su interior. Para ello, se revisó una serie de bibliografías y se realizó un levantamiento de información en sitio, así como también la recopilación digital de las planillas del consumo eléctrico. Una vez caracterizada la vivienda y su entorno, se plantea una propuesta de rediseño similar al caso de estudio manteniendo su emplazamiento. Sumado a ello, se aplican estrategias pasivas de diseño en busca del estándar Net Zero como ventilación cruzada, cubierta y fachada ventilada, patio interior y protecciones contra la radiación solar. Posteriormente, a través de herramientas informáticas como DesignBuilder y Ecotec, se proceden a realizar los análisis bioclimáticos del caso de estudio complementado con los datos reflejados en las planillas eléctricas de la vivienda unifamiliar en dos periodos: mensual y anual correspondiente a la etapa de pre- pandemia y pandemia actual para luego realizar las mismas simulaciones bioclimáticas en el rediseño, demostrando un cambio significativo lo cual se refleja en la reducción del consumo energético comparado a la demanda que genera la vivienda existente. Con los resultados antes mencionados, se calculó mediante la herramienta System Advisor Model (SAM) que, para abastecer el consumo base del rediseño se requiere un total de 9 paneles PV (estándar Net Zero). Sin embargo, debido al área disponible en la cubierta, se propone el estándar Plus Energy House con 18 paneles, los cuales abastecen adicionalmente la demanda que genera un vehículo eléctrico y dos scooter. Finalmente, en busca de alcanzar el estándar Plus Energy House máximo se instalan 22 paneles PV, cubriendo así la capacidad máxima de la cubierta y disminuyendo la dependencia de recursos fósiles.en_US
dc.description.abstractThis research is based on the constant high energy demand that a single-family home located in a tropical equatorial climate requires to sustain the usual electrical consumptions and achieve interior thermal comfort. To perform this study, a series of bibliographies were reviewed and a survey of information was carried out onsite; additionally, a digital review of the electrical grids was performed. Once the house and its surroundings had been defined, a redesign proposal was put forward, maintaining the location. In search of the Net Zero standard, passive design strategies were applied, including cross ventilation, a ventilated roof and facade, an indoor courtyard, and solar radiation protections. Subsequently, through computer tools such as DesignBuilder and Ecotec, bioclimatic analyses were carried out, supplemented with the data reflected in the electrical grids of the single- family home in two periods: monthly and annually, corresponding to pre-pandemic conditions and the current pandemic stage. These tools served to replicate the same bioclimatic simulations in the redesign and demonstrated a significant change; this was reflected by the reduction of energy consumption compared to the demand generated by the existing home. With the aforementioned results, and by using the System Advisor Model (SAM) tool, in order to supply the base consumption of the redesign, a total of 9 PV panels (Net Zero standard) are required. However, due to the available area on the roof, the Plus Energy House standard of 18 panels were proposed, which would supply enough additional energy to power an electric vehicle and two scooters. In order to reach the maximum Plus Energy House standard, 22 PV panels would be installed, which would cover the maximum capacity of the roof and reduce dependence on fossil resources.en_US
dc.formatapplication/pdfen_US
dc.format.extent160 páginasen_US
dc.language.isospaen_US
dc.publisherUniversidad de Cuencaen_US
dc.relation.ispartofseriesTA;1141-
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectArquitecturaen_US
dc.subjectEnergía renovableen_US
dc.subjectEnergía solaren_US
dc.subjectConstrucciónen_US
dc.subject.otherViviendasen_US
dc.titleIncorporación fotovoltaica y estrategias pasivas para lograr máximo aprovisionamiento y alto estándar energético en clima tropical ecuatorialen_US
dc.typebachelorThesisen_US
dc.description.degreeArquitectoen_US
dc.description.cityCuencaen_US
dc.ucuenca.id0102125952en_US
dc.ucuenca.idautor1312564790en_US
dc.ucuenca.idautor1400436992en_US
dc.ucuenca.embargoend2024-04-10-
dc.ucuenca.versionsubmittedVersionen_US
dc.ucuenca.areaconocimientounescoamplio62 Ciencias de las Artes y las Letrasen_US
dc.ucuenca.correspondenciadanieliz_9652@hotmail.comen_US
dc.ucuenca.correspondenciajhonitasjc1204@gmail.comen_US
dc.ucuenca.areaconocimientounescoespecifico6201 Arquitecturaen_US
dc.ucuenca.areaconocimientounescodetallado6201.01 Diseño Arquitectónicoen_US
dc.rights.accessRightsopenAccessen_US
dc.ucuenca.responsablerecepcionLeón Bravo Diana Alexandraen_US
Appears in Collections:Tesis de Pregrado

Files in This Item:
File Description SizeFormat 
Trabajo de titulación.pdfAcceso restringido (versión presentada)39 MBAdobe PDFThumbnail
View/Open


This item is protected by original copyright



This item is licensed under a Creative Commons License Creative Commons

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00