Please use this identifier to cite or link to this item:
http://dspace.ucuenca.edu.ec/handle/123456789/37288
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.advisor | Minchala Ávila, Luis Ismael | - |
dc.contributor.advisor | Astudillo Salinas, Darwin Fabián | - |
dc.contributor.author | Carrión Portilla, Paúl Gustavo | - |
dc.contributor.author | Montalván Astudillo, David Andrés | - |
dc.date.accessioned | 2021-11-05T18:12:00Z | - |
dc.date.available | 2021-11-05T18:12:00Z | - |
dc.date.issued | 2021-11-05 | - |
dc.identifier.uri | http://dspace.ucuenca.edu.ec/handle/123456789/37288 | - |
dc.description | A mediados de diciembre de 2019, en la ciudad de Wuhan, China, se reportan los primeros casos del virus respiratorio infeccioso COVID-19. El COVID- 19, según la Organización Mundial de la Salud (WHO), es una enfermedad respiratoria infecciosa causada por un virus perteneciente a la gran familia CoV (Coronavirus). Los síntomas varían su intensidad para cada ser humano, desde un cuadro clínico leve que no requiere cuidados específicos, hasta síntomas severos que pudiesen conllevar una serie de enfermedades graves que necesiten tratamiento respiratorio intensivo, y en el peor de los casos la muerte. Toda esta situación obliga a que el personal médico tenga que decidir si los pacientes son aptos para acceder a los distintos tratamientos de soporte vital de acuerdo a la “gravedad e intensidad de los recursos”, entre ellos el uso de ventiladores mecánicos. No obstante, la creación de nuevos dispositivos médicos para aliviar la saturación, es posible, es por esto que la construcción de ventiladores portátiles de bajo costo se presenta como una solución importante y factible. En este trabajo, se presenta el proceso para la implementación de un modelo de ventilador mecánico asistido. El modelo fue desarrollado con base en la investigación recopilada durante la pandemia por médicos italianos y el MIT. Este ventilador permite que pacientes con síntomas menos severos de Covid-19 puedan ser atendidos por especialistas de la salud menos experimentados. Todo esto ayuda mientras el resto de recursos es usado en pacientes con cuadros clínicos severos. En la implementación se obtuvo un funcionamiento satisfactorio del dispositivo además de haber logrado el abaratamiento de costos en su construcción. Se logró la compresión de la bolsa de resucitación manual mediante la variación del volumen tidal, la cual está diseñada para variar en un rango entre 100 y 800 ml. Así mismo, el modo asistido tiene mayor precisión para valores de volumen tidal entre 400 y 500 ml y para un RR de 1.2 Brpm. | en_US |
dc.description.abstract | In mid-December 2019, in the city of Wuhan, China, the first cases of the infectious respiratory virus COVID-19 were reported. COVID-19, according to the World Health Organization (WHO), is an infectious respiratory disease caused by a virus belonging to the large CoV family (Coronavirus). The symptoms vary in intensity for each human being, from a mild clinical picture that does not require specific care, to severe symptoms that could lead to a series of serious diseases that require intensive respiratory treatment or in the worst cases, death. This situation forces the medical staff to decide if patients are suitable to access the different life support treatments according to the "severity and intensity of the resources", including the use of mechanical ventilators. However, the creation of new medical devices to alleviate this saturation is possible, which is why the construction of low-cost portable ventilators is presented as an important and feasible solution. This document shows the process followed in order to build an assisted mechanical ventilator model. The model was developed based on the research collected during the pandemic by Italian physicians and MIT. This ventilator allows patients with less severe Covid-19 symptoms to be cared for by less experienced healthcare specialists. All this helps while the rest of the resources are used in patients with severe clinical case. In the implementation, a satisfactory operation of the device was obtained in addition to having reduced costs in its construction. Compression of the manual resuscitation bag was achieved by varying the tidal volume, which is designed to vary in a range between 100 and 800 ml. Likewise, the assisted mode has greater precision for tidal volume values between 400 and 500 ml and a RR of 1.2 Brpm | en_US |
dc.format | application/pdf | en_US |
dc.format.extent | 152 páginas | en_US |
dc.language.iso | spa | en_US |
dc.publisher | Universidad de Cuenca | en_US |
dc.relation.ispartofseries | TET;120 | - |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.subject | Electrónica | en_US |
dc.subject | Ventilador mecánico | en_US |
dc.subject | COVID-19 | en_US |
dc.subject | Enfermedad respiratoria | en_US |
dc.subject.other | Dispositivos de ventilación | en_US |
dc.title | Construcción de un ventilador manual invasivo de asistencia mecánica para respiración asistida | en_US |
dc.type | bachelorThesis | en_US |
dc.description.degree | Ingeniero en Electrónica y Telecomunicaciones | en_US |
dc.description.city | Cuenca | en_US |
dc.ucuenca.id | 0301453486 | en_US |
dc.ucuenca.idautor | 0104838008 | en_US |
dc.ucuenca.idautor | 0104273131 | en_US |
dc.ucuenca.version | submittedVersion | en_US |
dc.ucuenca.areaconocimientounescoamplio | 33 Ciencias Tecnológicas | en_US |
dc.ucuenca.correspondencia | pcportilla@gmail.com | en_US |
dc.ucuenca.correspondencia | dmontast@gmail.com | en_US |
dc.ucuenca.areaconocimientounescoespecifico | 3307 Tecnología Electrónica | en_US |
dc.ucuenca.areaconocimientounescodetallado | 2420.08 Virus Respiratorios | en_US |
dc.rights.accessRights | openAccess | en_US |
dc.ucuenca.responsablerecepcion | Salto Morquecho Nube del Rocío | en_US |
Appears in Collections: | Tesis de Pregrado |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Trabajo de Titulación.pdf | Versión presentada (texto completo) | 61.93 MB | Adobe PDF | View/Open |
This item is protected by original copyright |
This item is licensed under a Creative Commons License
Centro de Documentacion Regional "Juan Bautista Vázquez" | ||||||||||
|