dc.description | En este trabajo de titulación se realiza un análisis del impacto eléctrico ante la incorporación del parque eólico Minas de Huascachaca (PEMH) en el Sistema Nacional de Transmisión (SNT) de 138 kV. Se inicia con una breve descripción de los elementos del Sistema Eléctrico de Potencia (SEP) y sus métodos de análisis en estado estacionario equilibrado y desequilibrado. Se prosigue con la descripción técnica de los aerogeneradores y equipos asociados; luego, se realiza un estudio estadístico de la velocidad del viento en el emplazamiento del PEMH, con el objetivo de determinar las velocidades medias y así poder estimar la potencia de salida de los aerogeneradores al momento de la producción de energía eléctrica; la potencia de generación estimada y los datos técnicos del PEMH permiten realizar el análisis en estado estacionario del SEP asociado al PEMH antes y después de la incorporación del mismo para demanda mínima, media y máxima en los periodos secos y lluviosos; para luego realizar el análisis de contingencias N – 1 después de la incorporación PEMH. El trabajo continúa con un estudio de cortocircuitos de las barras asociadas al PEMH; así como la verificación del sistema de protecciones de las líneas adyacentes a la subestación La Paz. Finalizando con las conclusiones y recomendaciones. Todos los cálculos y simulaciones se realizaron a través del software DIgSILENT PowerFactory. | en_US |
dc.description.abstract | In this degree work, an analysis of the electrical impact of the incorporation of the Minas de Huascachaca Wind Farm (MHWF) in the 138 kV National Transmission System (NTS) is carried out. The work begins with a brief description of the elements of the Electrical Power System (EPS) and its balanced and unbalanced steady state analysis methods. It continues with the technical description of the wind turbines and associated equipment; then, a statistical study of the wind speed at the MHWF site is carried out, with the objective of determining the average speeds and thus being able to estimate the output power of the wind turbines at the time of electric energy production; The estimated generation power and the technical data of the MHWF allow performing the steady state analysis of the EPS associated to the MHWF before and after the incorporation of the MHWF for minimum, average and maximum demand in dry and rainy periods; to then perform the analysis of contingencies N – 1 after the incorporation of the MHWF. The work continues with a study of short circuits of the bars associated to the MHWF; as well as the verification of the protection system of the lines adjacent to the La Paz substation. It ends with conclusions and recommendations. All calculations and simulations were performed using DIgSILENT PowerFactory software. | en_US |
dc.format | application/pdf | en_US |
dc.language.iso | spa | en_US |
dc.publisher | Universidad de Cuenca | en_US |
dc.relation.ispartofseries | TE;488 | - |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | * |
dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | * |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
dc.subject | Ingeniería Eléctrica | en_US |
dc.subject | Energía eólica | en_US |
dc.subject | Central eléctrica | en_US |
dc.subject.other | Energía eléctrica | en_US |
dc.title | Análisis en estado estacionario y verificación del sistema de protecciones en las líneas de transmisión de las subestaciones adyacentes ante la incorporación del Parque Eólico Minas de Huascachaca al Sistema Nacional de Transmisión | en_US |
dc.type | bachelorThesis | en_US |
dc.ucuenca.paginacion | 274 páginas | en_US |
dc.description.degree | Ingeniero Eléctrico | en_US |
dc.description.city | Cuenca | en_US |
dc.ucuenca.id | 1400588628 | en_US |
dc.ucuenca.idautor | 0104311006 | en_US |
dc.ucuenca.idautor | 0106079254 | en_US |
dc.ucuenca.areaconocimientounescoamplio | 33 Ciencias Tecnológicas | en_US |
dc.ucuenca.correspondencia | christianmerchan30@yahoo.com | en_US |
dc.ucuenca.correspondencia | pablo199510@hotmail.com | en_US |
dc.ucuenca.areaconocimientounescoespecifico | 3306 Ingeniería y Tecnología Eléctricas | en_US |
dc.ucuenca.areaconocimientounescodetallado | 3306.09 Transmisión y Distribución | en_US |
dc.ucuenca.titulouniforme | Análisis en Estado Estacionario y Verificación del Sistema de Protecciones en las Líneas de Transmisión de las Subestaciones Adyacentes ante la Incorporación del Parque Eólico Minas de Huascachaca al Sistema Nacional de Transmisión | en_US |
dc.rights.accessRights | openAccess | en_US |
dc.ucuenca.responsablerecepcion | Naula Morocho María de Lourdes | en_US |
Appears in Collections: | Tesis de Pregrado |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Trabajo de Titulación.pdf | Versión presentada (texto completo) | 9.44 MB | Adobe PDF | View/Open |
Anexos.pdf | Versión presentada (texto completo) | 16.11 MB | Adobe PDF | View/Open |
This item is protected by original copyright |
This item is licensed under a Creative Commons License
Centro de Documentacion Regional "Juan Bautista Vázquez" | ||||||||||
|