Logo Repositorio Institucional

Please use this identifier to cite or link to this item: http://dspace.ucuenca.edu.ec/handle/123456789/37164
Title: Mathematical modeling and numerical simulation of sulfamethoxazole adsorption onto sugarcane bagasse in a fixed-bed column
Other Titles: 
Authors: Juela Quintuña, Diego Marcelo
Vera Cabezas, Luisa Mayra
Cruzat Contreras, Christian Americo
Alvarez Palomeque, Lourdes Ximena
Vanegas Peña, Maria Eulalia
metadata.dc.ucuenca.correspondencia: Vanegas Peña, Maria Eulalia, eulalia.vanegas@ucuenca.edu.ec
Keywords: Analytical models
Fixed-bed column
Dynamic simulation
Wastewate treatment biosorptio
Breakthrough curve
metadata.dc.ucuenca.areaconocimientofrascatiamplio: 2. Ingeniería y Tecnología
metadata.dc.ucuenca.areaconocimientofrascatidetallado: 2.4.2 Ingeniería de Procesos Químicos
metadata.dc.ucuenca.areaconocimientofrascatiespecifico: 2.4 Ingeniería Química
metadata.dc.ucuenca.areaconocimientounescoamplio: 07 - Ingeniería, Industria y Construcción
metadata.dc.ucuenca.areaconocimientounescodetallado: 0711 - Ingeniería y Procesos Químicos
metadata.dc.ucuenca.areaconocimientounescoespecifico: 071 - Ingeniería y Profesiones Afines
Issue Date: 2021
metadata.dc.ucuenca.volumen: Volumen 280
metadata.dc.source: Chemosphere
metadata.dc.identifier.doi: 10.1016/j.chemosphere.2021.130687
metadata.dc.type: ARTÍCULO
Abstract: 
Having rigorous mathematical models is essential for the design and scaling of adsorption columns. In this study, the dynamic behavior of the sulfamethoxazole adsorption on sugarcane bagasse was studied and compared using analytical models and a theoretical mechanistic model. Initially, fixed-bed column tests were carried out at different flow rates and bed heights. Then, the experimental data were fitted with the most widely used analytical kinetic models, and their fit and fixed-bed parameters were compared with the mechanistic model. Of all analytical models analyzed, the Log-Gompertz model was the one that had the best agreed with experimental data. Although some analytical models fitted the experimental data accurately, their usefulness was questionable. Their parameters did not show a clear relationship with the change in operating conditions, and in certain cases had different behavior from that observed in experimentation. Conversely, the mechanistic model not only predicted the break through curves with great accuracy in the initial and transition stage (R2 > 0.92; SSE < 0.06), but it also estimated relevant parameters. Additionally, the effects of the global mass transfer coefficient (Ki) and the axial dispersion coefficient (Dz) on breakthrough curves were studied using the mechanistic model. Increasing Ki increased the slope of the breakthrough curves with a faster adsorption rate. Similarly, high values of Dz produced lower adsorption capacities of the adsorbent; and it was established that the axial dispersion is relevant in SMX adsorption on SB. The theoretical model presented can be used for the design, scaling, and optimization of adsorption columns.
URI: https://www.sciencedirect.com/science/article/abs/pii/S0045653521011589?via%3Dihub
metadata.dc.ucuenca.urifuente: https://www.sciencedirect.com/journal/chemosphere/vol/280/suppl/C
ISSN: 0045-6535
Appears in Collections:Artículos

Files in This Item:
File Description SizeFormat 
documento.pdfdocument1.55 MBAdobe PDFThumbnail
View/Open


This item is protected by original copyright



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00