Title: Degradation analysis of 5-year field exposed photovoltaic modules using low-cost thermography, electroluminescence and I-V curve tests in Ecuador
Authors: Davila Sacoto, MA
Espinoza Abad, Juan Leonardo
Gonzalez Morales, Luis Gerardo
Hernandez Callejo, Luis
Keywords: Power loss
PV module
Degradation analysis
metadata.dc.ucuenca.areaconocimientofrascatiamplio: 2. Ingeniería y Tecnología
metadata.dc.ucuenca.areaconocimientofrascatidetallado: 2.2.1 Ingeniería Eléctrica y Electrónica
metadata.dc.ucuenca.areaconocimientofrascatiespecifico: 2.2 Ingenierias Eléctrica, Electrónica e Información
metadata.dc.ucuenca.areaconocimientounescoamplio: 07 - Ingeniería, Industria y Construcción
metadata.dc.ucuenca.areaconocimientounescodetallado: 0713 - Electricidad y Energia
metadata.dc.ucuenca.areaconocimientounescoespecifico: 071 - Ingeniería y Profesiones Afines
Issue Date: 2020
metadata.dc.ucuenca.volumen: 2020
metadata.dc.source: SEST 2020 - 3rd International Conference on Smart Energy Systems and Technologies
metadata.dc.identifier.doi: 10.1109/SEST48500.2020.9203333
Publisher: Institute of Electrical and Electronics Engineers Inc.
metadata.dc.description.city: 
Estambul
metadata.dc.type: ARTÍCULO DE CONFERENCIA
Abstract: 
Detection of degradation of photovoltaic (PV) modules is important for the maintenance and operation of solar PV farms to reduce production losses. Infrarred (IR) Thermography, Electroluminescence (EL) and I-V curve tracers are detection techniques that generally use high-cost equipment, which limits their use in developing countries due to the tight budgets they manage for research and development. This study shows the use of low-cost alternatives to determine the deterioration of 140 solar PV modules at the University of Cuenca-Ecuador. This array has functioned continually without fail for 5 years. Measurement equipment for degradation detection techniques with a cost of less than 1, 000.00USD is used and its application is validated with professional equipment. A power loss of 1.29% per year is obtained. In addition, the use of degradation values obtained from similar studies is proposed to reduce the effort of detecting deterioration modes, whose approximation allows the calculation of the power delivered by the installation with a 2.04% error. A method for the economic quantification due to the losses caused by the deterioration of solar PV modules is also exposed.
URI: http://dspace.ucuenca.edu.ec/handle/123456789/35462
https://www.scopus.com/record/display.uri?eid=2-s2.0-85093694472&doi=10.1109%2fSEST48500.2020.9203333&origin=inward&txGid=5f45f398bb1ad739d6e8d37ac45f62e9
metadata.dc.ucuenca.urifuente: https://ieeexplore.ieee.org/xpl/conhome/9199229/proceeding
ISBN: 978-172814701-7
ISSN: 0000-0000
Appears in Collections:Artículos

Files in This Item:
File Description SizeFormat 
documento.pdfdocument209.92 kBAdobe PDFThumbnail
View/Open


This item is protected by original copyright



Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

 

Centro de Documentacion Regional "Juan Bautista Vázquez"

Biblioteca Campus Central Biblioteca Campus Salud Biblioteca Campus Yanuncay
Av. 12 de Abril y Calle Agustín Cueva, Telf: 4051000 Ext. 1311, 1312, 1313, 1314. Horario de atención: Lunes-Viernes: 07H00-21H00. Sábados: 08H00-12H00 Av. El Paraíso 3-52, detrás del Hospital Regional "Vicente Corral Moscoso", Telf: 4051000 Ext. 3144. Horario de atención: Lunes-Viernes: 07H00-19H00 Av. 12 de Octubre y Diego de Tapia, antiguo Colegio Orientalista, Telf: 4051000 Ext. 3535 2810706 Ext. 116. Horario de atención: Lunes-Viernes: 07H30-19H00