Logo Repositorio Institucional

Por favor, use este identificador para citar o enlazar este ítem: http://dspace.ucuenca.edu.ec/handle/123456789/37155
Título : Modeling of residual chlorine in a drinking water network in times of pandemic of the SARS-CoV-2 (COVID-19)
Autor: Garcia Avila, Fausto Fernando
Aviles Añazco, Alex Manuel
Ordoñez Jara, Juan Andres
Guanuchi Quezada, Christian Marcelo
Flores del Pino, Lisveth
Ramos Fernández, Lía
Correspondencia: Garcia Avila, Fausto Fernando, garcia10f@hotmail.com
Palabras clave : Bulk decay constant
COVID-19
Disinfectant
Residual chlorine
Wall decay rate
Área de conocimiento FRASCATI amplio: 1. Ciencias Naturales y Exactas
Área de conocimiento FRASCATI detallado: 1.5.8 Ciencias del Medioambiente
Área de conocimiento FRASCATI específico: 1.5 Ciencias de la Tierra y el Ambiente
Área de conocimiento UNESCO amplio: 05 - Ciencias Físicas, Ciencias Naturales, Matemáticas y Estadísticas
ÁArea de conocimiento UNESCO detallado: 0521 - Ciencias Ambientales
Área de conocimiento UNESCO específico: 052 - Medio Ambiente
Fecha de publicación : 2021
Volumen: Volumen 31, número 12
Fuente: Sustainable Environment Research
metadata.dc.identifier.doi: 10.1186/s42834-021-00084-w
Tipo: ARTÍCULO
Abstract: 
Due to the outbreak of the novel coronavirus disease there is a need for public water supply of the highest quality. Adequate levels of chlorine allow immediate elimination of harmful bacteria and viruses and provide a protective residual throughout the drinking water distribution network (DWDN). Therefore, a residual chlorine decay model was developed to predict chlorine levels in a real drinking water distribution network. The model allowed determining human exposure to drinking water with a deficit of residual chlorine, considering that it is currently necessary for the population to have clean water to combat coronavirus Covid 19. The chlorine bulk decay rates (kb) and the reaction constant of chlorine with the pipe wall (kw) were experimentally determined. Average kb and kw values of 3.7 d− 1 and 0.066m d− 1 were obtained, respectively. The values of kb and kw were used in EPANET to simulate the chlorine concentrations in a DWDN. The residual chlorine concentrations simulated by the properly calibrated and validated model were notably close to the actual concentrations measured at different points of the DWDN. The results showed that maintaining a chlorine concentration of 0.87 mg L− 1 in the distribution tank, the residual chlorine values in the nodes complied with the cuadorian standard (0.3 mg L− 1); meanwhile, about 45% of the nodes did not comply with what is recommended by the WHO as a mechanism to combat the current pandemic (0.5 mg L− 1). This study demonstrated that residual chlorine modeling is a valuable tool for monitoring water quality in the distribution network, allowing to control residual chlorine levels in this pandemic season.
URI : https://sustainenvironres.biomedcentral.com/articles/10.1186/s42834-021-00084-w
URI Fuente: https://sustainenvironres.biomedcentral.com/
ISSN : 2468-2039
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
documento.pdfdocument3 MBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está protegido por copyright original



Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00