Título : Opportunities for improvement in a potabilization plant based on cleaner production: experimental and theoretical investigations
Autor: Cadme Galabay, Manuel Remigio
Garcia Avila, Fausto Fernando
Valdiviezo Gonzales, Lorgio
Iglesias Abad, Sergio Fernando
Zhindon Arevalo, Cesar Edmundo
Gutierrez Ortega, Fausto Horacio
Donoso Moscoso, Silvana Patricia
Correspondencia: Garcia Avila, Fausto Fernando, garcia10f@hotmail.com
Palabras clave : Drinking water treatment plant
Cleaner production options
Coagulant change
Water recirculation
Water saving
Área de conocimiento FRASCATI amplio: 1. Ciencias Naturales y Exactas
Área de conocimiento FRASCATI detallado: 1.5.8 Ciencias del Medioambiente
Área de conocimiento FRASCATI específico: 1.5 Ciencias de la Tierra y el Ambiente
Área de conocimiento UNESCO amplio: 05 - Ciencias Físicas, Ciencias Naturales, Matemáticas y Estadísticas
ÁArea de conocimiento UNESCO detallado: 0521 - Ciencias Ambientales
Área de conocimiento UNESCO específico: 052 - Medio Ambiente
Fecha de publicación : 2021
Volumen: Volumen 11
Fuente: Results in Engineering
metadata.dc.identifier.doi: 10.1016/j.rineng.2021.100274
Tipo: ARTÍCULO
Abstract: 
Cleaner Production (CP) has been studied mainly in the productive sector, ignoring that in drinking water treatment plants (DWTP) a better environmental performance can be achieved. The objective of this study was to evaluate the processes in a DWTP in order to improve production, reduce environmental impact and generate economic savings, for which a cleaner production plan was implementing. The methodology recommended by UNIDO was used. Three CP opportunities were evaluated and identified. After, each CP opportunity, a technical, environmental and economic feasibility analysis was carried out. The results indicated that by implementing the first opportunity of CP (Good housekeeping), it will save water by reducing the number of filter washes by 29400 m3/year, without any investment, so the gains will be immediate. With the second chance of CP, a water-saving of 23256 m3/year will be achieved by recirculating the water from the filters to the decanters. The investment is small, and the recovery period will be 2.4 months. The third CP option, which is based on the coagulant change, would have an annual financial savings of 5361.12 USD, with an immediate payback period. The results showed that the CP applications proposed in this study can significantly reduce water consumption in a WDTP, being able to be implemented in the short and medium-term, without large investments, allowing to address water scarcity today and in the future.
URI : http://dspace.ucuenca.edu.ec/handle/123456789/37131
https://www.sciencedirect.com/science/article/pii/S259012302100075X?via%3Dihub
URI Fuente: https://www.sciencedirect.com/journal/results-in-engineering/vol/11/suppl/C
ISSN : 2590-1230
Aparece en las colecciones: Artículos

Ficheros en este ítem:
Fichero Descripción Tamaño Formato  
documento.pdfdocument871.49 kBAdobe PDFVista previa
Visualizar/Abrir


Este ítem está protegido por copyright original



Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00